Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
C-Reactive Protein (CRP) Assay Kit (Immunoturbidimetric Method)
The C-Reactive Protein (CRP) Assay Kit consists of two main reagents and an optional calibrator. Reagent 1 contains a phosphate buffer (20mmol/L), polyethylene glycol 6000 (3-4%), and a surfactant (0.5g/L). Reagent 2 includes a phosphate buffer (20mmol/L), goat anti-human CRP polyclonal antibody (15%), and a preservative (0.1%). The optional calibrator is composed of CRP antigen, phosphate buffer, and bovine serum albumin. Note: Components from different batches are not interchangeable. The kit is traceable to the NIBSC CRP standard (NIBSC code: 85/506).
Product English Name:
C-Reactive Protein (CRP) Assay Kit (Immunoturbidimetric Method)
Alias:
CRP Test Kit,Immunoturbidimetric CRP Kit
Intended Use:
This kit is designed for the quantitative in vitro determination of C-reactive protein (CRP) levels in human serum. It is primarily used to aid in the diagnosis of acute inflammation and coronary artery diseases, providing critical insights into patient health and treatment strategies.
Product Introduction

The C-Reactive Protein (CRP) Assay Kit is a sophisticated diagnostic tool used to measure CRP levels in human serum. CRP is a key biomarker for inflammation and infection, making this kit essential for clinical diagnostics. The kit employs the immunoturbidimetric method, ensuring high sensitivity and accuracy. It is widely used in hospitals and laboratories to monitor inflammatory conditions and assess cardiovascular risks.

1. The kit features a highly sensitive immunoturbidimetric method, which ensures precise measurement of CRP levels. This method is known for its reliability and consistency in clinical settings.
2. The kit's composition includes two main reagents and an optional calibrator. Reagent 1 contains a phosphate buffer, polyethylene glycol, and a surfactant, while Reagent 2 includes a phosphate buffer, goat anti-human CRP antibody, and a preservative. The optional calibrator is made of CRP antigen, phosphate buffer, and bovine serum albumin.
3. The primary use of this kit is to quantitatively determine CRP levels in human serum, aiding in the diagnosis of acute inflammation and coronary artery diseases. It is an invaluable tool for clinicians to assess patient health and guide treatment decisions.

The C-Reactive Protein (CRP) Assay Kit, also known as the CRP Test Kit, is a vital diagnostic tool in modern medicine. Its ability to accurately measure CRP levels makes it indispensable for diagnosing and monitoring inflammatory and cardiovascular conditions. The kit's robust design and reliable performance ensure that it meets the high standards required in clinical diagnostics.

Main Features

The CRP Assay Kit offers high sensitivity and accuracy in measuring CRP levels, making it a reliable tool for clinical diagnostics. Its immunoturbidimetric method ensures consistent results, and the kit is easy to use, with clear instructions and stable reagents.

1. High Sensitivity: The kit's immunoturbidimetric method ensures that even low levels of CRP can be detected, providing early indications of inflammation or infection.
2. Accuracy: The kit is designed to deliver precise measurements, reducing the risk of false positives or negatives in diagnostic results.
3. Ease of Use: With clear instructions and stable reagents, the kit is user-friendly, making it suitable for both experienced and novice laboratory technicians.
4. Stability: The reagents are formulated to remain stable under various storage conditions, ensuring consistent performance over time.
5. Traceability: The kit is traceable to the NIBSC CRP standard, ensuring that measurements are consistent with international standards.

The CRP Assay Kit stands out for its high sensitivity, accuracy, and ease of use. Its robust design and reliable performance make it a trusted tool in clinical diagnostics, providing critical insights into patient health and guiding effective treatment strategies.

Clinical Applications

The CRP Assay Kit is widely used in clinical settings to diagnose and monitor inflammatory conditions and cardiovascular diseases. Its ability to provide accurate CRP measurements makes it an essential tool for patient care.

1. Acute Inflammation: The kit is used to detect elevated CRP levels, which are indicative of acute inflammation, helping clinicians to diagnose and monitor conditions such as infections and autoimmune diseases.
2. Cardiovascular Diseases: Elevated CRP levels are associated with an increased risk of coronary artery disease. The kit aids in assessing cardiovascular risks and guiding treatment decisions.
3. Post-Surgical Monitoring: The kit is used to monitor CRP levels in patients post-surgery to detect any signs of infection or inflammation.
4. Chronic Diseases: The kit is also used in the management of chronic inflammatory conditions, such as rheumatoid arthritis, to monitor disease activity and response to treatment.
5. Research Applications: Beyond clinical diagnostics, the kit is used in research settings to study the role of CRP in various diseases and to develop new therapeutic strategies.

The CRP Assay Kit is a versatile tool in clinical practice, used for diagnosing and monitoring a range of inflammatory and cardiovascular conditions. Its accuracy and reliability make it an indispensable asset in patient care and medical research.

Purchasing Guide

When purchasing the CRP Assay Kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your clinical or research needs.

1. Product Specifications: Review the kit's specifications, including sensitivity, accuracy, and stability, to ensure it meets your diagnostic requirements.
2. Product Types: Choose between different kit types based on your specific needs, such as kits with or without calibrators, or those designed for high-throughput testing.
3. Budget: Consider your budget and compare prices from different suppliers to find a kit that offers the best value without compromising on quality.
4. Intended Use: Ensure the kit is suitable for your intended use, whether for clinical diagnostics, research, or both, and that it complies with relevant regulatory standards.

Purchasing the CRP Assay Kit requires careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can select a kit that best meets your clinical or research needs, ensuring accurate and reliable CRP measurements.

 Precautions

Proper handling and storage of the CRP Assay Kit are essential to ensure accurate results and maintain reagent stability. Follow all instructions carefully to avoid contamination and ensure reliable performance.

1. Storage Conditions: Store the kit at the recommended temperature to maintain reagent stability. Avoid exposure to extreme temperatures or direct sunlight.
2. Handling: Use aseptic techniques when handling reagents to prevent contamination. Always wear appropriate personal protective equipment (PPE).
3. Calibration: Regularly calibrate the kit using the provided calibrators to ensure accurate measurements. Follow the calibration instructions precisely.
4. Expiration Date: Do not use reagents or components past their expiration date, as this may affect the accuracy and reliability of the results.
5. Disposal: Dispose of used reagents and materials according to local regulations and biohazard waste disposal guidelines to ensure safety and environmental compliance.

The CRP Assay Kit requires careful handling and storage to ensure accurate and reliable results. By following proper procedures for storage, handling, calibration, and disposal, you can maintain the kit's performance and ensure the safety of laboratory personnel.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files