β2-Microglobulin Assay Kit (Immunoturbidimetric Method)
The β2-Microglobulin Assay Kit consists of two main reagents and a calibrator. Reagent 1 contains a phosphate buffer (200mmol/L) and polyethylene glycol 6000 (1%-3%). Reagent 2 includes a phosphate buffer (200mmol/L), β2-microglobulin antibody-sensitized latex (25%-35%), and a stabilizer (0.1%). The calibrator is composed of β2-microglobulin, phosphate buffer, and bovine serum albumin. It is important to note that components from different batches are not interchangeable.
Product English Name:
β2-Microglobulin Assay Kit (Immunoturbidimetric Method)
Alias:
β2-MG Test Kit,Renal Function Monitoring Kit
Intended Use:
This kit is designed for the quantitative in vitro determination of β2-microglobulin (β2-MG) in human serum samples. Clinically, it is primarily used to monitor the function of the proximal renal tubules, aiding in the diagnosis and management of renal disorders.
Product Introduction

The β2-Microglobulin Assay Kit is a sophisticated diagnostic tool used to measure the levels of β2-microglobulin in human serum. This protein is a key indicator of renal function, particularly in the proximal tubules. The kit employs an immunoturbidimetric method, ensuring high accuracy and reliability. It is widely used in clinical laboratories for its precision and ease of use.

1. The kit features a highly sensitive immunoturbidimetric method, which allows for the precise measurement of β2-microglobulin levels. This method is known for its accuracy and reproducibility, making it a preferred choice in clinical settings.
2. The composition of the kit includes two reagents and a calibrator. Reagent 1 contains a phosphate buffer and polyethylene glycol, while Reagent 2 includes a phosphate buffer, β2-microglobulin antibody-sensitized latex, and a stabilizer. The calibrator is essential for ensuring the accuracy of the measurements.
3. The primary use of this kit is to monitor renal function, particularly the proximal tubules. It is crucial in diagnosing and managing various renal disorders, providing clinicians with valuable information for patient care.

The β2-Microglobulin Assay Kit, also known as the β2-MG Test Kit, is an essential tool in clinical diagnostics. Its precise measurement capabilities and reliable composition make it indispensable for monitoring renal function. The kit's design ensures ease of use and accuracy, making it a trusted choice for healthcare professionals.

Main Features

The β2-Microglobulin Assay Kit offers high sensitivity and accuracy in measuring β2-microglobulin levels, crucial for assessing renal function.

1. The kit utilizes an immunoturbidimetric method, known for its high sensitivity and specificity in detecting β2-microglobulin.
2. It includes a comprehensive set of reagents and a calibrator, ensuring accurate and reproducible results.
3. The kit is designed for ease of use, with clear instructions and minimal preparation time required.
4. It is compatible with a wide range of automated analyzers, making it versatile for various laboratory settings.
5. The kit provides reliable results, essential for the accurate diagnosis and management of renal disorders.

The β2-Microglobulin Assay Kit stands out for its precision, ease of use, and compatibility with automated systems. Its comprehensive design ensures reliable results, making it a valuable tool in clinical diagnostics.

Clinical Applications

The β2-Microglobulin Assay Kit is widely used in clinical settings to monitor renal function and diagnose renal disorders.

1. The kit is essential for monitoring the function of the proximal renal tubules, providing critical information for the diagnosis of renal diseases.
2. It is used in the management of patients with chronic kidney disease, helping clinicians to assess the progression of the disease.
3. The kit is also employed in the evaluation of renal function in patients undergoing chemotherapy, as β2-microglobulin levels can indicate renal toxicity.
4. It is used in research settings to study the role of β2-microglobulin in various renal pathologies.
5. The kit is a valuable tool in the early detection of renal dysfunction, allowing for timely intervention and improved patient outcomes.

The β2-Microglobulin Assay Kit is a versatile tool in clinical practice, essential for monitoring renal function and diagnosing renal disorders. Its applications extend to patient management and research, making it a critical component in the field of nephrology.

Purchasing Guide

The procurement guide for the β2-Microglobulin Assay Kit provides essential information on product specifications, types, budget considerations, and usage scenarios.

1. Product parameters include the composition of reagents, calibrator details, and the method of measurement. It is crucial to ensure compatibility with existing laboratory equipment.
2. The kit is available in various types, including different batch sizes and formats. Selecting the appropriate type depends on the laboratory's volume and specific needs.
3. Budget considerations should include the cost per test, the shelf life of the kit, and the potential for bulk purchasing discounts.
4. Usage scenarios involve assessing the laboratory's workflow, the frequency of tests, and the need for automation. It is important to choose a kit that integrates seamlessly with the laboratory's operations.

Procuring the β2-Microglobulin Assay Kit requires careful consideration of product specifications, types, and budget. Understanding the laboratory's needs and workflow is essential for making an informed decision.

 Precautions

Proper handling and storage of the β2-Microglobulin Assay Kit are essential to ensure accurate results and maintain the integrity of the reagents.

1. Always store the kit at the recommended temperature to prevent degradation of the reagents. Exposure to extreme temperatures can affect the performance of the kit.
2. Ensure that all components are used within their expiration dates. Using expired reagents can lead to inaccurate results.
3. Follow the instructions for use carefully, including the preparation of reagents and the calibration process. Deviations from the protocol can compromise the accuracy of the test.
4. Handle all components with care, avoiding contamination. Use sterile techniques and appropriate personal protective equipment (PPE) to maintain the integrity of the samples.
5. Regularly calibrate the equipment used with the kit to ensure consistent and accurate measurements. Proper maintenance of laboratory instruments is crucial for reliable results.

The β2-Microglobulin Assay Kit requires careful handling and storage to ensure accurate and reliable results. Adhering to the recommended protocols and maintaining proper laboratory practices are essential for optimal performance.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files