The 25-Hydroxy Vitamin D Detection Kit is a state-of-the-art diagnostic tool designed for accurate measurement of 25-OH-VD levels in human biological samples. Utilizing chemiluminescent immunoassay technology, it offers high sensitivity and specificity, making it an essential tool for clinical laboratories. The kit includes all necessary reagents, calibrators, and controls, ensuring reliable and reproducible results.
1. The kit features advanced chemiluminescent immunoassay technology, which provides high sensitivity and specificity for detecting 25-OH-VD levels. This technology ensures accurate results even at low concentrations, making it ideal for clinical diagnostics.
2. The kit is composed of four main reagents (R1, R2, R3, R4), each containing specific components such as streptavidin-coated magnetic particles, Tris buffer, MES buffer, and monoclonal antibodies labeled with acridinium ester. These components work together to ensure precise and reliable detection of 25-OH-VD.
3. The kit is used for the quantitative detection of 25-hydroxy vitamin D (25-OH-VD) in human serum, plasma, and whole blood. It is primarily used in clinical settings to aid in the diagnosis of vitamin D deficiency-related conditions, such as osteoporosis, rickets, and other metabolic bone disorders.
The 25-Hydroxy Vitamin D Detection Kit, also known as the 25-OH-VD Test Kit, is a reliable and efficient tool for measuring vitamin D levels in human samples. Its advanced technology and comprehensive components make it a valuable asset in clinical diagnostics, particularly for identifying vitamin D deficiency-related conditions.
The 25-Hydroxy Vitamin D Detection Kit offers high sensitivity, specificity, and reliability in detecting 25-OH-VD levels. Its advanced chemiluminescent immunoassay technology ensures accurate results, making it a preferred choice for clinical laboratories.
1. High Sensitivity: The kit can detect low concentrations of 25-OH-VD with high precision, ensuring accurate results even in cases of mild vitamin D deficiency.
2. Specificity: The monoclonal antibodies used in the kit are highly specific to 25-OH-VD, minimizing cross-reactivity with other substances and ensuring reliable results.
3. Comprehensive Components: The kit includes all necessary reagents, calibrators, and controls, providing a complete solution for 25-OH-VD detection.
4. User-Friendly: The kit is designed for ease of use, with clear instructions and a straightforward protocol, making it accessible to both experienced and novice users.
5. Reliable Performance: The kit has been rigorously tested and validated to ensure consistent and reproducible results, making it a trusted tool in clinical diagnostics.
The 25-Hydroxy Vitamin D Detection Kit stands out for its high sensitivity, specificity, and user-friendly design. Its comprehensive components and reliable performance make it an indispensable tool for clinical laboratories, ensuring accurate and consistent results in vitamin D diagnostics.
The 25-Hydroxy Vitamin D Detection Kit is widely used in clinical settings to diagnose and monitor vitamin D deficiency-related conditions. Its accurate and reliable results make it a valuable tool for healthcare professionals.
1. Diagnosis of Vitamin D Deficiency: The kit is used to measure 25-OH-VD levels in patients suspected of having vitamin D deficiency, aiding in the diagnosis of conditions such as osteoporosis and rickets.
2. Monitoring Vitamin D Therapy: The kit is used to monitor the effectiveness of vitamin D supplementation in patients undergoing treatment for vitamin D deficiency.
3. Research Applications: The kit is also used in research studies to investigate the role of vitamin D in various health conditions, including metabolic bone disorders and immune system function.
4. Public Health Screening: The kit is used in large-scale public health screening programs to identify populations at risk of vitamin D deficiency and to implement preventive measures.
5. Clinical Trials: The kit is used in clinical trials to evaluate the efficacy and safety of new vitamin D-related therapies and interventions.
The 25-Hydroxy Vitamin D Detection Kit is a versatile tool with a wide range of clinical applications. From diagnosing vitamin D deficiency to monitoring therapy and supporting research, this kit plays a crucial role in improving patient outcomes and advancing medical knowledge.
When purchasing the 25-Hydroxy Vitamin D Detection Kit, it is important to consider factors such as product specifications, types, budget, and intended use to ensure the best fit for your laboratory's needs.
1. Product Specifications: Evaluate the kit's sensitivity, specificity, and detection range to ensure it meets your laboratory's requirements for accurate and reliable results.
2. Product Types: Consider the different types of kits available, such as those with or without calibrators and controls, and choose the one that best suits your laboratory's workflow and testing volume.
3. Budget: Determine your budget for the kit, taking into account the cost of reagents, calibrators, controls, and any additional accessories or consumables that may be required.
4. Intended Use: Consider the specific applications for which the kit will be used, such as clinical diagnostics, research, or public health screening, and choose a kit that is optimized for those purposes.
Purchasing the 25-Hydroxy Vitamin D Detection Kit requires careful consideration of product specifications, types, budget, and intended use. By taking these factors into account, you can ensure that you select the best kit for your laboratory's needs, ultimately leading to more accurate and reliable results.
When using the 25-Hydroxy Vitamin D Detection Kit, it is important to follow all instructions and precautions to ensure accurate and reliable results and to maintain the safety of laboratory personnel.
1. Proper Storage: Store the kit components at the recommended temperature to maintain their stability and effectiveness. Avoid exposure to extreme temperatures or direct sunlight.
2. Handling Reagents: Handle all reagents with care, wearing appropriate personal protective equipment (PPE) such as gloves and lab coats. Avoid contact with skin or eyes, and dispose of any spills or waste according to local regulations.
3. Calibration and Controls: Always use the provided calibrators and controls to ensure the accuracy and reliability of your results. Do not mix components from different kit lots, as this may affect performance.
4. Sample Preparation: Follow the recommended procedures for sample collection, preparation, and storage to avoid contamination or degradation of the samples, which could lead to inaccurate results.
5. Instrument Maintenance: Regularly maintain and calibrate the immunoassay analyzer used with the kit to ensure optimal performance and accurate results.
Using the 25-Hydroxy Vitamin D Detection Kit requires careful attention to storage, handling, calibration, sample preparation, and instrument maintenance. By following these precautions, you can ensure the accuracy and reliability of your results while maintaining a safe laboratory environment.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.