β2-Microglobulin Assay Kit (Nephelometric Method)
The β2-Microglobulin Assay Kit consists of two main reagents: R1, which is a Tris buffer solution, and R2, which contains latex particles coated with rabbit anti-human β2-microglobulin antibodies. Additionally, the kit includes a calibration card with pre-defined calibration curve parameters for accurate quantification.
Product English Name:
β2-Microglobulin Assay Kit (Nephelometric Method)
Alias:
β2-MG Kit,Nephelometric β2-Microglobulin Test
Intended Use:
This kit is designed for the quantitative detection of β2-microglobulin levels in human serum samples. Clinically, it is primarily used to monitor the function of the proximal renal tubules, aiding in the diagnosis and management of kidney-related disorders.
Product Introduction

The β2-Microglobulin Assay Kit is a specialized diagnostic tool used to measure the concentration of β2-microglobulin in serum. This protein is a key biomarker for assessing renal tubular function and is often elevated in conditions such as renal impairment, autoimmune diseases, and certain cancers. The kit employs a nephelometric method, ensuring high sensitivity and precision in detecting low concentrations of β2-microglobulin.

1. The kit features a highly sensitive nephelometric method, which allows for the accurate detection of β2-microglobulin even at low concentrations. This makes it particularly useful in clinical settings where precise measurements are critical.
2. The composition of the kit includes a Tris buffer solution (R1) and latex particles coated with specific antibodies (R2). These components work together to ensure a stable and reliable reaction, minimizing variability in test results.
3. The primary use of this kit is in the clinical monitoring of renal tubular function. By measuring β2-microglobulin levels, healthcare providers can assess kidney health and detect early signs of renal dysfunction.

The β2-Microglobulin Assay Kit, also known as the β2-MG Kit, is a vital tool in clinical diagnostics. Its ability to accurately measure β2-microglobulin levels makes it indispensable for monitoring kidney function. The kit's design, featuring a Tris buffer and antibody-coated latex particles, ensures reliable and consistent results, making it a trusted choice for healthcare professionals.

Main Features

The β2-Microglobulin Assay Kit offers high sensitivity and precision in detecting β2-microglobulin levels, making it an essential tool for clinical diagnostics.

1. The kit utilizes a nephelometric method, which provides high sensitivity and accuracy in detecting low concentrations of β2-microglobulin.
2. It includes a Tris buffer solution (R1) that ensures a stable reaction environment, reducing variability in test results.
3. The latex particles in R2 are coated with specific antibodies, ensuring a highly specific reaction with β2-microglobulin.
4. The calibration card included in the kit allows for easy and accurate quantification of β2-microglobulin levels.
5. The kit is designed for use in clinical laboratories, providing reliable results for monitoring renal tubular function.

The β2-Microglobulin Assay Kit stands out for its precision and reliability. Its nephelometric method, combined with a stable Tris buffer and specific antibody-coated latex particles, ensures accurate detection of β2-microglobulin. This makes it an invaluable tool for clinicians monitoring kidney health.

Clinical Applications

The β2-Microglobulin Assay Kit is widely used in clinical settings to monitor renal tubular function and diagnose kidney-related disorders.

1. The kit is used to measure β2-microglobulin levels in serum, providing critical information about renal tubular function.
2. It is commonly employed in the diagnosis and management of kidney diseases, such as chronic kidney disease and renal tubular acidosis.
3. The kit is also used in the monitoring of patients undergoing treatment for autoimmune diseases, where β2-microglobulin levels may be elevated.
4. In oncology, the kit aids in the assessment of certain cancers, such as multiple myeloma, where β2-microglobulin is a key biomarker.
5. The kit is valuable in research settings, where precise measurement of β2-microglobulin is required for studies on renal function and disease progression.

The β2-Microglobulin Assay Kit is a versatile tool in clinical practice, used for monitoring renal function, diagnosing kidney diseases, and assessing certain cancers. Its ability to provide accurate and reliable results makes it a cornerstone in both clinical and research settings.

Purchasing Guide

When purchasing the β2-Microglobulin Assay Kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your clinical needs.

1. Product specifications: Ensure the kit includes all necessary components, such as R1, R2, and a calibration card, and verify the sensitivity and accuracy of the nephelometric method.
2. Product types: Choose between different kit sizes or configurations based on the volume of tests you plan to perform.
3. Budget: Consider the cost per test and the overall budget for your laboratory, ensuring the kit provides good value for its price.
4. Usage scenarios: Assess whether the kit is suitable for your specific clinical or research needs, such as monitoring renal function or diagnosing kidney diseases.

Purchasing the β2-Microglobulin Assay Kit requires careful consideration of its specifications, types, and cost. By evaluating these factors, you can ensure that the kit meets your clinical requirements and provides reliable results for your diagnostic needs.

 Precautions

Proper handling and storage of the β2-Microglobulin Assay Kit are essential to ensure accurate and reliable results.

1. Store the kit at the recommended temperature to maintain the stability of the reagents and calibration card.
2. Follow the manufacturer's instructions for handling and preparing the reagents to avoid contamination or degradation.
3. Ensure that the nephelometer used with the kit is properly calibrated and maintained to achieve accurate readings.
4. Use appropriate protective equipment, such as gloves and lab coats, when handling the reagents to prevent exposure.
5. Dispose of used reagents and materials according to local regulations and laboratory safety protocols.

To ensure the best results with the β2-Microglobulin Assay Kit, it's crucial to follow proper storage, handling, and disposal procedures. By adhering to these precautions, you can maintain the integrity of the reagents and achieve reliable diagnostic outcomes.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files