Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
β2-Microglobulin (β2-MG) Assay Kit (Immunonephelometry)
The kit consists of R1, R2, optional calibrators, and optional controls. The main components include: 1. Reagent 1 (R1): Tris buffer solution. 2. Reagent 2 (R2): Latex microparticles coated with β2-microglobulin antibodies (rabbit-derived). 3. Calibrators and controls: Tris buffer, sodium chloride, preservatives, and recombinant β2-microglobulin antigen.
Product English Name:
β2-Microglobulin (β2-MG) Assay Kit (Immunonephelometry)
Alias:
β2-MG Test Kit,Nephelometric β2-Microglobulin Kit
Intended Use:
This kit is designed for the quantitative determination of β2-microglobulin in human serum and urine. Clinically, it is primarily used to monitor the function of the proximal renal tubules.
Product Introduction

The β2-Microglobulin (β2-MG) Assay Kit is a sophisticated diagnostic tool used in clinical laboratories to measure the levels of β2-microglobulin in human serum and urine. This protein is a key indicator of renal function, particularly in assessing the health of the proximal renal tubules. The kit employs immunonephelometry, a highly sensitive and specific method, ensuring accurate and reliable results. It is an essential tool for nephrologists and other healthcare professionals in diagnosing and managing kidney-related disorders.

1. The kit features a highly sensitive immunonephelometric method, which allows for precise measurement of β2-microglobulin levels. This method is known for its accuracy and reliability in clinical diagnostics.
2. The composition of the kit includes two main reagents: R1, which is a Tris buffer solution, and R2, which contains latex microparticles coated with β2-microglobulin antibodies. Additionally, optional calibrators and controls are provided to ensure the accuracy of the assay.
3. The primary use of this kit is to quantitatively determine β2-microglobulin levels in human serum and urine. This measurement is crucial for assessing the function of the proximal renal tubules, making it an invaluable tool in nephrology.

The β2-Microglobulin (β2-MG) Assay Kit, also known as the Nephelometric β2-Microglobulin Kit, is a critical diagnostic tool in nephrology. Its ability to accurately measure β2-microglobulin levels in serum and urine makes it indispensable for assessing renal function. The kit's sophisticated design and reliable performance ensure that healthcare professionals can trust the results, aiding in the diagnosis and management of kidney-related conditions.

Main Features

The β2-Microglobulin (β2-MG) Assay Kit offers high sensitivity and specificity in measuring β2-microglobulin levels, making it a reliable tool for clinical diagnostics.

1. The kit utilizes immunonephelometry, a method known for its high sensitivity and specificity, ensuring accurate measurement of β2-microglobulin levels.
2. It includes two main reagents: R1, a Tris buffer solution, and R2, which contains latex microparticles coated with β2-microglobulin antibodies. These components work together to provide precise results.
3. The kit also offers optional calibrators and controls, which are essential for validating the accuracy of the assay and ensuring consistent performance.
4. The assay is designed for use with human serum and urine, making it versatile for various clinical applications, particularly in nephrology.
5. The kit is easy to use, with clear instructions and a straightforward protocol, making it accessible for laboratory technicians and healthcare professionals.

The β2-Microglobulin (β2-MG) Assay Kit stands out for its high sensitivity, specificity, and ease of use. Its comprehensive design, including optional calibrators and controls, ensures reliable and accurate results, making it an essential tool in clinical diagnostics, particularly in the field of nephrology.

Clinical Applications

The β2-Microglobulin (β2-MG) Assay Kit is widely used in clinical settings to monitor renal function, particularly in patients with kidney disorders.

1. The kit is primarily used to monitor the function of the proximal renal tubules, providing critical information for the diagnosis and management of kidney diseases.
2. It is also used in the assessment of patients with conditions such as chronic kidney disease, acute kidney injury, and other renal disorders.
3. The assay is valuable in monitoring the progression of kidney disease and evaluating the effectiveness of treatment regimens.
4. In addition to renal function monitoring, the kit can be used in research settings to study the role of β2-microglobulin in various physiological and pathological processes.
5. The kit's high sensitivity and specificity make it a reliable tool for clinical laboratories, ensuring accurate and consistent results in patient care.

The β2-Microglobulin (β2-MG) Assay Kit is a versatile and reliable tool in clinical nephrology. Its ability to accurately measure β2-microglobulin levels in serum and urine makes it indispensable for monitoring renal function and managing kidney diseases. The kit's consistent performance and ease of use ensure that healthcare professionals can rely on it for accurate diagnostics and effective patient care.

Purchasing Guide

The β2-Microglobulin (β2-MG) Assay Kit is designed for clinical laboratories, offering high sensitivity and specificity in measuring β2-microglobulin levels.

1. When purchasing the kit, consider the product parameters, such as the sensitivity, specificity, and range of detection, to ensure it meets your laboratory's needs.
2. The kit is available in different types, including those with or without calibrators and controls. Choose the type that best fits your laboratory's requirements and budget.
3. Budget considerations are important when purchasing the kit. Ensure that the cost aligns with your laboratory's financial constraints while still meeting your diagnostic needs.
4. Consider the intended use scenarios, such as routine clinical diagnostics or research applications, to select the most appropriate kit for your laboratory.

Purchasing the β2-Microglobulin (β2-MG) Assay Kit requires careful consideration of product parameters, types, budget, and intended use scenarios. By selecting the right kit, laboratories can ensure accurate and reliable results, making it a valuable tool in clinical diagnostics and research.

 Precautions

Proper handling and storage of the β2-Microglobulin (β2-MG) Assay Kit are essential to ensure accurate results and maintain the integrity of the reagents.

1. Always store the kit at the recommended temperature to preserve the stability and effectiveness of the reagents.
2. Handle the reagents with care, avoiding contamination and ensuring proper mixing as per the instructions.
3. Use the kit within its expiration date to ensure the accuracy and reliability of the results.
4. Follow the manufacturer's instructions for calibration and quality control to maintain the performance of the assay.
5. Dispose of used reagents and materials according to laboratory safety protocols to prevent contamination and ensure a safe working environment.

The β2-Microglobulin (β2-MG) Assay Kit requires careful handling and storage to ensure accurate and reliable results. By following the manufacturer's instructions and adhering to laboratory safety protocols, users can maintain the integrity of the reagents and achieve consistent performance in clinical diagnostics.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files