Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
β2-Microglobulin Assay Kit (Immunoturbidimetric Method)
The β2-Microglobulin Assay Kit consists of two main reagents: Reagent 1 and Reagent 2, both containing 0.1 mol/L buffer solutions. Reagent 2 additionally includes latex particles coated with β2-MG antibodies at a concentration of 0.12%. The kit also offers optional calibrators and controls for both serum and urine, with varying concentrations of β2-microglobulin to ensure accurate measurement across different ranges.
Product English Name:
β2-Microglobulin Assay Kit (Immunoturbidimetric Method)
Alias:
β2-MG Assay Kit,Immunoturbidimetric β2-Microglobulin Kit
Intended Use:
This kit is designed for the quantitative determination of β2-microglobulin concentrations in human serum and urine. It is widely used in clinical laboratories to assess kidney function, monitor renal diseases, and evaluate the progression of certain cancers and autoimmune disorders.
Product Introduction

The β2-Microglobulin Assay Kit is a reliable and efficient tool for measuring β2-microglobulin levels in biological samples. Utilizing the immunoturbidimetric method, this kit provides precise and reproducible results, making it an essential component in clinical diagnostics. Its comprehensive range of calibrators and controls ensures accuracy across various sample types and concentrations.

1. The kit features a robust immunoturbidimetric method, which ensures high sensitivity and specificity in detecting β2-microglobulin. This method is known for its reliability and ease of use in clinical settings.
2. The composition includes two primary reagents: Reagent 1, a buffer solution, and Reagent 2, which contains latex particles coated with β2-MG antibodies. Optional calibrators and controls are available for both serum and urine samples, providing flexibility in assay setup.
3. The primary use of this kit is to measure β2-microglobulin levels in human serum and urine, aiding in the diagnosis and monitoring of renal diseases, certain cancers, and autoimmune conditions. Its accuracy and reliability make it a valuable tool in clinical laboratories.

The β2-Microglobulin Assay Kit, also known as the Immunoturbidimetric β2-Microglobulin Kit, is a highly effective diagnostic tool. Its robust design and comprehensive components ensure accurate and reliable results, making it indispensable in clinical settings for assessing kidney function and monitoring disease progression.

Main Features

The β2-Microglobulin Assay Kit offers high sensitivity and specificity in detecting β2-microglobulin levels. Its immunoturbidimetric method ensures reliable and reproducible results, making it a preferred choice in clinical diagnostics.

1. High Sensitivity: The kit is designed to detect low concentrations of β2-microglobulin, ensuring accurate results even in samples with minimal analyte levels.
2. Specificity: The use of latex particles coated with β2-MG antibodies ensures that the assay specifically targets β2-microglobulin, reducing the risk of cross-reactivity with other proteins.
3. Reproducibility: The kit provides consistent results across multiple runs, ensuring reliability in clinical diagnostics.
4. Comprehensive Calibrators: The inclusion of multiple calibrators for both serum and urine samples allows for accurate measurement across a wide range of concentrations.
5. Ease of Use: The kit is designed for straightforward operation, making it accessible to laboratory personnel with varying levels of experience.

The β2-Microglobulin Assay Kit stands out for its high sensitivity, specificity, and reproducibility. Its comprehensive calibrators and user-friendly design make it an essential tool in clinical laboratories for accurate and reliable β2-microglobulin measurement.

Clinical Applications

The β2-Microglobulin Assay Kit is widely used in clinical settings to assess kidney function, monitor renal diseases, and evaluate the progression of certain cancers and autoimmune disorders.

1. Renal Function Assessment: The kit is commonly used to measure β2-microglobulin levels in serum and urine, providing critical information about kidney function and the early detection of renal diseases.
2. Cancer Monitoring: Elevated levels of β2-microglobulin are often associated with certain cancers, such as multiple myeloma. The kit aids in monitoring disease progression and treatment efficacy.
3. Autoimmune Disorders: The kit is also used in the evaluation of autoimmune disorders, where β2-microglobulin levels can indicate disease activity and response to therapy.
4. Transplant Monitoring: In patients who have undergone kidney transplants, the kit helps monitor graft function and detect early signs of rejection.
5. Research Applications: Beyond clinical diagnostics, the kit is used in research settings to study the role of β2-microglobulin in various diseases and conditions.

The β2-Microglobulin Assay Kit is a versatile tool in clinical diagnostics, used for assessing kidney function, monitoring cancer progression, and evaluating autoimmune disorders. Its applications extend to transplant monitoring and research, making it a valuable asset in both clinical and research settings.

Purchasing Guide

When purchasing the β2-Microglobulin Assay Kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your laboratory's needs.

1. Product Specifications: Review the kit's components, including reagents, calibrators, and controls, to ensure they align with your laboratory's requirements.
2. Product Types: Choose between different kit configurations, such as those with or without calibrators, based on your laboratory's specific needs.
3. Budget: Consider the cost of the kit, including any additional expenses for calibrators or controls, to ensure it fits within your laboratory's budget.
4. Intended Use: Evaluate the kit's intended applications, such as clinical diagnostics or research, to ensure it meets your laboratory's objectives.

Purchasing the β2-Microglobulin Assay Kit requires careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can ensure the kit meets your laboratory's needs and provides reliable results.

 Precautions

Proper handling and storage of the β2-Microglobulin Assay Kit are essential to ensure accurate results and maintain the integrity of the components.

1. Storage Conditions: Store the kit at the recommended temperature to prevent degradation of reagents and ensure consistent performance.
2. Handling: Follow proper handling procedures to avoid contamination and ensure accurate results. Use clean pipettes and avoid cross-contamination between samples.
3. Expiration Date: Check the expiration date of the kit and its components before use. Do not use expired reagents or controls.
4. Calibration: Regularly calibrate the assay using the provided calibrators to ensure accurate and reliable results.
5. Disposal: Dispose of used reagents and samples according to local regulations to ensure safety and environmental compliance.

To ensure accurate and reliable results, it is crucial to follow proper storage, handling, and disposal procedures for the β2-Microglobulin Assay Kit. Regular calibration and adherence to expiration dates are also essential to maintain the kit's performance.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files