Alpha-1 Acid Glycoprotein Assay Kit (Immunoturbidimetric Method)
The Alpha-1 Acid Glycoprotein Assay Kit is composed of two main reagents: Reagent 1 (R1) containing Tris buffer (pH 7.5, 50 mmol/L) and Reagent 2 (R2) containing Tris buffer (pH 7.5, 50 mmol/L) and goat-derived alpha-1 acid glycoprotein antibody (approximately 3.0 g/L). The kit also includes six calibrators and two control samples, all containing human-derived alpha-1 acid glycoprotein at varying concentrations, stabilized with sodium chloride (9.0 g/L).
Product English Name:
Alpha-1 Acid Glycoprotein Assay Kit (Immunoturbidimetric Method)
Alias:
AAG Assay Kit,AGP Test Kit
Intended Use:
This kit is designed for the quantitative determination of alpha-1 acid glycoprotein (AAG) levels in human serum. It is widely used in clinical laboratories to assess inflammatory conditions, monitor disease progression, and evaluate therapeutic responses.
Product Introduction

The Alpha-1 Acid Glycoprotein Assay Kit is a reliable and accurate tool for measuring AAG levels in human serum. Utilizing the immunoturbidimetric method, this kit ensures high sensitivity and specificity, making it an essential diagnostic tool in clinical settings. The kit includes all necessary reagents, calibrators, and controls, ensuring consistent and reproducible results.

1. The kit features a highly sensitive immunoturbidimetric method, which allows for precise measurement of AAG levels. This method is known for its accuracy and reliability in clinical diagnostics.
2. The composition of the kit includes two main reagents: R1 and R2. R1 contains a Tris buffer, while R2 contains both the Tris buffer and a goat-derived alpha-1 acid glycoprotein antibody. The kit also includes six calibrators and two control samples, all of which are essential for accurate calibration and quality control.
3. The primary use of this kit is to quantitatively determine the levels of alpha-1 acid glycoprotein in human serum. This measurement is crucial for diagnosing and monitoring various inflammatory conditions and diseases.

The Alpha-1 Acid Glycoprotein Assay Kit, also known as the AAG Assay Kit, is a vital tool in clinical diagnostics. Its precise immunoturbidimetric method, combined with a well-structured composition, ensures accurate and reliable results. This kit is indispensable for healthcare professionals aiming to monitor and diagnose inflammatory conditions effectively.

Main Features

The Alpha-1 Acid Glycoprotein Assay Kit offers high sensitivity and specificity in measuring AAG levels. It includes all necessary components for accurate and reproducible results, making it a reliable choice for clinical laboratories.

1. High Sensitivity: The immunoturbidimetric method ensures precise detection of low AAG levels, making it suitable for early diagnosis.
2. Specificity: The goat-derived antibody in R2 specifically targets alpha-1 acid glycoprotein, minimizing cross-reactivity with other proteins.
3. Comprehensive Calibration: The kit includes six calibrators, allowing for a wide range of AAG concentration measurements.
4. Quality Control: Two control samples are provided to ensure the accuracy and consistency of test results.
5. Ease of Use: The kit is designed for straightforward application in clinical laboratories, with clear instructions and minimal preparation required.

The Alpha-1 Acid Glycoprotein Assay Kit stands out for its high sensitivity, specificity, and comprehensive calibration options. Its user-friendly design and reliable performance make it an essential tool for clinical diagnostics, ensuring accurate and consistent results in the measurement of AAG levels.

Clinical Applications

The Alpha-1 Acid Glycoprotein Assay Kit is widely used in clinical settings to monitor inflammatory conditions, assess disease progression, and evaluate therapeutic responses. Its accurate measurement of AAG levels is crucial for patient management.

1. Inflammatory Conditions: The kit is used to monitor AAG levels in patients with chronic inflammatory diseases, providing insights into disease activity.
2. Disease Progression: By measuring AAG levels, clinicians can assess the progression of diseases such as rheumatoid arthritis and lupus.
3. Therapeutic Monitoring: The kit helps evaluate the effectiveness of anti-inflammatory treatments by tracking changes in AAG levels over time.
4. Diagnostic Tool: Elevated AAG levels can indicate acute-phase responses, aiding in the diagnosis of infections and other inflammatory conditions.
5. Research Applications: The kit is also used in research studies to explore the role of AAG in various diseases and therapeutic interventions.

The Alpha-1 Acid Glycoprotein Assay Kit is a versatile tool in clinical practice, offering valuable insights into inflammatory conditions, disease progression, and therapeutic responses. Its accurate and reliable measurements make it indispensable for patient care and research.

Purchasing Guide

When purchasing the Alpha-1 Acid Glycoprotein Assay Kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your clinical laboratory needs.

1. Product Specifications: Review the kit's components, including reagents, calibrators, and controls, to ensure they meet your laboratory's requirements.
2. Product Types: Choose between different kit sizes or configurations based on your laboratory's testing volume and storage capacity.
3. Budget: Consider the cost of the kit, including any additional expenses for calibration or quality control materials.
4. Usage Scenarios: Evaluate the kit's suitability for your specific clinical applications, such as routine diagnostics or research purposes.

Purchasing the Alpha-1 Acid Glycoprotein Assay Kit requires careful consideration of product specifications, types, budget, and intended use. By selecting the right kit, you can ensure accurate and reliable AAG measurements in your clinical laboratory.

 Precautions

Proper handling and storage of the Alpha-1 Acid Glycoprotein Assay Kit are essential to ensure accurate results and maintain the integrity of its components.

1. Storage Conditions: Store the kit at the recommended temperature to preserve the stability of reagents and controls.
2. Handling: Follow the manufacturer's instructions for handling and preparing the kit components to avoid contamination or degradation.
3. Expiration Date: Always check the expiration date before use to ensure the kit's components are still effective.
4. Quality Control: Regularly perform quality control tests to verify the accuracy and consistency of the kit's performance.
5. Disposal: Dispose of used reagents and materials according to local regulations to ensure safety and environmental compliance.

To maintain the accuracy and reliability of the Alpha-1 Acid Glycoprotein Assay Kit, it is crucial to follow proper storage, handling, and disposal procedures. Regular quality control checks and adherence to expiration dates further ensure the kit's optimal performance in clinical diagnostics.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files