CRP/SAA Dual Detection Kit (Quantum Dot Fluorescence Immunochromatography)
The kit consists of a detection card, sample diluent, and an ID or IC card. The detection card includes a test strip and a plastic card. The test strip contains a nitrocellulose membrane coated with CRP/SAA monoclonal antibodies and rabbit IgG, a sample pad with quantum dot-conjugated CRP/SAA monoclonal antibodies and quantum dot-conjugated anti-rabbit IgG, absorbent paper, and a PVC backing. The sample diluent is a phosphate buffer solution.
Product English Name:
CRP/SAA Dual Detection Kit (Quantum Dot Fluorescence Immunochromatography)
Alias:
CRP/SAA Combo Kit,Inflammation Marker Kit
Intended Use:
This kit is designed for the in vitro quantitative detection of C-reactive protein (CRP) and serum amyloid A (SAA) concentrations in human whole blood, serum, plasma, and capillary blood. It is primarily used as a non-specific inflammatory marker in clinical settings.
Product Introduction

The CRP/SAA Dual Detection Kit utilizes quantum dot fluorescence immunochromatography to provide accurate and rapid quantification of CRP and SAA levels. This kit is essential for diagnosing and monitoring inflammatory conditions, offering a reliable tool for healthcare professionals.

1. The kit features a highly sensitive detection mechanism using quantum dots, which enhances the accuracy and speed of the test results.
2. The structure includes a nitrocellulose membrane and a sample pad, both crucial for the binding and detection of CRP and SAA antibodies.
3. It is used in clinical laboratories to assess inflammation levels, aiding in the diagnosis and management of various inflammatory diseases.

The CRP/SAA Dual Detection Kit is a sophisticated tool that combines advanced quantum dot technology with immunochromatography to detect inflammation markers efficiently. Its design and functionality make it a valuable asset in clinical diagnostics.

Main Features

This kit offers rapid, accurate, and sensitive detection of CRP and SAA, crucial for assessing inflammatory responses.

1. High sensitivity due to quantum dot fluorescence, ensuring precise detection of low analyte concentrations.
2. Rapid results, typically within minutes, facilitating timely clinical decisions.
3. Easy-to-use format with minimal sample preparation required.
4. Compatible with various sample types including whole blood, serum, plasma, and capillary blood.
5. Includes an ID or IC card for easy data management and tracking.

The CRP/SAA Dual Detection Kit stands out for its quick and accurate detection capabilities, making it an indispensable tool in the fast-paced clinical environment.

Clinical Applications

Clinically, this kit is used to monitor and diagnose inflammatory conditions, providing essential data for patient management.

1. Used in emergency settings to quickly assess inflammation levels in patients.
2. Helps in the diagnosis of infections, autoimmune diseases, and other inflammatory conditions.
3. Monitors the effectiveness of anti-inflammatory treatments.
4. Useful in research settings for studying inflammatory biomarkers.
5. Assists in the management of chronic diseases where inflammation is a key factor.

The clinical applications of the CRP/SAA Dual Detection Kit are vast, ranging from emergency diagnostics to chronic disease management, highlighting its versatility and importance in healthcare.

Purchasing Guide

This guide provides essential information for purchasing the CRP/SAA Dual Detection Kit, focusing on product specifications and usage scenarios.

1. Product parameters include sensitivity, specificity, and compatibility with various sample types.
2. Available in different types to suit various laboratory needs and budgets.
3. Budget considerations should include the cost per test and the potential for bulk discounts.
4. Usage scenarios range from small clinics to large hospitals, each with specific needs and capacities.

When purchasing the CRP/SAA Dual Detection Kit, it's crucial to consider the specific needs of your facility, including the types of tests you'll be conducting and your budget constraints.

 Precautions

Proper handling and storage of the CRP/SAA Dual Detection Kit are essential to maintain its efficacy and ensure accurate results.

1. Store the kit at recommended temperatures to preserve the integrity of the reagents.
2. Handle all components with care to avoid contamination and ensure accurate test results.
3. Follow the manufacturer's instructions precisely for sample preparation and testing procedures.
4. Dispose of used materials according to biohazard waste disposal guidelines.
5. Regularly calibrate and maintain equipment used with the kit to ensure consistent performance.

Adhering to the recommended precautions when using the CRP/SAA Dual Detection Kit is vital for achieving reliable and accurate diagnostic results, ensuring patient safety and effective treatment outcomes.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files