25-Hydroxy Vitamin D Assay Kit (Fluorescence Immunochromatography)
The kit consists of three main components: (1) Test cards, which include a plastic card and a test strip. The test strip is composed of a nitrocellulose membrane (coated with BSA protein conjugated to 25-hydroxy vitamin D in the test zone and rabbit anti-chicken IgY in the control zone), a fluorescence pad (sprayed with fluorescently labeled 25-hydroxy vitamin D monoclonal antibody and chicken IgY), a sample pad, absorbent paper, and a PVC board. (2) Sample diluent (SZY-1100/AFS2000A), provided in single-use quantities corresponding to the packaging specifications. Each tube contains 150 μL of a phosphate buffer solution (pH 6.5-8.0). (3) ID card, one per box, containing the standard curve data for the batch.
Product English Name:
25-Hydroxy Vitamin D Assay Kit (Fluorescence Immunochromatography)
Alias:
25-OH-VD Test Kit,Vitamin D Quantitative Assay Kit
Intended Use:
This product is used for the quantitative determination of 25-hydroxy vitamin D (25-OH-VD) levels in human serum, plasma, and whole blood in vitro.
Product Introduction

The 25-Hydroxy Vitamin D Assay Kit is a cutting-edge diagnostic tool designed for the precise measurement of 25-hydroxy vitamin D levels in human blood samples. Utilizing fluorescence immunochromatography, this kit offers high sensitivity and specificity, making it an essential tool for clinical laboratories and research institutions. The kit is composed of test cards, sample diluent, and an ID card, ensuring accurate and reliable results.

1. The kit features a unique fluorescence immunochromatography method, which provides high sensitivity and specificity in detecting 25-hydroxy vitamin D levels. This method ensures accurate results even at low concentrations.
2. The test card is constructed with a nitrocellulose membrane coated with BSA protein conjugated to 25-hydroxy vitamin D and rabbit anti-chicken IgY. The fluorescence pad is sprayed with fluorescently labeled antibodies, enhancing the detection capability.
3. The kit is used for the quantitative determination of 25-hydroxy vitamin D in human serum, plasma, and whole blood. It is widely applied in clinical diagnostics to assess vitamin D status, which is crucial for bone health and immune function.

The 25-Hydroxy Vitamin D Assay Kit, also known as the Vitamin D Quantitative Assay Kit, is a sophisticated diagnostic tool that leverages fluorescence immunochromatography for accurate vitamin D level measurement. Its robust design and high sensitivity make it indispensable in clinical settings.

Main Features

The 25-Hydroxy Vitamin D Assay Kit offers high sensitivity, specificity, and reliability in measuring vitamin D levels. It is designed for ease of use in clinical laboratories.

1. High Sensitivity: The fluorescence immunochromatography method ensures accurate detection of low concentrations of 25-hydroxy vitamin D.
2. Specificity: The use of specific antibodies and BSA protein conjugation minimizes cross-reactivity, ensuring precise results.
3. Reliability: The kit includes an ID card with standard curve data, ensuring consistent and reliable measurements across different batches.
4. Ease of Use: The kit is designed for straightforward operation, making it suitable for routine clinical use.
5. Comprehensive Components: The kit includes all necessary components, such as test cards, sample diluent, and an ID card, ensuring a complete diagnostic solution.

The 25-Hydroxy Vitamin D Assay Kit stands out for its high sensitivity, specificity, and reliability. Its user-friendly design and comprehensive components make it a preferred choice for clinical laboratories.

Clinical Applications

The 25-Hydroxy Vitamin D Assay Kit is widely used in clinical settings to assess vitamin D status, which is crucial for bone health, immune function, and overall well-being.

1. Bone Health Assessment: The kit is used to measure vitamin D levels, which are essential for calcium absorption and bone health.
2. Immune Function: Vitamin D plays a critical role in immune system regulation, and the kit helps in assessing its levels.
3. Clinical Diagnostics: The kit is used in clinical laboratories to diagnose vitamin D deficiency or excess.
4. Research Applications: The kit is also used in research studies to investigate the role of vitamin D in various health conditions.
5. Public Health: The kit is employed in public health programs to monitor and improve population vitamin D status.

The 25-Hydroxy Vitamin D Assay Kit is a versatile tool in clinical diagnostics, research, and public health. Its ability to accurately measure vitamin D levels makes it invaluable for assessing bone health, immune function, and overall well-being.

Purchasing Guide

When purchasing the 25-Hydroxy Vitamin D Assay Kit, consider product specifications, types, budget, and intended use to ensure the best fit for your needs.

1. Product Specifications: Evaluate the kit's sensitivity, specificity, and reliability to ensure it meets your diagnostic requirements.
2. Product Types: Choose between different kit formats based on your laboratory's workflow and sample volume.
3. Budget: Consider the cost per test and overall budget to ensure the kit is economically viable for your laboratory.
4. Intended Use: Ensure the kit is suitable for your specific clinical or research applications, such as bone health assessment or immune function studies.

Purchasing the 25-Hydroxy Vitamin D Assay Kit requires careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can select the best kit for your diagnostic needs.

 Precautions

Proper handling and storage of the 25-Hydroxy Vitamin D Assay Kit are essential to ensure accurate and reliable results.

1. Storage Conditions: Store the kit at the recommended temperature to maintain the stability of the components.
2. Handling: Follow the manufacturer's instructions for handling the test cards and sample diluent to avoid contamination.
3. Expiration Date: Use the kit before the expiration date to ensure the reliability of the results.
4. Sample Preparation: Ensure proper sample collection and preparation to avoid errors in the assay.
5. Quality Control: Regularly perform quality control checks to ensure the kit is functioning correctly.

To achieve accurate and reliable results with the 25-Hydroxy Vitamin D Assay Kit, it is crucial to follow proper storage, handling, and quality control procedures. Adhering to these precautions will ensure the kit's optimal performance.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files