The C-Reactive Protein Control is a high-quality, lyophilized product designed for use in clinical laboratories to monitor the performance of CRP assays. It provides consistent and reliable results, ensuring the accuracy of CRP measurements in human whole blood samples. The control is available in two concentrations, catering to different testing needs and ensuring comprehensive quality control across a range of CRP levels.
1. The C-Reactive Protein Control is characterized by its stability and consistency, making it an essential tool for laboratories. Its lyophilized form ensures long shelf life and easy reconstitution, while the inclusion of a preservative maintains the integrity of the control over time.
2. The control is composed of recombinant CRP antigen and a preservative (P300) at 0.1%. It is available in two concentrations: Level 1 (3.5-6.5 mg/L) and Level 2 (70-130 mg/L). Each control is reconstituted with 1 mL of purified or deionized water, ensuring accurate and reproducible results.
3. This control is specifically designed for internal quality control of CRP testing in human whole blood samples. It is used to monitor the performance of CRP assays on applicable instruments, ensuring the accuracy and reliability of clinical diagnostics.
The C-Reactive Protein Control, also known as CRP Control, is a reliable and essential tool for clinical laboratories. Its lyophilized form and inclusion of a preservative ensure stability and consistency, while its two concentration levels cater to a wide range of testing needs. This control is indispensable for ensuring the accuracy of CRP measurements in clinical diagnostics.
The C-Reactive Protein Control offers reliable and consistent performance for CRP testing in clinical laboratories. Its key features include stability, ease of use, and comprehensive quality control across different CRP levels.
1. The control provides stable and consistent results, ensuring the accuracy of CRP measurements in clinical diagnostics. Its lyophilized form ensures long shelf life and easy reconstitution.
2. The inclusion of a preservative (P300) at 0.1% maintains the integrity of the control over time, ensuring reliable performance throughout its shelf life.
3. The control is available in two concentrations: Level 1 (3.5-6.5 mg/L) and Level 2 (70-130 mg/L), catering to different testing needs and ensuring comprehensive quality control.
4. Each control is reconstituted with 1 mL of purified or deionized water, ensuring accurate and reproducible results. The product includes a single target value for each level.
5. The control is specifically designed for internal quality control of CRP testing in human whole blood samples, ensuring the accuracy and reliability of clinical diagnostics.
The C-Reactive Protein Control is a reliable and essential tool for clinical laboratories. Its stability, ease of use, and comprehensive quality control across different CRP levels make it indispensable for ensuring the accuracy of CRP measurements in clinical diagnostics.
The C-Reactive Protein Control is widely used in clinical laboratories for internal quality control of CRP testing. It ensures the accuracy and reliability of CRP measurements in human whole blood samples.
1. The control is used to monitor the performance of CRP assays on applicable instruments, ensuring the accuracy and reliability of clinical diagnostics.
2. It is particularly useful in laboratories that perform high-volume CRP testing, providing consistent and reliable results across different testing platforms.
3. The control is also used in research settings to validate new CRP assays and ensure the accuracy of experimental results.
4. In clinical diagnostics, the control is used to ensure the accuracy of CRP measurements in patients with inflammatory conditions, such as rheumatoid arthritis and cardiovascular disease.
5. The control is also used in quality assurance programs to ensure the accuracy and reliability of CRP testing across different laboratories and testing platforms.
The C-Reactive Protein Control is an essential tool for clinical laboratories, ensuring the accuracy and reliability of CRP testing in human whole blood samples. Its use in internal quality control, research, and quality assurance programs makes it indispensable for clinical diagnostics.
The C-Reactive Protein Control is a high-quality product designed for use in clinical laboratories. When purchasing, consider product parameters, types, budget, and usage scenarios to ensure the best fit for your laboratory's needs.
1. Product parameters: The control is available in two concentrations: Level 1 (3.5-6.5 mg/L) and Level 2 (70-130 mg/L). Each control is reconstituted with 1 mL of purified or deionized water and includes a single target value for each level.
2. Product types: The control is available in lyophilized form, ensuring long shelf life and easy reconstitution. It is suitable for use in a wide range of CRP testing platforms.
3. Budget: Consider the cost of the control and its shelf life when budgeting for your laboratory. The control's long shelf life and consistent performance make it a cost-effective choice for quality control.
4. Usage scenarios: The control is suitable for use in clinical laboratories, research settings, and quality assurance programs. Ensure that the control is compatible with your laboratory's testing platforms and procedures.
When purchasing the C-Reactive Protein Control, consider product parameters, types, budget, and usage scenarios to ensure the best fit for your laboratory's needs. The control's long shelf life, consistent performance, and compatibility with a wide range of testing platforms make it a cost-effective choice for quality control.
When using the C-Reactive Protein Control, it is important to follow proper handling and storage procedures to ensure accurate and reliable results.
1. Store the control at the recommended temperature to maintain its stability and integrity. Avoid exposure to extreme temperatures or direct sunlight.
2. Reconstitute the control with 1 mL of purified or deionized water, ensuring accurate and reproducible results. Do not use other solvents or diluents.
3. Handle the control with care to avoid contamination. Use sterile techniques when reconstituting and handling the control.
4. Follow the manufacturer's instructions for use and storage to ensure the accuracy and reliability of the control. Do not use the control beyond its expiration date.
5. Dispose of the control and any waste materials in accordance with local regulations and laboratory protocols.
Proper handling and storage of the C-Reactive Protein Control are essential for ensuring accurate and reliable results. Follow the manufacturer's instructions and laboratory protocols to maintain the integrity of the control and ensure the accuracy of CRP measurements.