B-type Natriuretic Peptide Assay Kit (Chemiluminescence Method)
The B-type Natriuretic Peptide Assay Kit consists of 30 disposable reagent strips and 3 calibrators. Each strip includes magnetic bead-coated particles, acridinium-labeled conjugates, and pre-trigger solution. The magnetic bead-coated particles contain B-type natriuretic peptide antibodies (mouse-derived) with protein stabilizers and preservatives. The acridinium-labeled conjugates also contain B-type natriuretic peptide antibodies with protein stabilizers and preservatives. The pre-trigger solution is an acidic solution containing hydrogen peroxide. The calibrators include three vials with varying concentrations of B-type natriuretic peptide, protein stabilizers, and preservatives.
Product English Name:
B-type Natriuretic Peptide Assay Kit (Chemiluminescence Method)
Alias:
BNP Assay Kit,BNP Test Kit
Intended Use:
This kit is used for the quantitative determination of B-type natriuretic peptide (BNP) in human plasma and whole blood. It is primarily used in clinical settings for the auxiliary diagnosis of heart failure.
Product Introduction

The B-type Natriuretic Peptide Assay Kit is a chemiluminescence-based diagnostic tool designed for the accurate measurement of BNP levels in human blood. BNP is a critical biomarker for heart failure, and this kit provides a reliable method for its detection. The kit includes disposable reagent strips and calibrators, ensuring ease of use and consistent results. Its high sensitivity and specificity make it an essential tool in clinical diagnostics.

1. The kit features a chemiluminescence method, which offers high sensitivity and specificity for BNP detection. This method ensures accurate and reliable results, even at low concentrations of BNP.
2. The kit is composed of 30 disposable reagent strips and 3 calibrators. Each strip contains magnetic bead-coated particles, acridinium-labeled conjugates, and pre-trigger solution, all designed to work together for precise BNP measurement.
3. The primary use of this kit is in the clinical diagnosis of heart failure. By measuring BNP levels in plasma or whole blood, healthcare providers can assess the severity of heart failure and monitor patient response to treatment.

The B-type Natriuretic Peptide Assay Kit, also known as the BNP Assay Kit, is a vital tool in the clinical diagnosis of heart failure. Its high sensitivity and specificity, combined with its ease of use, make it an indispensable resource for healthcare professionals. The kit's composition, including disposable reagent strips and calibrators, ensures consistent and reliable results, aiding in the accurate assessment of patient conditions.

Main Features

The B-type Natriuretic Peptide Assay Kit offers high sensitivity and specificity for BNP detection, making it a reliable tool for clinical diagnostics. Its chemiluminescence method ensures accurate results, even at low BNP concentrations.

1. The kit utilizes a chemiluminescence method, which provides high sensitivity and specificity for BNP detection. This method ensures accurate results, even at low concentrations of BNP.
2. The disposable reagent strips are designed for single-use, reducing the risk of contamination and ensuring consistent results. Each strip contains all necessary components for BNP measurement.
3. The kit includes three calibrators with varying concentrations of BNP, allowing for precise calibration and accurate measurement across a wide range of BNP levels.
4. The magnetic bead-coated particles and acridinium-labeled conjugates in the reagent strips are optimized for high binding efficiency, ensuring reliable and reproducible results.
5. The pre-trigger solution in the reagent strips is formulated to enhance the chemiluminescence reaction, providing a strong and stable signal for accurate BNP measurement.

The B-type Natriuretic Peptide Assay Kit is a highly sensitive and specific diagnostic tool, essential for the accurate measurement of BNP levels. Its chemiluminescence method, combined with disposable reagent strips and precise calibrators, ensures reliable and consistent results. This kit is a valuable resource for healthcare professionals in the diagnosis and management of heart failure.

Clinical Applications

The B-type Natriuretic Peptide Assay Kit is primarily used in clinical settings for the diagnosis and monitoring of heart failure. It provides accurate measurement of BNP levels, aiding in patient assessment and treatment planning.

1. The kit is used in hospitals and clinics for the diagnosis of heart failure. By measuring BNP levels, healthcare providers can assess the severity of the condition and determine appropriate treatment strategies.
2. In emergency settings, the kit is used to quickly assess patients presenting with symptoms of heart failure. Rapid BNP measurement helps in making timely and informed clinical decisions.
3. The kit is also used in outpatient settings for the ongoing monitoring of patients with chronic heart failure. Regular BNP measurements help in tracking disease progression and response to treatment.
4. In research settings, the kit is used to study the role of BNP in various cardiovascular conditions. Its high sensitivity and specificity make it a valuable tool for clinical research.
5. The kit is also used in conjunction with other diagnostic tools to provide a comprehensive assessment of a patient's cardiovascular health. It complements imaging and other laboratory tests for a more complete diagnosis.

The B-type Natriuretic Peptide Assay Kit is a versatile tool in clinical practice, used for the diagnosis and monitoring of heart failure. Its ability to provide accurate and rapid BNP measurements makes it invaluable in emergency, outpatient, and research settings. The kit's reliability and ease of use ensure that healthcare providers can make informed decisions for patient care.

Purchasing Guide

When purchasing the B-type Natriuretic Peptide Assay Kit, consider factors such as product specifications, types, budget, and intended use. Ensure that the kit meets your clinical or research needs.

1. Product specifications: Ensure that the kit includes all necessary components, such as reagent strips and calibrators, and that it meets the required sensitivity and specificity for BNP detection.
2. Product types: Choose the appropriate kit type based on your intended use, whether for clinical diagnostics, research, or both. Consider the volume of tests you will be performing.
3. Budget: Determine your budget for the kit, taking into account the cost per test and the overall value provided by the kit's features and reliability.
4. Intended use: Consider the specific clinical or research applications for which you will be using the kit. Ensure that it is suitable for your intended use and that it meets any regulatory requirements.

Purchasing the B-type Natriuretic Peptide Assay Kit requires careful consideration of product specifications, types, budget, and intended use. By selecting a kit that meets your specific needs, you can ensure accurate and reliable BNP measurements for clinical or research purposes.

 Precautions

When using the B-type Natriuretic Peptide Assay Kit, it is important to follow proper handling and storage procedures to ensure accurate results and maintain the integrity of the components.

1. Storage: Store the kit at the recommended temperature to maintain the stability of the reagents. Avoid exposure to extreme temperatures or direct sunlight.
2. Handling: Handle the reagent strips and calibrators with care to avoid contamination. Use gloves and follow aseptic techniques when preparing and using the kit.
3. Calibration: Ensure that the calibrators are properly reconstituted and used according to the instructions. Accurate calibration is essential for reliable BNP measurement.
4. Expiration: Check the expiration date of the kit before use. Do not use expired components, as this may affect the accuracy of the results.
5. Disposal: Dispose of used reagent strips and other components according to local regulations for biohazardous waste. Follow proper disposal procedures to ensure safety.

Proper handling, storage, and disposal of the B-type Natriuretic Peptide Assay Kit are essential for maintaining the accuracy and reliability of BNP measurements. By following the recommended precautions, you can ensure the integrity of the kit and obtain consistent results for clinical or research use.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files