Features
1. 9.7-inch color touch LCD screen,easy to operate,display all parameters and histograms on the same screen.
2. Fewer samples are required for testing: whole blood≤12μl, pre-diluted≤20μl.
3. 60 samples/hour.
4. 21 parameters +3 histograms.
5. It can be turned on continuously for 24 hours.
6. Automaticall clean the sampler,counting pool and pipeline after startingup
7. Buit-in thermal printer,external printer can be connected.
8. Electrical impedance method,cyanide-free detection of HGB.
9. Fully intelligent blockage removal and alarm function.
10. Both automatic calibration and manual calibration are available.
11. Counting Mode:Venous,capilary,prediluted.
12. Support LIS system.
Technical Specifications
Model |
BK-3200 |
|||||
Throughput |
60 samples/hour |
|||||
Principle |
Impedance for WBC differentiation and WBC/RBC/PLT count;Colorimetric method for HGB |
|||||
Channels |
2 |
|||||
Parameters |
21 parameters(including WBC,Mid#,Lym#,Gran#,Mid%,Lym%,Gran%,RBC,HGB,HCT, MCV,MCH,MCHC,RDW-SD,RDW-CV,PLT,MPV,PDW,PCT,P-LCR,P-LCC) |
|||||
Histograms |
3 histograms (including WBC,RBC,PLT histograms) |
|||||
Sample Volume |
Whole blood:12μl,Prediluted:20μl |
|||||
Calibration |
Manual,auto calibration |
|||||
Counting Modes |
Venous,capilary,prediluted |
|||||
Printing Model |
Auto print,manual print |
|||||
LIS |
Support Bi-directional LIS |
|||||
Language |
Chinese,English,Spanish,French,Russian,Ukrainian |
|||||
Reagent |
Diluent 10L,Hemolytic agent 250ml,Probe cleanser:50ml |
|||||
Data Input |
9.7-inch touch screen,mouse,keyboard (optional) |
|||||
Output |
Internal printer,support external printer |
|||||
Printer Paper |
57*30mm |
|||||
Interface |
4 USB ports,network port,RS232 serial port |
|||||
Storage |
100.000 results with histogram |
|||||
Unclog |
High voltage burn,reverse high-pressure flush |
|||||
Work Temperature |
15-30℃ |
|||||
Power Supply |
100-240 AC,50/60Hz,150VA |
|||||
Relative Humidity |
30%~85% |
|||||
Atmospheric Pressure |
70.0kPa-110.0kPa |
|||||
Carry-Over Rate |
Parameter |
WRC |
RBC |
HGB |
PLT |
|
CV |
≤ 1.5% |
≤ 1% |
≤ 1% |
≤3% |
||
Background |
Parameter |
WBC |
RBC |
HGB |
HCT |
PLT |
Background |
≤ 0.03*109/L |
≤ 0.03*1012/L |
≤1g/L |
≤0.5% |
≤10*109/L |
|
Linearity |
Parameter |
Measurement range |
CV |
|||
WBC |
(0.5~10.00*109)/L (10.10~99.9*109)/L |
(±0.5*109)/L ±5% |
||||
RBC |
(0.05~1.00*1012)/L (1.01~9.99*1012)/L |
(±0.05*1012)/L ±5% |
||||
HGB |
(2~70g)/L (71~300.0g)/L |
(±2.0g)/L ±2% |
||||
PLT |
(10~100*109)/L (101~999*109)/L |
(±10.0*109)/L ±8% |
||||
Precision |
Paiameter |
Repeatabilit |
Measurement range |
|||
WBC |
≤6.0% |
(3.5~9.5×109)/L |
||||
RBC |
≤3.0% |
(3.8~5.8×1012)/L |
||||
HGB |
≤2.5% |
(415~175g)/L |
||||
PLT |
≤10.0% |
(125-350×109)/L |
||||
HCT |
≤3.0% |
35%~50% |
||||
External Size(W*D*H) |
295*467*418mm |
|||||
Packed Size(W*D*H) |
Instrument:404*564*616mm; Reagent:340*340*340mm |
|||||
Net Weight |
19 kg |
|||||
Gross Weight |
Instrument:31kg; Reagent:13 kg |
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.