Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
Type III Procollagen N-Terminal Peptide Assay Kit (Chemiluminescent Immunoassay)
The kit consists of several components: Reagent R1 contains biotinylated anti-Type III Procollagen N-Terminal Peptide monoclonal antibody (approximately 200ng/mL, murine-derived) in a protein buffer with 0.1% Proclin300. Reagent R2 includes acridinium ester-labeled anti-Type III Procollagen N-Terminal Peptide monoclonal antibody (approximately 200ng/mL, murine-derived) in a protein buffer with 0.1% Proclin300. Reagent M contains streptavidin-coated magnetic particles (approximately 0.4mg/mL) treated with preservatives. Calibrators 1, 2, and 3 contain human-derived Type III Procollagen N-Terminal Peptide at concentrations of 10ng/mL, 40ng/mL, and 20ng/mL, respectively, in a protein buffer with 0.1% Proclin300.
Product English Name:
Type III Procollagen N-Terminal Peptide Assay Kit (Chemiluminescent Immunoassay)
Alias:
PⅢNP Assay Kit,Collagen III Peptide Test Kit
Intended Use:
This kit is designed for the in vitro quantitative detection of Type III Procollagen N-Terminal Peptide (PⅢNP) concentration in human serum. It is primarily used in clinical settings to assess liver fibrosis and other conditions related to collagen metabolism.
Product Introduction

The Type III Procollagen N-Terminal Peptide Assay Kit is a sophisticated diagnostic tool used in clinical laboratories to measure the concentration of PⅢNP in human serum. This kit employs a chemiluminescent immunoassay method, which is known for its high sensitivity and specificity. It is particularly useful in diagnosing and monitoring liver fibrosis, as PⅢNP levels are indicative of collagen synthesis and degradation processes.

1. The kit features a highly sensitive chemiluminescent immunoassay method, ensuring accurate and reliable results. It is designed to detect even low concentrations of PⅢNP, making it suitable for early diagnosis and monitoring of liver fibrosis.
2. The kit's composition includes biotinylated and acridinium ester-labeled monoclonal antibodies, which specifically bind to PⅢNP. The use of magnetic particles coated with streptavidin enhances the assay's efficiency and precision.
3. The primary use of this kit is in clinical diagnostics, particularly for assessing liver health. By measuring PⅢNP levels, healthcare providers can gain insights into collagen metabolism and the progression of liver fibrosis.

The Type III Procollagen N-Terminal Peptide Assay Kit, also known as the PⅢNP Assay Kit, is a vital tool in clinical diagnostics. Its high sensitivity and specificity make it indispensable for monitoring liver fibrosis and other collagen-related conditions. The kit's unique composition and advanced methodology ensure accurate and reliable results, aiding healthcare providers in making informed decisions.

Main Features

The main features of this kit include its high sensitivity, specificity, and the use of advanced chemiluminescent immunoassay technology. It is designed for accurate and reliable detection of PⅢNP in human serum.

1. High Sensitivity: The kit can detect low concentrations of PⅢNP, making it suitable for early diagnosis and monitoring of liver fibrosis.
2. Specificity: The use of monoclonal antibodies ensures that the assay specifically targets PⅢNP, reducing the risk of cross-reactivity with other proteins.
3. Advanced Technology: The chemiluminescent immunoassay method provides rapid and accurate results, enhancing the efficiency of clinical diagnostics.
4. Comprehensive Calibration: The kit includes multiple calibrators, allowing for precise quantification of PⅢNP levels across a wide range of concentrations.
5. User-Friendly: The kit is designed for ease of use, with clear instructions and minimal preparation required, making it accessible to a wide range of laboratory personnel.

The Type III Procollagen N-Terminal Peptide Assay Kit stands out for its high sensitivity, specificity, and advanced technology. These features make it an essential tool in clinical diagnostics, particularly for monitoring liver fibrosis. The kit's user-friendly design and comprehensive calibration ensure accurate and reliable results, supporting healthcare providers in their diagnostic efforts.

Clinical Applications

This kit is widely used in clinical settings for the diagnosis and monitoring of liver fibrosis. It is also employed in research studies related to collagen metabolism and other conditions where PⅢNP levels are indicative of disease progression.

1. Liver Fibrosis Diagnosis: The kit is primarily used to assess liver fibrosis by measuring PⅢNP levels, which are indicative of collagen synthesis and degradation.
2. Monitoring Disease Progression: Regular monitoring of PⅢNP levels helps healthcare providers track the progression of liver fibrosis and adjust treatment plans accordingly.
3. Research Applications: The kit is also used in research studies to investigate the role of collagen metabolism in various diseases, including liver fibrosis and other connective tissue disorders.
4. Clinical Trials: The kit is employed in clinical trials to evaluate the efficacy of new treatments for liver fibrosis and other collagen-related conditions.
5. Patient Management: By providing accurate and reliable PⅢNP measurements, the kit aids in the management of patients with liver fibrosis, ensuring timely and appropriate interventions.

The Type III Procollagen N-Terminal Peptide Assay Kit is a versatile tool in clinical diagnostics and research. Its primary application is in the diagnosis and monitoring of liver fibrosis, but it is also used in research studies and clinical trials. The kit's ability to provide accurate and reliable PⅢNP measurements supports healthcare providers in managing patients and advancing medical research.

Purchasing Guide

When purchasing this kit, it is important to consider product specifications, types, budget, and intended use. This guide provides essential information to help you make an informed decision.

1. Product Specifications: Ensure that the kit meets your laboratory's requirements in terms of sensitivity, specificity, and detection range. Verify the composition and concentration of reagents and calibrators.
2. Product Types: The kit is available in different formats, including single-use and multi-use options. Choose the type that best suits your laboratory's workflow and testing volume.
3. Budget Considerations: Evaluate the cost of the kit in relation to its features and benefits. Consider the long-term value and potential savings from accurate and reliable results.
4. Intended Use: Determine the primary application of the kit, whether for clinical diagnostics, research, or clinical trials. Ensure that the kit is suitable for your specific needs and intended use.

Purchasing the Type III Procollagen N-Terminal Peptide Assay Kit requires careful consideration of product specifications, types, budget, and intended use. This guide aims to provide you with the necessary information to make an informed decision, ensuring that the kit meets your laboratory's needs and supports your diagnostic and research efforts.

 Precautions

Proper handling and storage of the kit are essential to ensure accurate and reliable results. Follow the manufacturer's instructions carefully and adhere to laboratory safety protocols.

1. Storage Conditions: Store the kit at the recommended temperature to maintain the stability and efficacy of the reagents. Avoid exposure to extreme temperatures and direct sunlight.
2. Handling Precautions: Use appropriate personal protective equipment (PPE) when handling the kit. Follow standard laboratory safety protocols to prevent contamination and ensure accurate results.
3. Reagent Preparation: Prepare reagents according to the manufacturer's instructions. Ensure that all components are properly mixed and used within the specified time frame.
4. Calibration: Calibrate the assay according to the provided instructions. Use the calibrators included in the kit to ensure accurate quantification of PⅢNP levels.
5. Disposal: Dispose of used reagents and materials in accordance with local regulations and laboratory waste disposal protocols. Ensure that all biohazardous materials are properly contained and disposed of.

The Type III Procollagen N-Terminal Peptide Assay Kit requires careful handling and storage to ensure accurate and reliable results. Adhering to the manufacturer's instructions and laboratory safety protocols is essential. Proper storage, handling, reagent preparation, calibration, and disposal practices will help maintain the integrity of the kit and support successful diagnostic outcomes.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files