Type IV Collagen (CIV) Calibrator
The Type IV Collagen (CIV) Calibrator is available in two configurations: a two-point set and a six-point set. The two-point set includes high (H) and low (L) concentration calibrators, with CIV antigen concentrations of 900.0 ng/mL and 250.0 ng/mL, respectively. The six-point set includes six concentration points (A-F) with CIV antigen concentrations ranging from 0 ng/mL to 2400 ng/mL. Both sets are formulated in a Tris-HCl buffer (150 mmol/L, pH 7.5) containing 0.5% BSA and 0.05% Proclin 300.
Product English Name:
Type IV Collagen (CIV) Calibrator
Alias:
CIV Calibrator,Collagen IV Calibration Standard
Intended Use:
The CIV Calibrator is designed for use with the Type IV Collagen (CIV) Detection Kit (Magnetic Particle Chemiluminescence Method) and compatible instruments from Jiangsu Zecheng Biotechnology Co., Ltd. or Taizhou Zecheng Biotechnology Co., Ltd. It is used for the calibration of CIV detection activities, ensuring accurate and reliable measurement of CIV levels in various samples.
Product Introduction

The Type IV Collagen (CIV) Calibrator is an essential tool for ensuring the accuracy and reliability of CIV detection assays. It is specifically designed to work with the CIV Detection Kit and compatible instruments, providing a standardized reference for calibration. The calibrator is available in two configurations, offering flexibility for different laboratory needs. Its precise formulation and concentration range make it a reliable choice for laboratories aiming to achieve consistent and accurate results in CIV detection.

1. The CIV Calibrator is characterized by its high precision and stability, ensuring consistent performance across different batches and instruments. The inclusion of BSA and Proclin 300 in the buffer enhances the stability of the calibrator, making it suitable for long-term storage and use.
2. The composition of the CIV Calibrator includes a Tris-HCl buffer with specific concentrations of BSA and Proclin 300, which are critical for maintaining the stability and functionality of the CIV antigen. The two-point and six-point configurations provide a range of concentrations to suit various calibration needs.
3. The primary use of the CIV Calibrator is to calibrate CIV detection assays, ensuring that the measurements are accurate and reliable. It is specifically designed to work with the CIV Detection Kit and compatible instruments, making it an indispensable tool for laboratories focused on CIV research and diagnostics.

The Type IV Collagen (CIV) Calibrator, also known as the CIV Calibrator or Collagen IV Calibration Standard, is a meticulously designed product that plays a crucial role in the accurate detection of CIV. Its two-point and six-point configurations offer flexibility, while its precise formulation ensures stability and reliability. This calibrator is an essential component for any laboratory engaged in CIV research or diagnostics, providing a standardized reference that enhances the accuracy of results.

Main Features

The CIV Calibrator is designed to provide precise and reliable calibration for CIV detection assays. Its key features include high stability, a wide concentration range, and compatibility with specific detection kits and instruments.

1. High Stability: The inclusion of BSA and Proclin 300 in the buffer ensures that the calibrator remains stable over time, even under varying storage conditions.
2. Wide Concentration Range: The two-point and six-point configurations offer a broad range of CIV antigen concentrations, allowing for flexible calibration options.
3. Compatibility: The calibrator is specifically designed to work with the CIV Detection Kit and compatible instruments, ensuring seamless integration into existing workflows.
4. Precision: The precise formulation of the calibrator ensures that it provides consistent and accurate results, reducing variability in CIV detection assays.
5. Ease of Use: The calibrator is easy to prepare and use, making it a convenient choice for laboratories with varying levels of expertise.

The CIV Calibrator stands out for its high stability, wide concentration range, and compatibility with specific detection kits and instruments. Its precision and ease of use make it an invaluable tool for laboratories aiming to achieve accurate and reliable CIV detection results. Whether you're working with a two-point or six-point configuration, this calibrator ensures that your assays are consistently calibrated to the highest standards.

Clinical Applications

The CIV Calibrator is widely used in clinical settings for the accurate detection and measurement of Type IV Collagen (CIV). It is particularly valuable in research and diagnostics related to fibrosis, cancer, and other conditions where CIV levels are indicative of disease progression.

1. Fibrosis Research: The CIV Calibrator is used in research studies to measure CIV levels in tissues, helping to understand the progression of fibrosis and evaluate potential treatments.
2. Cancer Diagnostics: In cancer diagnostics, the calibrator is used to measure CIV levels in blood or tissue samples, providing insights into tumor growth and metastasis.
3. Clinical Trials: The calibrator is used in clinical trials to ensure that CIV detection assays are accurately calibrated, providing reliable data for evaluating new therapies.
4. Routine Diagnostics: In routine clinical diagnostics, the CIV Calibrator is used to ensure that CIV levels are accurately measured, aiding in the diagnosis and monitoring of various diseases.
5. Quality Control: The calibrator is also used in quality control processes to ensure that CIV detection assays are performing consistently and accurately over time.

The CIV Calibrator is a versatile tool in clinical applications, particularly in fibrosis research, cancer diagnostics, and clinical trials. Its ability to provide accurate and reliable CIV measurements makes it an essential component in the diagnosis and monitoring of various diseases. Whether used in research or routine diagnostics, this calibrator ensures that CIV detection assays are consistently calibrated to the highest standards.

Purchasing Guide

When purchasing the CIV Calibrator, it is important to consider factors such as product specifications, types, budget, and intended use to ensure that the calibrator meets your laboratory's needs.

1. Product Specifications: Consider the concentration range and configuration (two-point or six-point) that best suits your laboratory's calibration needs.
2. Product Types: Choose between the two-point and six-point configurations based on the range of concentrations required for your assays.
3. Budget: Evaluate the cost of the calibrator in relation to your laboratory's budget, ensuring that you are getting the best value for your investment.
4. Intended Use: Consider the specific applications for which the calibrator will be used, such as research, diagnostics, or quality control, to ensure that it meets your requirements.

Purchasing the CIV Calibrator requires careful consideration of product specifications, types, budget, and intended use. By taking these factors into account, you can ensure that the calibrator you choose will meet your laboratory's needs and provide reliable calibration for your CIV detection assays. Whether you opt for the two-point or six-point configuration, this calibrator is a valuable investment for any laboratory focused on accurate CIV measurement.

 Precautions

When using the CIV Calibrator, it is important to follow proper handling and storage procedures to ensure the accuracy and reliability of your results.

1. Storage: Store the calibrator at the recommended temperature to maintain its stability and performance. Avoid exposure to extreme temperatures or direct sunlight.
2. Handling: Handle the calibrator with care to avoid contamination. Use sterile techniques when preparing and using the calibrator.
3. Preparation: Follow the manufacturer's instructions for preparing the calibrator, ensuring that it is properly mixed and ready for use.
4. Usage: Use the calibrator within the specified time frame to ensure accurate results. Do not use expired or improperly stored calibrator.
5. Disposal: Dispose of used calibrator and related materials according to local regulations and laboratory protocols to ensure safety and compliance.

Proper handling and storage of the CIV Calibrator are essential for maintaining its performance and ensuring accurate results. By following the recommended procedures for storage, handling, preparation, usage, and disposal, you can maximize the effectiveness of the calibrator and minimize the risk of errors in your CIV detection assays. Always adhere to the manufacturer's guidelines and local regulations to ensure safe and compliant use of the calibrator.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files