Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
α-Amylase Assay Kit (EPS Substrate Method)
The α-Amylase Assay Kit is a liquid reagent system designed for the quantitative determination of α-amylase activity in serum, plasma, or urine. It consists of two main components: Reagent I (R1) and Reagent II (R2). R1 contains HEPES buffer, calcium chloride, α-glucosidase, and sodium chloride, while R2 includes HEPES buffer and EPS substrate. This kit is widely used in clinical laboratories for accurate and reliable measurement of α-amylase levels.
Product English Name:
α-Amylase Assay Kit (EPS Substrate Method)
Alias:
Amylase Test Kit,EPS Amylase Kit
Intended Use:
This kit is specifically designed for in vitro diagnostic use to measure the concentration of α-amylase in serum, plasma, or urine samples. It is commonly employed in clinical settings to assist in the diagnosis and monitoring of pancreatic and salivary gland disorders, as well as other conditions that may affect α-amylase levels.
Product Introduction

The α-Amylase Assay Kit (EPS Substrate Method) is a high-quality diagnostic tool used to measure α-amylase activity in biological samples. This kit is essential for clinical laboratories, providing accurate and reproducible results. It is particularly useful in diagnosing pancreatic and salivary gland diseases, as well as monitoring treatment efficacy. The kit's liquid reagent format ensures ease of use and stability, making it a reliable choice for routine testing.

1. The α-Amylase Assay Kit is characterized by its high sensitivity and specificity, ensuring precise measurement of α-amylase levels. The use of EPS substrate enhances the accuracy of the assay, making it suitable for both clinical and research applications.
2. The kit is composed of two main reagents: Reagent I (R1) and Reagent II (R2). R1 contains HEPES buffer, calcium chloride, α-glucosidase, and sodium chloride, while R2 includes HEPES buffer and EPS substrate. This combination ensures optimal conditions for the enzymatic reaction, leading to reliable results.
3. The primary use of this kit is to measure α-amylase activity in serum, plasma, or urine samples. It is widely used in clinical laboratories to diagnose and monitor pancreatic and salivary gland disorders, as well as other conditions that may affect α-amylase levels.

The α-Amylase Assay Kit (EPS Substrate Method) is a vital tool in clinical diagnostics, offering high sensitivity and specificity for measuring α-amylase levels. Its liquid reagent format and precise composition make it a reliable choice for laboratories. Whether diagnosing pancreatic disorders or monitoring treatment, this kit provides accurate and reproducible results, ensuring confidence in clinical decision-making.

Main Features

The α-Amylase Assay Kit offers high sensitivity, specificity, and ease of use, making it an essential tool for clinical laboratories. Its liquid reagent format ensures stability and reliability, while the EPS substrate enhances assay accuracy.

1. High Sensitivity: The kit is designed to detect even low levels of α-amylase, ensuring accurate results in clinical samples.
2. Specificity: The use of EPS substrate ensures that the assay specifically measures α-amylase activity, minimizing interference from other enzymes.
3. Ease of Use: The liquid reagent format simplifies the assay procedure, making it suitable for routine laboratory use.
4. Stability: The reagents are stable under recommended storage conditions, ensuring consistent performance over time.
5. Reproducibility: The kit provides consistent and reproducible results, essential for reliable clinical diagnostics.

The α-Amylase Assay Kit stands out for its high sensitivity, specificity, and ease of use. Its liquid reagent format and stable composition make it a reliable choice for clinical laboratories. Whether used for routine testing or specialized diagnostics, this kit delivers consistent and accurate results, ensuring confidence in clinical decision-making.

Clinical Applications

The α-Amylase Assay Kit is widely used in clinical settings to diagnose and monitor pancreatic and salivary gland disorders. It is also employed in research to study α-amylase activity in various biological samples.

1. Pancreatic Disorders: The kit is commonly used to diagnose acute and chronic pancreatitis, as well as other pancreatic conditions that affect α-amylase levels.
2. Salivary Gland Disorders: It is also used to diagnose salivary gland diseases, such as sialadenitis, where α-amylase levels may be elevated.
3. Monitoring Treatment: The kit is employed to monitor the effectiveness of treatment for pancreatic and salivary gland disorders, providing valuable information on patient progress.
4. Research Applications: In addition to clinical use, the kit is used in research to study α-amylase activity in various biological samples, contributing to a better understanding of enzyme function.
5. Routine Testing: The kit is suitable for routine testing in clinical laboratories, providing reliable results for patient diagnosis and management.

The α-Amylase Assay Kit is a versatile tool in clinical diagnostics, used to diagnose and monitor pancreatic and salivary gland disorders. Its applications extend to research, where it contributes to the study of α-amylase activity. Whether used in routine testing or specialized diagnostics, this kit provides reliable and accurate results, supporting effective patient care.

Purchasing Guide

When purchasing the α-Amylase Assay Kit, consider factors such as product specifications, types, budget, and intended use to ensure the best fit for your laboratory needs.

1. Product Specifications: Review the kit's specifications, including sensitivity, specificity, and stability, to ensure it meets your laboratory's requirements.
2. Product Types: Choose the appropriate kit type based on your laboratory's testing volume and specific diagnostic needs.
3. Budget: Consider your budget when selecting a kit, balancing cost with the need for high-quality, reliable results.
4. Intended Use: Ensure the kit is suitable for your intended applications, whether for routine testing, specialized diagnostics, or research.

Selecting the right α-Amylase Assay Kit involves careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can ensure that the kit meets your laboratory's needs, providing reliable and accurate results for patient care and research.

 Precautions

Proper handling and storage of the α-Amylase Assay Kit are essential to ensure accurate results and maintain reagent stability. Follow all instructions carefully to avoid contamination and ensure optimal performance.

1. Storage Conditions: Store the kit at the recommended temperature to maintain reagent stability and ensure consistent performance.
2. Handling: Handle reagents with care, avoiding contamination and ensuring proper mixing before use.
3. Calibration: Regularly calibrate equipment used with the kit to ensure accurate and reproducible results.
4. Quality Control: Perform quality control checks to verify the kit's performance and ensure reliable results.
5. Disposal: Dispose of used reagents and samples according to local regulations to ensure safety and environmental compliance.

Proper handling, storage, and use of the α-Amylase Assay Kit are crucial for maintaining its performance and ensuring accurate results. By following recommended procedures and precautions, you can maximize the kit's reliability and contribute to effective patient care and research outcomes.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files