Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
C-Reactive Protein Assay Kit (Immunoturbidimetric Method)
The C-Reactive Protein Assay Kit is composed of two main reagents. Reagent 1 includes Tris-HCl buffer and polyethylene glycol 6000, while Reagent 2 contains anti-human CRP antibody, Tris-HCl buffer, and bovine serum albumin. These components work together to ensure accurate and reliable measurement of CRP levels in human serum.
Product English Name:
C-Reactive Protein Assay Kit (Immunoturbidimetric Method)
Alias:
CRP Assay Kit,Immunoturbidimetric CRP Kit
Intended Use:
This kit is designed for the in vitro quantitative determination of C-reactive protein (CRP) levels in human serum. CRP is a key biomarker for inflammation and infection, making this kit essential for clinical diagnostics and research.
Product Introduction

The C-Reactive Protein Assay Kit (Immunoturbidimetric Method) is a highly sensitive and specific tool for measuring CRP levels in human serum. It is widely used in clinical laboratories to assess inflammation and monitor disease progression. The kit offers a reliable and efficient method for CRP quantification, making it a valuable asset in both diagnostic and research settings.

1. The kit features a robust immunoturbidimetric method, ensuring high accuracy and precision in CRP measurement. Its sensitivity allows for the detection of even low levels of CRP, which is crucial for early diagnosis and monitoring of inflammatory conditions.
2. The composition of the kit includes two reagents: Reagent 1, which contains Tris-HCl buffer and polyethylene glycol 6000, and Reagent 2, which includes anti-human CRP antibody, Tris-HCl buffer, and bovine serum albumin. These components are carefully formulated to ensure optimal performance and stability.
3. The primary use of this kit is for the quantitative determination of CRP in human serum. CRP is a key biomarker for inflammation, and its levels are often elevated in response to infection, injury, or chronic diseases. This kit is essential for clinical diagnostics, research, and monitoring of therapeutic interventions.

The C-Reactive Protein Assay Kit, also known as the CRP Assay Kit, is a vital tool in clinical diagnostics. Its immunoturbidimetric method ensures accurate CRP measurement, while its carefully formulated reagents guarantee reliable performance. Whether you're diagnosing inflammation or monitoring disease progression, this kit is an indispensable resource.

Main Features

The C-Reactive Protein Assay Kit offers high sensitivity and specificity for CRP measurement. Its immunoturbidimetric method ensures accurate results, making it a reliable choice for clinical diagnostics and research.

1. High Sensitivity: The kit can detect even low levels of CRP, making it ideal for early diagnosis and monitoring of inflammatory conditions.
2. Specificity: The anti-human CRP antibody ensures that the measurement is specific to CRP, reducing the risk of cross-reactivity with other proteins.
3. Stability: The reagents are formulated to maintain stability over time, ensuring consistent performance throughout the kit's shelf life.
4. Ease of Use: The kit is designed for straightforward operation, allowing for quick and efficient CRP measurement in clinical laboratories.
5. Versatility: The kit can be used in a variety of settings, including hospitals, research institutions, and diagnostic laboratories.

The C-Reactive Protein Assay Kit stands out for its high sensitivity, specificity, and ease of use. Whether you're in a clinical lab or a research setting, this kit offers reliable and accurate CRP measurement, making it a must-have tool for diagnosing and monitoring inflammation.

Clinical Applications

The C-Reactive Protein Assay Kit is widely used in clinical settings to diagnose and monitor inflammatory conditions. Its accurate measurement of CRP levels is crucial for assessing disease progression and therapeutic efficacy.

1. Diagnosis of Inflammation: The kit is used to measure CRP levels in patients with suspected inflammatory conditions, aiding in the diagnosis of diseases such as rheumatoid arthritis and lupus.
2. Monitoring Disease Progression: CRP levels are monitored over time to assess the progression of chronic inflammatory diseases and the effectiveness of treatment.
3. Infection Detection: Elevated CRP levels can indicate the presence of bacterial or viral infections, making the kit useful in diagnosing and managing infectious diseases.
4. Cardiovascular Risk Assessment: CRP is a marker for cardiovascular risk, and the kit is used to assess the risk of heart disease in patients.
5. Research Applications: The kit is also used in research settings to study the role of CRP in various diseases and to develop new therapeutic interventions.

The C-Reactive Protein Assay Kit is a versatile tool in clinical diagnostics, used for diagnosing inflammation, monitoring disease progression, and assessing cardiovascular risk. Its accurate measurement of CRP levels makes it indispensable in both clinical and research settings.

Purchasing Guide

When purchasing the C-Reactive Protein Assay Kit, consider factors such as product specifications, types, budget, and intended use to ensure you select the right kit for your needs.

1. Product Specifications: Review the kit's specifications, including sensitivity, specificity, and shelf life, to ensure it meets your requirements.
2. Product Types: Choose between different types of CRP assay kits based on your specific needs, such as high-sensitivity kits for research or standard kits for routine clinical use.
3. Budget: Consider your budget when selecting a kit, balancing cost with the need for high-quality, reliable performance.
4. Intended Use: Determine the primary use of the kit, whether for clinical diagnostics, research, or both, to ensure you select the most appropriate product.

Selecting the right C-Reactive Protein Assay Kit involves careful consideration of product specifications, types, budget, and intended use. By taking these factors into account, you can ensure that you choose a kit that meets your needs and delivers reliable performance.

 Precautions

Proper handling and storage of the C-Reactive Protein Assay Kit are essential to ensure accurate results and maintain the integrity of the reagents.

1. Storage Conditions: Store the kit at the recommended temperature to maintain the stability and performance of the reagents.
2. Handling: Follow proper handling procedures to avoid contamination and ensure accurate results.
3. Expiration Date: Always check the expiration date before use to ensure the reagents are still effective.
4. Calibration: Regularly calibrate the equipment used with the kit to maintain accuracy and precision.
5. Disposal: Dispose of used reagents and materials according to local regulations to ensure safety and environmental compliance.

To get the most out of your C-Reactive Protein Assay Kit, it's crucial to follow proper storage, handling, and disposal procedures. By adhering to these precautions, you can ensure accurate results and maintain the integrity of the reagents, making your diagnostic and research efforts more effective.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files