Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
Amylase_2 (AMY_2)
The Amylase_2 (AMY_2) kit consists of two main reagents: Reagent 1 contains α-glucosidase and sodium azide, while Reagent 2 includes Ethylidene-4-NP-G7 and sodium azide. These components are designed to work together to measure amylase activity in biological samples. The kit is specifically formulated for laboratory use and requires careful handling due to the presence of sodium azide, a potentially hazardous substance.
Product English Name:
Amylase_2 (AMY_2)
Alias:
Alpha-Amylase Assay Kit,EPS Substrate Method Kit
Intended Use:
This product is intended for the in vitro quantitative determination of amylase activity in human serum, plasma (lithium heparin), and urine. It is commonly used in clinical diagnostics to assess pancreatic function and diagnose conditions such as pancreatitis, salivary gland disorders, and other amylase-related abnormalities.
Product Introduction

The Amylase_2 (AMY_2) kit is a state-of-the-art diagnostic tool designed for accurate measurement of amylase activity in biological fluids. Utilizing the EPS substrate method, this kit offers high sensitivity and specificity, making it a reliable choice for clinical laboratories. Its ease of use and consistent performance have made it a preferred option for healthcare professionals worldwide.

1. The Amylase_2 (AMY_2) kit is known for its precision and reliability. It employs a unique EPS substrate method that ensures accurate results even at low amylase concentrations. The kit is designed to minimize interference from other enzymes, providing a clear and specific measurement of amylase activity.
2. The kit consists of two reagents: Reagent 1 contains α-glucosidase and sodium azide, while Reagent 2 includes Ethylidene-4-NP-G7 and sodium azide. These components work synergistically to break down the substrate and produce a measurable signal, which correlates with amylase activity in the sample.
3. The primary use of the Amylase_2 (AMY_2) kit is to measure amylase activity in human serum, plasma, and urine. This measurement is crucial for diagnosing pancreatic and salivary gland disorders, as well as monitoring the progression of related diseases. The kit is widely used in clinical settings due to its accuracy and ease of use.

The Amylase_2 (AMY_2) kit, also known as the Alpha-Amylase Assay Kit, is a highly reliable diagnostic tool for measuring amylase activity. Its unique composition and method ensure accurate results, making it indispensable in clinical diagnostics. Whether you're diagnosing pancreatitis or monitoring salivary gland function, this kit is a trusted choice for healthcare professionals.

Main Features

The Amylase_2 (AMY_2) kit offers high sensitivity, specificity, and ease of use, making it a top choice for clinical laboratories. Its EPS substrate method ensures accurate measurement of amylase activity, even in complex biological samples.

1. High Sensitivity: The kit is designed to detect even low levels of amylase activity, ensuring accurate results in a wide range of clinical scenarios.
2. Specificity: The EPS substrate method minimizes interference from other enzymes, providing a clear and specific measurement of amylase activity.
3. Ease of Use: The kit comes with clear instructions and is easy to set up, making it suitable for both experienced and novice laboratory technicians.
4. Reliability: Consistent performance and reproducible results make this kit a trusted choice for clinical diagnostics.
5. Versatility: The kit can be used with various biological samples, including serum, plasma, and urine, making it a versatile tool for different diagnostic needs.

The Amylase_2 (AMY_2) kit stands out for its high sensitivity, specificity, and ease of use. Its reliable performance and versatility make it an essential tool for clinical laboratories, ensuring accurate diagnosis and monitoring of amylase-related conditions.

Clinical Applications

The Amylase_2 (AMY_2) kit is widely used in clinical settings to diagnose and monitor pancreatic and salivary gland disorders. Its accurate measurement of amylase activity is crucial for effective patient management.

1. Pancreatitis Diagnosis: The kit is commonly used to diagnose acute and chronic pancreatitis by measuring elevated amylase levels in serum or plasma.
2. Salivary Gland Disorders: It helps in diagnosing conditions affecting the salivary glands, such as sialadenitis, by measuring amylase activity in saliva or serum.
3. Monitoring Disease Progression: The kit is used to monitor the progression of pancreatic and salivary gland diseases, providing valuable information for treatment adjustments.
4. Post-Surgical Monitoring: After pancreatic or salivary gland surgery, the kit helps in monitoring amylase levels to ensure proper recovery and detect any complications.
5. Research Applications: Beyond clinical diagnostics, the kit is also used in research settings to study amylase activity in various biological samples.

The Amylase_2 (AMY_2) kit is a versatile tool in clinical diagnostics, essential for diagnosing and monitoring pancreatic and salivary gland disorders. Its accurate and reliable measurements provide critical insights for effective patient care and research.

Purchasing Guide

When purchasing the Amylase_2 (AMY_2) kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your laboratory's needs.

1. Product Specifications: Review the kit's components, sensitivity, and specificity to ensure it aligns with your diagnostic requirements.
2. Product Types: Choose between different versions of the kit, such as those optimized for specific sample types or with varying reagent volumes.
3. Budget: Consider the cost per test and overall budget to ensure the kit is economically viable for your laboratory.
4. Usage Scenarios: Evaluate the kit's suitability for your intended applications, whether for routine diagnostics, research, or specialized clinical settings.

Purchasing the Amylase_2 (AMY_2) kit requires careful consideration of its specifications, types, and cost. By aligning these factors with your laboratory's needs, you can ensure optimal performance and value for your diagnostic and research applications.

 Precautions

Proper handling and storage of the Amylase_2 (AMY_2) kit are essential to ensure accurate results and user safety. Follow all instructions and safety guidelines provided in the kit's manual.

1. Storage Conditions: Store the kit at the recommended temperature to maintain reagent stability and performance.
2. Handling: Use appropriate personal protective equipment (PPE) when handling reagents, especially those containing sodium azide.
3. Contamination Prevention: Avoid cross-contamination by using clean pipettes and disposable tips for each sample.
4. Disposal: Dispose of used reagents and samples according to local regulations and safety guidelines.
5. Calibration: Regularly calibrate equipment used with the kit to ensure accurate and consistent results.

The Amylase_2 (AMY_2) kit requires careful handling and storage to ensure accurate results and user safety. By following the provided guidelines and precautions, you can maximize the kit's performance and maintain a safe laboratory environment.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs: