Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
Disposable J-Type Ureteral Catheter (Ureteral Stent Kit)
The Disposable J-Type Ureteral Catheter (Ureteral Stent Kit) consists of a catheter, pusher tube, guidewire, guidewire sheath, connector, and clips (Robert clip, umbilical clip, and flat clip). The guidewire, pusher tube, guidewire sheath, and clips are auxiliary instruments and are optional. The connector is available in a single J-type configuration. The catheter is made of radiopaque polyurethane (TPU), the pusher tube is made of polypropylene (PP), the guidewire sheath is made of specialized polyethylene (PE), and the guidewire is made of stainless steel with a coating. The product comes in 2 models based on the J-type catheter structure and 12 sizes based on the catheter's outer diameter. It is sterilized using ethylene oxide and is intended for single-use only.
Product English Name:
Disposable J-Type Ureteral Catheter (Ureteral Stent Kit)
Alias:
Ureteral Stent,J-Type Catheter
Intended Use:
The Disposable J-Type Ureteral Catheter is used to provide stenting and drainage between the renal pelvis and the bladder through minimally invasive or open surgical procedures. It is designed to maintain urinary flow and prevent obstruction in the ureter.
Product Introduction

The Disposable J-Type Ureteral Catheter (Ureteral Stent Kit) is a medical device designed for temporary or long-term ureteral stenting. It is used to ensure proper urine drainage from the kidney to the bladder, particularly in cases of ureteral obstruction or after surgical procedures. The kit includes a catheter, pusher tube, guidewire, and other optional components, all made from high-quality materials to ensure safety and effectiveness. The product is sterilized and intended for single-use, minimizing the risk of infection.

1. The Disposable J-Type Ureteral Catheter is characterized by its J-shaped design, which provides secure placement and reduces the risk of migration. The catheter is made from radiopaque polyurethane, allowing for easy visualization under X-ray. The kit includes optional auxiliary instruments such as a guidewire, pusher tube, and clips, which enhance the ease of insertion and placement.
2. The catheter is constructed from biocompatible materials, including polyurethane for the catheter body, polypropylene for the pusher tube, and polyethylene for the guidewire sheath. The guidewire is made of stainless steel with a coating to reduce friction during insertion. The product is available in multiple sizes and models to accommodate different patient anatomies and clinical needs.
3. The primary use of the Disposable J-Type Ureteral Catheter is to provide stenting and drainage in the ureter. It is commonly used in urological procedures to treat conditions such as ureteral obstruction, kidney stones, and post-surgical recovery. The catheter ensures continuous urine flow, preventing complications such as hydronephrosis and infection.

The Disposable J-Type Ureteral Catheter, also known as the Ureteral Stent, is a versatile and essential tool in urological procedures. Its J-shaped design and high-quality materials ensure secure placement and effective drainage. Whether used in minimally invasive or open surgeries, this catheter provides reliable support for patients with ureteral obstructions or post-surgical needs.

Main Features

The Disposable J-Type Ureteral Catheter offers secure placement, effective drainage, and ease of use. Its radiopaque material allows for clear visualization, and the optional auxiliary instruments enhance procedural efficiency.

1. The J-shaped design of the catheter ensures secure placement within the ureter, reducing the risk of migration and dislodgement. This design is particularly beneficial in maintaining proper positioning during patient movement.
2. The catheter is made from radiopaque polyurethane, which allows for easy visualization under X-ray or fluoroscopy. This feature is crucial for accurate placement and monitoring during and after the procedure.
3. The kit includes optional auxiliary instruments such as a guidewire, pusher tube, and clips, which facilitate smooth insertion and placement of the catheter. These components are designed to work seamlessly with the catheter, enhancing procedural efficiency.
4. The catheter is available in multiple sizes and models, allowing healthcare providers to choose the most appropriate option based on patient anatomy and clinical requirements. This flexibility ensures optimal performance and patient comfort.
5. The product is sterilized using ethylene oxide and is intended for single-use only, minimizing the risk of infection and ensuring patient safety. The disposable nature of the catheter also reduces the need for reprocessing and storage.

The Disposable J-Type Ureteral Catheter stands out for its secure J-shaped design, radiopaque material, and optional auxiliary instruments. These features make it a reliable choice for urological procedures, ensuring effective drainage and patient safety. Its availability in multiple sizes and models further enhances its versatility and suitability for various clinical scenarios.

Clinical Applications

The Disposable J-Type Ureteral Catheter is widely used in urological procedures to treat ureteral obstructions, kidney stones, and post-surgical recovery. It ensures continuous urine flow and prevents complications such as hydronephrosis and infection.

1. The catheter is commonly used in the treatment of ureteral obstructions caused by kidney stones, tumors, or strictures. It provides a temporary or long-term solution to maintain urine flow and prevent kidney damage.
2. In cases of kidney stones, the catheter is used to facilitate the passage of stones and reduce pain and discomfort. It can be placed before or after procedures such as lithotripsy to ensure proper drainage.
3. The catheter is also used in post-surgical recovery, particularly after ureteral reimplantation or other urological surgeries. It helps to maintain ureteral patency and prevent complications such as leakage or stricture formation.
4. In patients with hydronephrosis, the catheter is used to relieve pressure in the kidney by ensuring continuous urine flow. This helps to prevent further kidney damage and improve patient outcomes.
5. The catheter is also used in palliative care for patients with advanced cancer or other conditions that cause ureteral obstruction. It provides relief from symptoms and improves quality of life.

The Disposable J-Type Ureteral Catheter plays a crucial role in urological care, from treating kidney stones to aiding post-surgical recovery. Its ability to maintain urine flow and prevent complications makes it an indispensable tool in both acute and chronic urological conditions. Whether used in emergency settings or long-term care, this catheter ensures patient comfort and safety.

Purchasing Guide

When purchasing the Disposable J-Type Ureteral Catheter, consider factors such as product specifications, types, budget, and intended use. Proper selection ensures optimal performance and patient outcomes.

1. Product specifications, including catheter size, model, and material, should be carefully evaluated to ensure compatibility with patient anatomy and clinical needs. The catheter is available in 12 sizes and 2 models, providing flexibility for different scenarios.
2. The type of catheter, whether standard or with additional features such as radiopaque markers, should be selected based on the specific requirements of the procedure. The optional auxiliary instruments, such as the guidewire and pusher tube, should also be considered.
3. Budget considerations are important, as the cost of the catheter and its optional components can vary. However, the focus should be on quality and suitability rather than cost alone, as the catheter plays a critical role in patient care.
4. The intended use of the catheter, whether for temporary stenting, long-term drainage, or post-surgical recovery, should guide the selection process. The catheter should be chosen based on its ability to meet the specific clinical needs of the patient.

Selecting the right Disposable J-Type Ureteral Catheter involves careful consideration of product specifications, types, budget, and intended use. By focusing on these factors, healthcare providers can ensure that they choose a catheter that meets the needs of their patients and provides optimal outcomes. The availability of multiple sizes and models, along with optional auxiliary instruments, makes this catheter a versatile and reliable choice for urological procedures.

 Precautions

Proper handling and use of the Disposable J-Type Ureteral Catheter are essential to ensure patient safety and optimal outcomes. Key precautions include sterilization, proper insertion techniques, and monitoring for complications.

1. The catheter is intended for single-use only and should not be reused or reprocessed. Reuse can lead to infection and other complications. Ensure that the product is properly sterilized before use.
2. Proper insertion techniques should be followed to avoid damage to the ureter or surrounding tissues. The use of auxiliary instruments such as the guidewire and pusher tube can facilitate smooth insertion.
3. Monitor the patient for signs of complications such as infection, migration, or blockage. Regular follow-up and imaging may be necessary to ensure proper placement and function of the catheter.
4. The catheter should be removed or replaced as recommended by the healthcare provider. Prolonged use can lead to complications such as encrustation or infection.
5. Proper disposal of the catheter and its components is essential to prevent contamination and ensure environmental safety. Follow local regulations for medical waste disposal.

The Disposable J-Type Ureteral Catheter requires careful handling and use to ensure patient safety and optimal outcomes. From proper sterilization to monitoring for complications, each step is crucial in minimizing risks and maximizing the benefits of this essential urological tool. By following these precautions, healthcare providers can ensure that the catheter is used effectively and safely in a variety of clinical scenarios.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files