The Disposable Triple-Row Stapler is a medical device designed for use in gastrointestinal surgeries. It is engineered to provide a secure and efficient method for anastomosis, ensuring minimal tissue trauma and optimal healing. The device is available in various sizes and types to accommodate different surgical needs.
1. The Disposable Triple-Row Stapler features a triple-row staple configuration, which enhances the strength and reliability of the anastomosis. This design reduces the risk of leakage and promotes faster healing.
2. The device consists of several key components: staples, an anvil, a body, and a cutting assembly. The anvil and cutting assembly work together to create a precise and clean cut, while the staples ensure a secure closure of the tissue.
3. The primary use of this stapler is in gastrointestinal surgeries, where it is employed to reconnect sections of the digestive tract. Its versatility allows it to be used in various types of anastomosis, making it a valuable tool in surgical procedures.
The Disposable Triple-Row Stapler, also known as the Triple-Row Surgical Stapler, is a highly effective tool for gastrointestinal surgeries. Its triple-row staple configuration and precise cutting mechanism make it a reliable choice for surgeons. The device is available in multiple sizes and types, ensuring it can meet the diverse needs of different surgical procedures.
The Disposable Triple-Row Stapler is designed to provide a secure and efficient method for anastomosis in gastrointestinal surgeries. Its key features include a triple-row staple configuration, precise cutting mechanism, and availability in various sizes and types.
1. The triple-row staple configuration ensures a strong and reliable anastomosis, reducing the risk of leakage and promoting faster healing.
2. The precise cutting mechanism allows for a clean and accurate cut, minimizing tissue trauma and ensuring optimal surgical outcomes.
3. The device is available in multiple sizes, ranging from 14mm to 32mm, to accommodate different surgical needs and patient anatomies.
4. The product is provided in a sterile condition, sterilized by Cobalt-60 irradiation, ensuring safety and reducing the risk of infection.
5. The Disposable Triple-Row Stapler is designed for single use, eliminating the need for reprocessing and reducing the risk of cross-contamination.
The Disposable Triple-Row Stapler is a versatile and reliable tool for gastrointestinal surgeries. Its triple-row staple configuration, precise cutting mechanism, and availability in various sizes make it a valuable asset in the operating room. The device's single-use design ensures safety and reduces the risk of infection, making it a preferred choice for surgeons.
The Disposable Triple-Row Stapler is widely used in clinical settings for gastrointestinal surgeries, including esophageal, gastric, and intestinal anastomosis. Its design ensures secure and efficient tissue closure, promoting optimal healing.
1. In esophageal surgeries, the stapler is used to reconnect sections of the esophagus, ensuring a secure and leak-proof anastomosis.
2. In gastric surgeries, the device is employed to create a secure connection between the stomach and other parts of the digestive tract, facilitating proper digestion and nutrient absorption.
3. In intestinal surgeries, the stapler is used to reconnect sections of the intestine, ensuring proper function and reducing the risk of complications.
4. The device is also used in bariatric surgeries, where it helps create a secure anastomosis in patients undergoing weight loss procedures.
5. The Disposable Triple-Row Stapler is a valuable tool in emergency surgeries, where quick and reliable tissue closure is essential for patient survival.
The Disposable Triple-Row Stapler is a crucial tool in various gastrointestinal surgeries, including esophageal, gastric, and intestinal procedures. Its ability to create a secure and efficient anastomosis makes it a preferred choice for surgeons. The device's versatility and reliability ensure optimal outcomes in both elective and emergency surgeries.
When purchasing the Disposable Triple-Row Stapler, it is important to consider factors such as product specifications, types, budget, and intended use. This guide provides essential information to help make an informed decision.
1. Product specifications: The stapler is available in 10 different sizes, ranging from 14mm to 32mm. It is important to select the appropriate size based on the surgical procedure and patient anatomy.
2. Product types: The device is available in two types: Type A (basic) and Type B (improved). Type B offers enhanced features and is recommended for more complex surgeries.
3. Budget considerations: The cost of the stapler varies depending on the type and size. It is important to balance budget constraints with the need for a reliable and effective device.
4. Intended use: The stapler is designed for single use in gastrointestinal surgeries. It is essential to ensure that the device is compatible with the specific surgical procedure and patient needs.
Purchasing the Disposable Triple-Row Stapler requires careful consideration of product specifications, types, budget, and intended use. By selecting the appropriate size and type, and balancing budget constraints, healthcare providers can ensure they acquire a reliable and effective device for their surgical needs.
When using the Disposable Triple-Row Stapler, it is important to follow proper handling and usage guidelines to ensure patient safety and optimal surgical outcomes. This section outlines key precautions to consider.
1. Ensure the device is used within its expiration date and stored in a sterile environment to prevent contamination.
2. Follow the manufacturer's instructions for proper assembly and use of the stapler to avoid malfunctions during surgery.
3. Verify the correct size and type of stapler for the specific surgical procedure and patient anatomy to ensure a secure anastomosis.
4. Monitor the patient for any signs of complications, such as leakage or infection, following the use of the stapler.
5. Dispose of the stapler properly after use, following local regulations for medical waste disposal to prevent cross-contamination.
Using the Disposable Triple-Row Stapler requires adherence to proper handling and usage guidelines to ensure patient safety and optimal surgical outcomes. By following the manufacturer's instructions, verifying the correct size and type, and monitoring for complications, healthcare providers can minimize risks and ensure successful surgeries.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.