Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
Full-Range C-Reactive Protein (CRP) Detection Kit (Time-Resolved Fluorescence Immunochromatography)
The kit includes a detection card, sample diluent, calibration card or QR code, capillary (compatible with dry fluorescence immunoanalyzers TFL-1000 and TFL-1600), dropper (compatible with TFL-1000 and TFL-1600), and an instruction manual. The detection card consists of a sample pad, conjugate pad, nitrocellulose membrane (coated with time-resolved fluorescent microspheres labeled with mouse anti-human CRP antibody, 0.01μg-1.00μg per test), T-line coated with mouse anti-human CRP antibody (0.10μg-1.00μg per test), C-line coated with goat anti-mouse immunoglobulin antibody (0.10μg-1.00μg per test), absorbent pad, backing card, and plastic casing. The sample diluent primarily contains 0.02 mol/L PBS buffer with a pH of 7.4±0.2.
Product English Name:
Full-Range C-Reactive Protein (CRP) Detection Kit (Time-Resolved Fluorescence Immunochromatography)
Alias:
CRP Detection Kit,Fluorescence CRP Assay Kit
Intended Use:
This product is designed for the in vitro quantitative detection of C-reactive protein (CRP) levels in human serum, plasma, or whole blood. It is widely used in clinical settings to assess inflammation and monitor conditions such as infections, autoimmune diseases, and cardiovascular risks.
Product Introduction

The Full-Range C-Reactive Protein (CRP) Detection Kit utilizes time-resolved fluorescence immunochromatography to provide accurate and reliable quantitative measurements of CRP levels. This kit is essential for diagnosing and monitoring inflammatory conditions, offering high sensitivity and specificity. It is compatible with specific dry fluorescence immunoanalyzers, ensuring seamless integration into laboratory workflows.

1. The kit features a detection card with a multi-layered structure, including a sample pad, conjugate pad, nitrocellulose membrane, absorbent pad, and plastic casing. Each component is meticulously designed to ensure precise and consistent results.
2. The detection card's nitrocellulose membrane is coated with time-resolved fluorescent microspheres and specific antibodies, enabling the accurate capture and measurement of CRP levels. The sample diluent, composed of a PBS buffer, ensures optimal sample preparation.
3. This kit is primarily used for quantitative CRP detection in human serum, plasma, or whole blood. It is a critical tool for diagnosing inflammatory conditions, monitoring disease progression, and evaluating treatment efficacy.

The Full-Range CRP Detection Kit is a sophisticated tool designed for precise and reliable CRP measurement. Its advanced fluorescence immunochromatography technology, combined with a well-structured detection card, ensures high accuracy and ease of use. Whether you're diagnosing inflammation or monitoring treatment, this kit is an indispensable resource in clinical settings.

Main Features

The CRP Detection Kit offers high sensitivity, specificity, and compatibility with specific immunoanalyzers, making it a reliable choice for CRP quantification.

1. High sensitivity: The kit can detect CRP levels as low as 0.01μg, ensuring accurate results even at low concentrations.
2. Specificity: The use of time-resolved fluorescent microspheres and specific antibodies minimizes cross-reactivity, providing reliable measurements.
3. Compatibility: Designed for use with TFL-1000 and TFL-1600 dry fluorescence immunoanalyzers, the kit integrates seamlessly into laboratory workflows.
4. Ease of use: The kit includes a detailed instruction manual and pre-calibrated components, simplifying the testing process.
5. Versatility: Suitable for serum, plasma, and whole blood samples, the kit accommodates various clinical needs.

The CRP Detection Kit stands out for its precision, ease of use, and adaptability. Its advanced features make it a trusted choice for clinicians and researchers alike, ensuring accurate CRP measurements in diverse clinical scenarios.

Clinical Applications

This kit is widely used in clinical settings to diagnose and monitor inflammatory conditions, infections, autoimmune diseases, and cardiovascular risks.

1. Diagnosis of infections: The kit helps identify bacterial and viral infections by measuring elevated CRP levels.
2. Monitoring autoimmune diseases: Regular CRP testing aids in tracking disease activity and treatment response in conditions like rheumatoid arthritis.
3. Cardiovascular risk assessment: Elevated CRP levels are associated with increased cardiovascular risk, making this kit valuable for preventive care.
4. Post-surgical monitoring: CRP levels are monitored post-surgery to detect infections or complications.
5. Research applications: The kit is used in clinical studies to investigate the role of CRP in various diseases.

The CRP Detection Kit is a versatile tool in clinical practice, aiding in the diagnosis and management of a wide range of conditions. Its applications extend from routine patient care to advanced research, making it an essential resource for healthcare professionals.

Purchasing Guide

This guide provides essential information for purchasing the CRP Detection Kit, including product specifications, types, budget considerations, and usage scenarios.

1. Product specifications: Ensure compatibility with TFL-1000 or TFL-1600 immunoanalyzers and verify the kit's sensitivity and specificity.
2. Product types: Choose between standard and high-sensitivity kits based on your clinical needs.
3. Budget considerations: Evaluate the cost per test and overall value to align with your laboratory's budget.
4. Usage scenarios: Consider the kit's application in routine diagnostics, research, or specialized clinical settings.

Purchasing the CRP Detection Kit requires careful consideration of compatibility, sensitivity, and budget. By understanding your specific needs and the kit's features, you can make an informed decision that enhances your laboratory's capabilities.

 Precautions

Proper handling and storage of the CRP Detection Kit are essential to ensure accurate results and user safety.

1. Storage conditions: Store the kit at 2-8°C and avoid freezing to maintain reagent stability.
2. Handling precautions: Use gloves and follow standard laboratory safety protocols to prevent contamination.
3. Sample preparation: Ensure samples are properly collected and processed according to the instruction manual.
4. Equipment calibration: Regularly calibrate the immunoanalyzer to ensure accurate readings.
5. Disposal: Dispose of used components according to local regulations for biohazardous waste.

The CRP Detection Kit requires careful handling and storage to maintain its performance and ensure user safety. By adhering to these precautions, you can achieve reliable results and protect both your samples and your laboratory environment.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files