6-Plex Cytokine Detection Kit (Multiplex Microsphere Flow Cytometric Immunofluorescence Assay)
The kit consists of two main components: the detection component and the optional calibration component. The detection component includes capture microsphere antibodies, detection antibodies, SA-PE, assay buffer, and wash buffer (10×). The optional calibration component includes calibrators, matrix B, and assay buffer. The capture microsphere antibodies target IL-4, IL-6, IL-10, IL-17, IFN-γ, and TNF-α. The detection antibodies are biotin-labeled for IL-4, IL-6, IL-10, IL-17, IFN-γ, and TNF-α. SA-PE is streptavidin-phycoerythrin conjugate. The assay buffer contains BSA in phosphate buffer, and the wash buffer contains Tween-20 in phosphate buffer.
Product English Name:
6-Plex Cytokine Detection Kit (Multiplex Microsphere Flow Cytometric Immunofluorescence Assay)
Alias:
Cytokine Assay Kit,Multiplex Cytokine Detection Kit
Intended Use:
This kit is designed for the quantitative detection of IL-4, IL-6, IL-10, IL-17, IFN-γ, and TNF-α in human plasma. It is used in research and clinical settings to measure cytokine levels, which are critical for understanding immune responses and inflammatory conditions.
Product Introduction

The 6-Plex Cytokine Detection Kit is a state-of-the-art tool for simultaneously measuring six key cytokines in human plasma. Utilizing multiplex microsphere flow cytometric immunofluorescence technology, this kit offers high sensitivity and specificity. It is widely used in immunology research, clinical diagnostics, and drug development to assess immune system activity and monitor disease progression.

1. The kit features a multiplex design, allowing for the simultaneous detection of six cytokines, which enhances efficiency and reduces sample volume requirements.
2. The capture microsphere antibodies are specifically designed to bind to their respective cytokines, ensuring accurate and reliable detection. The detection antibodies are biotin-labeled, and the SA-PE conjugate provides a strong fluorescent signal for quantification.
3. The kit is used in various applications, including research on immune responses, clinical diagnostics for inflammatory diseases, and monitoring therapeutic interventions.

The 6-Plex Cytokine Detection Kit is a versatile and reliable tool for researchers and clinicians. Its ability to simultaneously measure multiple cytokines makes it invaluable for understanding complex immune responses and diagnosing inflammatory conditions.

Main Features

The 6-Plex Cytokine Detection Kit offers high sensitivity, specificity, and multiplexing capability, making it ideal for cytokine profiling in research and clinical settings.

1. High sensitivity: The kit can detect low concentrations of cytokines, making it suitable for research and clinical applications where precise measurements are required.
2. Multiplexing capability: The ability to measure six cytokines simultaneously reduces the need for multiple assays, saving time and resources.
3. Specificity: The capture microsphere antibodies are highly specific to their target cytokines, ensuring accurate results.
4. Ease of use: The kit includes all necessary components and detailed instructions, making it user-friendly.
5. Versatility: The kit can be used in various applications, including research, clinical diagnostics, and drug development.

The 6-Plex Cytokine Detection Kit is a powerful tool for cytokine profiling, offering high sensitivity, specificity, and multiplexing capability. Its ease of use and versatility make it a valuable asset in both research and clinical settings.

Clinical Applications

The 6-Plex Cytokine Detection Kit is widely used in clinical research and diagnostics to measure cytokine levels, which are critical for understanding immune responses and inflammatory diseases.

1. Research applications: The kit is used in immunology research to study the role of cytokines in immune responses and disease mechanisms.
2. Clinical diagnostics: It is used to diagnose and monitor inflammatory diseases, such as rheumatoid arthritis and inflammatory bowel disease.
3. Drug development: The kit is used to assess the efficacy of new drugs targeting cytokine pathways.
4. Patient monitoring: It is used to monitor cytokine levels in patients undergoing immunotherapy or other treatments.
5. Biomarker discovery: The kit is used in biomarker discovery studies to identify cytokine profiles associated with specific diseases.

The 6-Plex Cytokine Detection Kit is a valuable tool in clinical research and diagnostics, providing critical insights into immune responses and inflammatory diseases. Its applications in research, diagnostics, and drug development make it an essential tool for understanding and treating complex diseases.

Purchasing Guide

This guide provides essential information for purchasing the 6-Plex Cytokine Detection Kit, including product specifications, types, budget considerations, and usage scenarios.

1. Product specifications: The kit includes all necessary components for cytokine detection, with optional calibration components available.
2. Product types: The kit is available in different formats, including single-use and bulk options, to meet various research and clinical needs.
3. Budget considerations: The cost of the kit varies depending on the format and quantity purchased. Bulk purchases may offer cost savings.
4. Usage scenarios: The kit is suitable for use in research laboratories, clinical diagnostics, and pharmaceutical development.

The 6-Plex Cytokine Detection Kit is a versatile and cost-effective solution for cytokine detection. Its various formats and optional components make it suitable for a wide range of applications, from research to clinical diagnostics.

 Precautions

Proper handling and storage of the 6-Plex Cytokine Detection Kit are essential to ensure accurate results and maintain the integrity of the components.

1. Storage conditions: Store the kit at the recommended temperature to maintain the stability of the components.
2. Handling: Use aseptic techniques to avoid contamination of the samples and reagents.
3. Calibration: Ensure that the calibration components are properly prepared and used according to the instructions.
4. Disposal: Dispose of used materials according to local regulations and guidelines.
5. Training: Ensure that all users are properly trained in the use of the kit and associated equipment.

Proper handling, storage, and disposal of the 6-Plex Cytokine Detection Kit are crucial for obtaining accurate and reliable results. Following the recommended precautions will help ensure the success of your experiments and maintain the integrity of the kit components.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files