Type III Procollagen N-Terminal Peptide Assay Kit (Magnetic Particle Chemiluminescence Method)
The kit includes high and low value calibrators, PⅢNP antibody reagents A and B, magnetic particle reagent, and quality control samples. Each component is formulated with specific concentrations of PⅢNP antigen or antibodies in buffer solutions, ensuring accurate and reliable detection of PⅢNP levels in human serum.
Product English Name:
Type III Procollagen N-Terminal Peptide Assay Kit (Magnetic Particle Chemiluminescence Method)
Alias:
PⅢNP Assay Kit,Collagen III Peptide Test Kit
Intended Use:
This product is designed for the in vitro quantitative detection of Type III Procollagen N-Terminal Peptide (PⅢNP) in human serum. It is widely used in clinical settings to assess liver fibrosis, monitor disease progression, and evaluate the effectiveness of therapeutic interventions.
Product Introduction

The Type III Procollagen N-Terminal Peptide Assay Kit utilizes magnetic particle chemiluminescence technology to provide precise and sensitive measurements of PⅢNP levels in human serum. This kit is essential for diagnosing and monitoring conditions related to collagen metabolism, particularly liver fibrosis. Its robust design ensures high accuracy and reproducibility, making it a reliable tool for clinical laboratories.

1. The kit features advanced chemiluminescence technology, which enhances sensitivity and specificity in detecting PⅢNP levels. This method minimizes background noise and improves the accuracy of results.
2. The composition includes high and low value calibrators, antibody reagents, and magnetic particles, all formulated to ensure stability and consistency in measurements. Each component is carefully designed to interact precisely with PⅢNP antigens.
3. The primary use of this kit is to quantify PⅢNP in human serum, aiding in the diagnosis and monitoring of liver fibrosis and other collagen-related disorders. It is a critical tool for clinicians to assess disease progression and treatment efficacy.

The Type III Procollagen N-Terminal Peptide Assay Kit, also known as the PⅢNP Assay Kit, is a sophisticated diagnostic tool designed for the precise measurement of PⅢNP levels in human serum. Its advanced technology and carefully formulated components make it an indispensable resource for clinical laboratories focused on collagen metabolism disorders.

Main Features

This assay kit offers high sensitivity and specificity in detecting PⅢNP levels, utilizing magnetic particle chemiluminescence for accurate and reliable results.

1. The kit employs magnetic particle chemiluminescence, which provides high sensitivity and low background noise, ensuring precise detection of PⅢNP.
2. It includes high and low value calibrators, allowing for accurate quantification across a wide range of PⅢNP concentrations.
3. The antibody reagents are specifically designed to bind to PⅢNP with high affinity, ensuring reliable and consistent results.
4. The magnetic particle reagent enhances the separation and detection process, improving the overall efficiency of the assay.
5. Quality control samples are included to verify the accuracy and reproducibility of the assay, ensuring reliable performance in clinical settings.

The Type III Procollagen N-Terminal Peptide Assay Kit stands out for its high sensitivity, specificity, and reliability. Its advanced chemiluminescence technology and well-designed components make it a trusted tool for clinical diagnostics.

Clinical Applications

This kit is primarily used in clinical settings for the diagnosis and monitoring of liver fibrosis and other collagen-related disorders.

1. The kit is widely used in hepatology to assess liver fibrosis, providing critical information for disease diagnosis and staging.
2. It is also employed in monitoring the progression of liver diseases, helping clinicians evaluate the effectiveness of therapeutic interventions.
3. In research settings, the kit is used to study collagen metabolism and its role in various pathological conditions.
4. The assay is valuable in clinical trials for evaluating new treatments targeting collagen-related disorders.
5. It is also used in routine health check-ups to screen for early signs of liver fibrosis in at-risk populations.

The Type III Procollagen N-Terminal Peptide Assay Kit is a versatile tool in clinical diagnostics, particularly for liver fibrosis. Its applications extend from routine health screenings to advanced research, making it an essential resource for healthcare professionals.

Purchasing Guide

This guide provides essential information for purchasing the Type III Procollagen N-Terminal Peptide Assay Kit, including product specifications, types, budget considerations, and usage scenarios.

1. Product parameters: The kit includes high and low value calibrators, antibody reagents, magnetic particles, and quality control samples, all designed for precise PⅢNP detection.
2. Product types: Available in various configurations to meet different laboratory needs, including bulk purchasing options for high-volume users.
3. Budget considerations: The kit is competitively priced, offering high value for its advanced technology and reliable performance.
4. Usage scenarios: Ideal for clinical laboratories, research institutions, and pharmaceutical companies involved in collagen metabolism studies and liver fibrosis diagnostics.

Purchasing the Type III Procollagen N-Terminal Peptide Assay Kit requires careful consideration of product specifications, types, and budget. Its versatility and reliability make it a valuable investment for various clinical and research applications.

 Precautions

Proper handling and storage of the Type III Procollagen N-Terminal Peptide Assay Kit are crucial to ensure accurate results and maintain the integrity of the components.

1. Store the kit at the recommended temperature to preserve the stability of the reagents and ensure reliable performance.
2. Follow the manufacturer's instructions for handling and disposal of reagents to avoid contamination and ensure safety.
3. Use the kit within its expiration date to guarantee the accuracy and reliability of the results.
4. Ensure that all laboratory personnel are trained in the proper use of the kit to minimize errors and ensure consistent results.
5. Regularly calibrate and maintain the equipment used with the kit to ensure optimal performance and accuracy.

The Type III Procollagen N-Terminal Peptide Assay Kit requires careful handling and storage to maintain its performance and accuracy. Adhering to the recommended guidelines ensures reliable results and prolongs the kit's usability.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files