Gamma-Glutamyl Transferase Assay Kit (GCANA Method)
The Gamma-Glutamyl Transferase Assay Kit is composed of two main reagents. Reagent 1 contains Tris buffer (100 mmol/L), glycylglycine (100 mmol/L), and a controlled amount of dodecyl nonaethylene glycol ether. Reagent 2 consists of a phosphate-citrate buffer (100 mmol/L), gamma-glutamyl-3-carboxy-p-nitroaniline (4.0 mmol/L), and an appropriate amount of PIPES (Piperazine-N,N'-bis(2-ethanesulfonic acid)). These components are carefully formulated to ensure accurate and reliable measurement of GGT activity in serum.
Product English Name:
Gamma-Glutamyl Transferase Assay Kit (GCANA Method)
Alias:
GGT Assay Kit,Gamma-GT Test Kit
Intended Use:
This kit is designed for the in vitro quantitative determination of gamma-glutamyl transferase (GGT) activity in human serum. It is widely used in clinical laboratories to assess liver function and diagnose hepatobiliary diseases, as elevated GGT levels are often associated with liver damage, bile duct obstruction, and alcohol consumption.
Product Introduction

The Gamma-Glutamyl Transferase Assay Kit (GCANA Method) is a high-quality diagnostic tool used to measure GGT activity in serum. GGT is an enzyme that plays a crucial role in the metabolism of glutathione and the transport of amino acids. This kit is essential for evaluating liver health and diagnosing conditions such as liver disease, bile duct obstruction, and alcohol-related liver damage. It offers high sensitivity, precision, and ease of use, making it a preferred choice for clinical laboratories.

1. The kit features a two-reagent system that ensures stability and accuracy. Reagent 1 contains Tris buffer and glycylglycine, which provide the optimal pH and substrate for the enzymatic reaction. Reagent 2 includes gamma-glutamyl-3-carboxy-p-nitroaniline, which reacts with GGT to produce a measurable color change.
2. The composition of the kit is designed to minimize interference and maximize specificity. The inclusion of dodecyl nonaethylene glycol ether in Reagent 1 enhances the solubility of the substrate, while PIPES in Reagent 2 stabilizes the reaction environment.
3. This kit is primarily used in clinical settings to assess liver function. Elevated GGT levels are indicative of liver damage, bile duct obstruction, or excessive alcohol consumption. The kit provides reliable results that aid in the diagnosis and monitoring of these conditions.

The Gamma-Glutamyl Transferase Assay Kit, also known as the GGT Assay Kit, is a vital tool in clinical diagnostics. Its carefully formulated reagents ensure accurate measurement of GGT activity, making it indispensable for evaluating liver health. Whether you're diagnosing liver disease or monitoring treatment progress, this kit delivers consistent and reliable results.

Main Features

The Gamma-Glutamyl Transferase Assay Kit offers high sensitivity, precision, and ease of use. Its two-reagent system ensures stable and accurate results, making it ideal for clinical laboratories.

1. High Sensitivity: The kit detects even low levels of GGT activity, ensuring accurate diagnosis of liver conditions.
2. Precision: The carefully balanced reagent composition minimizes variability and ensures reproducible results.
3. Ease of Use: The kit is designed for straightforward operation, reducing the risk of user error.
4. Stability: The reagents are stable under recommended storage conditions, ensuring long shelf life.
5. Specificity: The kit is highly specific for GGT, reducing the likelihood of cross-reactivity with other enzymes.

The Gamma-Glutamyl Transferase Assay Kit stands out for its sensitivity, precision, and user-friendly design. It’s a reliable choice for clinical laboratories, offering consistent results that are crucial for accurate diagnosis and monitoring of liver health.

Clinical Applications

This kit is widely used in clinical settings to assess liver function and diagnose hepatobiliary diseases. It is particularly useful for detecting liver damage, bile duct obstruction, and alcohol-related liver conditions.

1. Liver Function Testing: The kit is routinely used to evaluate liver health by measuring GGT activity in serum.
2. Diagnosis of Hepatobiliary Diseases: Elevated GGT levels are indicative of liver damage or bile duct obstruction, aiding in diagnosis.
3. Alcohol-Related Liver Damage: The kit helps identify excessive alcohol consumption, which is often associated with elevated GGT levels.
4. Monitoring Treatment: It is used to monitor the effectiveness of treatments for liver diseases.
5. Research Applications: The kit is also used in research studies to investigate the role of GGT in various physiological and pathological processes.

The Gamma-Glutamyl Transferase Assay Kit is a versatile tool in clinical diagnostics, essential for assessing liver function and diagnosing hepatobiliary diseases. Its applications extend from routine testing to research, making it a valuable asset in both clinical and laboratory settings.

Purchasing Guide

When purchasing the Gamma-Glutamyl Transferase Assay Kit, consider factors such as product specifications, budget, and intended use to ensure it meets your laboratory's needs.

1. Product Specifications: Review the kit's components, sensitivity, and stability to ensure it aligns with your testing requirements.
2. Product Types: Choose between different kit formats (e.g., single-use vs. bulk) based on your laboratory's workflow and volume of testing.
3. Budget: Consider the cost per test and overall budget to ensure the kit is cost-effective for your laboratory.
4. Usage Scenarios: Evaluate the kit's suitability for your specific applications, such as routine testing or research.

Selecting the right Gamma-Glutamyl Transferase Assay Kit involves careful consideration of product specifications, budget, and intended use. By taking these factors into account, you can ensure the kit meets your laboratory's needs and delivers reliable results.

 Precautions

Proper handling and storage of the Gamma-Glutamyl Transferase Assay Kit are essential to ensure accurate results and maintain reagent stability.

1. Storage Conditions: Store the kit at the recommended temperature to maintain reagent stability.
2. Handling: Follow proper laboratory procedures to avoid contamination or degradation of reagents.
3. Calibration: Regularly calibrate equipment to ensure accurate measurement of GGT activity.
4. Expiration Date: Do not use reagents past their expiration date, as this may affect results.
5. Safety: Wear appropriate protective equipment when handling reagents to avoid exposure.

To get the most out of the Gamma-Glutamyl Transferase Assay Kit, it's crucial to follow proper storage, handling, and safety protocols. These precautions ensure the kit performs as expected and delivers reliable results for your clinical or research needs.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files