Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
25-Hydroxyvitamin D Assay Kit (Fluorescence Immunochromatography)
The kit consists of a detection card (20 tests), buffer solution, and calibration card. The detection card includes a fluorescence pad coated with fluorescent-labeled mouse anti-25-Hydroxyvitamin D monoclonal antibody, a nitrocellulose membrane coated with 25-Hydroxyvitamin D-BSA (test zone) and rabbit anti-mouse polyclonal antibody (control zone), absorbent paper, sample pad, backing, and plastic shell. The buffer solution is a phosphate buffer used as a dissociating agent.
Product English Name:
25-Hydroxyvitamin D Assay Kit (Fluorescence Immunochromatography)
Alias:
Vitamin D Test Kit,25(OH)D Assay Kit
Intended Use:
This kit is designed for the quantitative in vitro detection of 25-Hydroxyvitamin D concentration in whole blood, serum, or plasma samples. Clinically, it is primarily used for the auxiliary diagnosis of diseases related to vitamin D deficiency.
Product Introduction

The 25-Hydroxyvitamin D Assay Kit utilizes fluorescence immunochromatography to provide accurate and reliable measurements of vitamin D levels in biological samples. It is an essential tool for healthcare professionals to assess vitamin D status, which is crucial for bone health, immune function, and overall well-being.

1. The kit features a highly sensitive fluorescence detection system, ensuring precise measurement of 25-Hydroxyvitamin D levels. Its user-friendly design allows for quick and easy operation, making it suitable for both clinical and research settings.
2. The detection card is composed of multiple layers, including a fluorescence pad, nitrocellulose membrane, absorbent paper, and sample pad, all housed within a durable plastic shell. This structure ensures efficient sample flow and accurate results.
3. The kit is specifically designed for the quantitative detection of 25-Hydroxyvitamin D in blood samples. It is widely used in clinical diagnostics to aid in the assessment of vitamin D deficiency and related health conditions.

The 25-Hydroxyvitamin D Assay Kit, also known as the Vitamin D Test Kit, is a reliable and efficient tool for measuring vitamin D levels. Its advanced fluorescence immunochromatography technology ensures accurate results, making it an indispensable resource for healthcare providers.

Main Features

This kit offers high sensitivity and specificity in detecting 25-Hydroxyvitamin D levels, with a user-friendly design suitable for various clinical applications.

1. The fluorescence detection system provides high sensitivity, ensuring accurate measurement of low concentrations of 25-Hydroxyvitamin D.
2. The kit includes a calibration card for precise standardization, enhancing the reliability of test results.
3. The buffer solution acts as a dissociating agent, facilitating the release of 25-Hydroxyvitamin D from binding proteins for accurate detection.
4. The detection card's multi-layer structure ensures efficient sample flow and minimizes interference, leading to consistent and reliable results.
5. The kit is designed for ease of use, with clear instructions and minimal preparation time, making it suitable for high-throughput testing.

The 25-Hydroxyvitamin D Assay Kit stands out for its high sensitivity, ease of use, and reliable performance. It is an essential tool for healthcare professionals to accurately assess vitamin D levels and diagnose related conditions.

Clinical Applications

This kit is widely used in clinical settings to diagnose and monitor vitamin D deficiency, which is associated with various health conditions such as osteoporosis, rickets, and immune disorders.

1. The kit is used in routine health check-ups to assess vitamin D status, particularly in populations at risk of deficiency, such as the elderly and those with limited sun exposure.
2. It aids in the diagnosis of osteoporosis by providing accurate measurements of 25-Hydroxyvitamin D levels, which are crucial for bone health.
3. The kit is employed in pediatric care to diagnose rickets, a condition caused by severe vitamin D deficiency in children.
4. It is used in research studies to investigate the role of vitamin D in immune function and its potential impact on autoimmune diseases.
5. The kit is also utilized in monitoring vitamin D levels in patients undergoing treatment for vitamin D deficiency, ensuring optimal therapeutic outcomes.

The 25-Hydroxyvitamin D Assay Kit is a versatile tool in clinical practice, aiding in the diagnosis and management of vitamin D deficiency and related conditions. Its accuracy and reliability make it a trusted resource for healthcare providers.

Purchasing Guide

When purchasing the 25-Hydroxyvitamin D Assay Kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your clinical or research needs.

1. Evaluate the product specifications, including sensitivity, detection range, and shelf life, to ensure it aligns with your testing requirements.
2. Choose the appropriate kit type based on your testing volume and application, whether for routine clinical use or high-throughput research.
3. Consider your budget and compare prices from different suppliers to find a cost-effective solution without compromising quality.
4. Assess the intended use and ensure the kit is suitable for your specific testing environment, whether in a hospital, clinic, or research laboratory.

Selecting the right 25-Hydroxyvitamin D Assay Kit involves careful consideration of product specifications, type, budget, and intended use. By doing so, you can ensure that the kit meets your needs and delivers reliable results.

 Precautions

Proper handling and storage of the 25-Hydroxyvitamin D Assay Kit are essential to ensure accurate results and maintain product integrity.

1. Store the kit at the recommended temperature to preserve the stability of the reagents and ensure reliable performance.
2. Follow the instructions carefully when preparing and using the kit to avoid contamination and ensure accurate results.
3. Use the kit within its expiration date to guarantee the effectiveness of the reagents and the accuracy of the test results.
4. Handle the detection card with care to avoid damage to the sensitive components, which could affect the test outcome.
5. Dispose of used materials according to local regulations to ensure safety and environmental compliance.

To achieve the best results with the 25-Hydroxyvitamin D Assay Kit, it is crucial to follow proper handling, storage, and disposal procedures. By adhering to these precautions, you can ensure the kit's reliability and maintain a safe testing environment.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files