The Gamma-Glutamyl Transferase (γ-GT) Assay Kit is a specialized diagnostic tool designed for the accurate measurement of γ-GT enzyme activity in human serum or plasma. Utilizing the IFCC rate method, this kit ensures high precision and reliability in clinical diagnostics. It is widely used in medical laboratories to support the diagnosis and monitoring of liver and biliary system diseases.
1. The kit features a highly sensitive and specific assay method, ensuring accurate detection of γ-GT activity. Its design allows for easy integration into automated biochemical analyzers, making it suitable for high-throughput clinical laboratories.
2. The composition includes two reagents: Reagent 1 contains Tris and glycylglycine, while Reagent 2 includes γ-glutamyl-3-carboxy-p-nitroaniline and sodium azide. These components are optimized to work synergistically, providing consistent and reliable results.
3. The primary use of this kit is in the clinical diagnosis of liver and biliary system diseases. By measuring γ-GT activity, healthcare professionals can assess liver function, detect hepatic disorders, and monitor the progression of liver diseases.
The Gamma-Glutamyl Transferase (γ-GT) Assay Kit, also known as the GGT Assay Kit, is a vital tool in clinical diagnostics. Its precise measurement of γ-GT activity aids in the diagnosis and monitoring of liver and biliary system diseases. The kit's robust design and reliable performance make it an essential component in modern medical laboratories.
The Gamma-Glutamyl Transferase (γ-GT) Assay Kit offers high sensitivity and specificity in measuring γ-GT activity. It is designed for use with automated biochemical analyzers, providing consistent and reliable results in clinical diagnostics.
1. The kit employs the IFCC rate method, ensuring high accuracy and precision in γ-GT activity measurement. This method is widely recognized and standardized in clinical laboratories.
2. It features a two-reagent system, with each reagent containing optimized concentrations of key components. This design ensures stable and reproducible results across different batches.
3. The assay is highly sensitive, capable of detecting low levels of γ-GT activity in serum or plasma. This sensitivity is crucial for early detection of liver diseases.
4. The kit is compatible with a wide range of automated biochemical analyzers, making it versatile and easy to integrate into existing laboratory workflows.
5. It provides a rapid and efficient assay, with results typically available within a short time frame. This efficiency is essential for timely clinical decision-making.
The Gamma-Glutamyl Transferase (γ-GT) Assay Kit stands out for its accuracy, sensitivity, and compatibility with automated systems. Its robust design and reliable performance make it an indispensable tool in clinical diagnostics, particularly for liver and biliary system diseases.
The Gamma-Glutamyl Transferase (γ-GT) Assay Kit is primarily used in clinical settings to aid in the diagnosis and monitoring of liver and biliary system diseases. It provides critical data for assessing liver function and identifying potential hepatic disorders.
1. The kit is used to measure γ-GT activity in serum or plasma, providing valuable information for the diagnosis of liver diseases such as hepatitis, cirrhosis, and liver cancer.
2. It aids in the assessment of biliary system disorders, including cholestasis and biliary obstruction. Elevated γ-GT levels can indicate issues with bile flow and liver function.
3. The assay is also used in the monitoring of patients with chronic liver diseases, helping healthcare professionals track disease progression and response to treatment.
4. In addition to liver and biliary system diseases, the kit can be used to assess the impact of alcohol consumption on liver function, as γ-GT levels are often elevated in individuals with alcohol-related liver damage.
5. The kit is also employed in research settings to study the role of γ-GT in various physiological and pathological processes, contributing to a deeper understanding of liver function and disease mechanisms.
The Gamma-Glutamyl Transferase (γ-GT) Assay Kit is a versatile tool in clinical diagnostics, providing essential data for the diagnosis and monitoring of liver and biliary system diseases. Its applications extend to research, where it contributes to the understanding of liver function and disease mechanisms.
When purchasing the Gamma-Glutamyl Transferase (γ-GT) Assay Kit, it is important to consider factors such as product specifications, compatibility with existing laboratory equipment, and budget constraints. This guide provides essential information to help make an informed decision.
1. Product Specifications: Ensure that the kit meets the required specifications for sensitivity, accuracy, and precision. Check the concentration of reagents and compatibility with your biochemical analyzer.
2. Product Types: There are different types of γ-GT assay kits available, including manual and automated versions. Choose the one that best fits your laboratory's workflow and throughput requirements.
3. Budget Considerations: Evaluate the cost of the kit in relation to your laboratory's budget. Consider the long-term benefits of investing in a high-quality kit that provides reliable and consistent results.
4. Usage Scenarios: Assess the specific needs of your laboratory, such as the volume of tests performed and the types of samples analyzed. Choose a kit that aligns with these requirements to ensure optimal performance.
Purchasing the Gamma-Glutamyl Transferase (γ-GT) Assay Kit requires careful consideration of product specifications, compatibility, and budget. By selecting the right kit for your laboratory's needs, you can ensure accurate and reliable results in clinical diagnostics.
When using the Gamma-Glutamyl Transferase (γ-GT) Assay Kit, it is important to follow proper handling and storage procedures to ensure accurate results and maintain the integrity of the reagents.
1. Storage Conditions: Store the kit at the recommended temperature to maintain the stability of the reagents. Avoid exposure to extreme temperatures or direct sunlight.
2. Handling Precautions: Use appropriate personal protective equipment (PPE) when handling the reagents. Avoid contact with skin and eyes, and do not ingest the reagents.
3. Sample Preparation: Ensure that serum or plasma samples are properly collected and processed to avoid contamination or degradation. Follow standard laboratory protocols for sample handling.
4. Calibration and Quality Control: Regularly calibrate the biochemical analyzer and perform quality control tests to ensure the accuracy and precision of the assay results.
5. Disposal: Dispose of used reagents and samples according to local regulations and laboratory waste disposal protocols. Avoid improper disposal to prevent environmental contamination.
Proper handling, storage, and disposal of the Gamma-Glutamyl Transferase (γ-GT) Assay Kit are essential to ensure accurate results and maintain laboratory safety. By following these precautions, you can optimize the performance of the kit and protect the health and safety of laboratory personnel.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.