Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
β2-Microglobulin Calibrator
The β2-Microglobulin Calibrator is composed of disodium hydrogen phosphate dodecahydrate, sodium dihydrogen phosphate dihydrate, glycerol, disodium ethylenediaminetetraacetate, sodium azide, β2-microglobulin antigen, sucrose, bovine serum albumin, and sodium chloride. This precise formulation ensures stability and accuracy in calibration processes.
Product English Name:
β2-Microglobulin Calibrator
Alias:
β2-M Calibrator,Microglobulin Standard
Intended Use:
This product is designed to be used in conjunction with the β2-Microglobulin Assay Kit (Latex Immunoturbidimetric Method) produced by Weihai Weigao Biotechnology Co., Ltd. It is specifically used for the calibration of β2-microglobulin measurements, ensuring reliable and consistent results in diagnostic testing.
Product Introduction

The β2-Microglobulin Calibrator is a critical component in the accurate measurement of β2-microglobulin levels, which are essential for diagnosing and monitoring various medical conditions. This calibrator is meticulously formulated to provide precise and stable calibration for diagnostic assays, ensuring that healthcare professionals can rely on the results for patient care.

1. The β2-Microglobulin Calibrator is characterized by its high stability and precision, making it an indispensable tool in clinical diagnostics. Its formulation is designed to mimic human serum, providing accurate calibration for β2-microglobulin assays.
2. The composition of the calibrator includes a balanced mixture of salts, proteins, and stabilizers, such as disodium hydrogen phosphate, glycerol, and bovine serum albumin. These components work together to maintain the integrity and functionality of the β2-microglobulin antigen during storage and use.
3. The primary use of this calibrator is in conjunction with specific assay kits to ensure the accuracy of β2-microglobulin measurements. It is particularly useful in diagnosing kidney disorders, monitoring transplant patients, and assessing immune system function.

The β2-Microglobulin Calibrator, also known as the β2-M Calibrator or Microglobulin Standard, is a vital tool in the field of clinical diagnostics. Its precise formulation and reliable performance make it an essential component for ensuring accurate β2-microglobulin measurements, which are crucial for patient care and treatment decisions.

Main Features

The β2-Microglobulin Calibrator offers high precision and stability, ensuring accurate calibration for β2-microglobulin assays. Its formulation is designed to provide consistent results, making it a reliable tool for clinical diagnostics.

1. High Precision: The calibrator is formulated to provide exact measurements, ensuring that β2-microglobulin levels are accurately determined.
2. Stability: The inclusion of stabilizers like glycerol and bovine serum albumin ensures that the calibrator remains effective over time, even under varying storage conditions.
3. Compatibility: This calibrator is specifically designed to work with the β2-Microglobulin Assay Kit (Latex Immunoturbidimetric Method), ensuring seamless integration into existing diagnostic workflows.
4. Diagnostic Accuracy: By providing precise calibration, the calibrator helps in the accurate diagnosis of conditions such as kidney disorders and immune system dysfunctions.
5. Ease of Use: The calibrator is easy to handle and integrate into laboratory procedures, reducing the potential for errors and improving overall efficiency.

The β2-Microglobulin Calibrator stands out for its precision, stability, and compatibility with specific diagnostic kits. These features make it an invaluable tool in clinical settings, ensuring that healthcare professionals can rely on accurate β2-microglobulin measurements for effective patient care.

Clinical Applications

The β2-Microglobulin Calibrator is widely used in clinical settings for the accurate measurement of β2-microglobulin levels, which are crucial for diagnosing and monitoring various medical conditions.

1. Kidney Disorders: The calibrator is essential in diagnosing and monitoring kidney diseases, where β2-microglobulin levels are a key indicator of renal function.
2. Transplant Monitoring: It is used to monitor transplant patients, helping to detect early signs of organ rejection by tracking changes in β2-microglobulin levels.
3. Immune System Assessment: The calibrator aids in assessing immune system function, particularly in patients with autoimmune diseases or those undergoing immunosuppressive therapy.
4. Cancer Diagnosis: Elevated β2-microglobulin levels can indicate certain types of cancer, making the calibrator a valuable tool in oncology diagnostics.
5. Research Applications: Beyond clinical diagnostics, the calibrator is also used in research settings to study the role of β2-microglobulin in various diseases and conditions.

The β2-Microglobulin Calibrator plays a crucial role in clinical diagnostics, particularly in the fields of nephrology, transplantation, immunology, and oncology. Its ability to provide accurate and reliable measurements makes it an essential tool for healthcare professionals and researchers alike.

Purchasing Guide

When purchasing the β2-Microglobulin Calibrator, it is important to consider product specifications, compatibility with existing diagnostic kits, and the specific needs of your clinical or research setting.

1. Product Parameters: Ensure that the calibrator meets the required specifications for your diagnostic assays, including concentration, stability, and compatibility with your assay kit.
2. Product Type: Choose the appropriate type of calibrator based on your specific diagnostic needs, whether for routine clinical use or specialized research applications.
3. Budget Considerations: Evaluate the cost-effectiveness of the calibrator, considering both the initial purchase price and the long-term benefits of accurate and reliable diagnostics.
4. Usage Scenarios: Consider the specific clinical or research scenarios in which the calibrator will be used, ensuring that it meets the necessary performance criteria for those applications.

Purchasing the β2-Microglobulin Calibrator requires careful consideration of product specifications, compatibility, and budget. By selecting the right calibrator for your needs, you can ensure accurate and reliable diagnostic results, ultimately improving patient care and research outcomes.

 Precautions

Proper handling and storage of the β2-Microglobulin Calibrator are essential to maintain its stability and ensure accurate calibration results.

1. Storage Conditions: Store the calibrator at the recommended temperature to prevent degradation and ensure long-term stability.
2. Handling Procedures: Follow proper handling procedures to avoid contamination, which could compromise the accuracy of the calibrator.
3. Expiration Date: Always check the expiration date before use, as expired calibrators may not provide accurate results.
4. Compatibility: Ensure that the calibrator is compatible with your specific assay kit and diagnostic equipment to avoid errors in measurement.
5. Safety Precautions: Use appropriate personal protective equipment when handling the calibrator, especially if it contains hazardous materials like sodium azide.

The β2-Microglobulin Calibrator requires careful handling and storage to maintain its effectiveness. By following the recommended precautions, you can ensure that the calibrator provides accurate and reliable results, supporting high-quality diagnostic testing and patient care.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list