25-Hydroxy Vitamin D (25-OH-VD) Assay Kit (Quantum Dot Immunofluorescence Method)
The 25-Hydroxy Vitamin D Assay Kit is composed of a detection card and a calibration card. The detection card includes a test strip made up of a sample pad, a conjugate pad (coated with quantum dot-labeled 25-OH-VD antibody and quantum dot-labeled chicken IgY antibody), a membrane (coated with 25-OH-VD antigen on the test line and goat anti-chicken IgY antibody on the control line), absorbent paper, and a backing card. The calibration card contains the standard curve data for the batch and an instruction manual.
Product English Name:
25-Hydroxy Vitamin D (25-OH-VD) Assay Kit (Quantum Dot Immunofluorescence Method)
Alias:
25-OH-VD Test Kit,Vitamin D Quantification Kit
Intended Use:
This kit is intended for the quantitative determination of 25-hydroxy vitamin D levels in human serum, plasma, or whole blood. It is used in clinical settings to assess vitamin D status, which is crucial for bone health, immune function, and overall well-being.
Product Introduction

The 25-Hydroxy Vitamin D Assay Kit utilizes quantum dot immunofluorescence technology to provide accurate and reliable measurements of 25-OH-VD levels. This kit is designed for clinical laboratories and research institutions to evaluate vitamin D status, which is essential for diagnosing and managing conditions related to vitamin D deficiency or excess.

1. The kit features advanced quantum dot immunofluorescence technology, ensuring high sensitivity and specificity in detecting 25-OH-VD levels. This method offers superior performance compared to traditional immunoassays.
2. The test strip is composed of multiple layers, including a sample pad, conjugate pad, membrane, absorbent paper, and backing card. Each component is carefully designed to ensure optimal performance and accurate results.
3. The kit is used for quantitative determination of 25-OH-VD in human serum, plasma, or whole blood. It is widely applied in clinical diagnostics to assess vitamin D status, which is critical for bone health, immune function, and overall health management.

The 25-Hydroxy Vitamin D Assay Kit, also known as the Vitamin D Quantification Kit, is a cutting-edge tool for measuring vitamin D levels. Its advanced technology and precise composition make it an essential device for clinical diagnostics and research.

Main Features

The 25-Hydroxy Vitamin D Assay Kit offers high sensitivity, specificity, and accuracy in measuring 25-OH-VD levels. It is designed for ease of use and reliable performance in clinical and research settings.

1. High Sensitivity: The quantum dot immunofluorescence technology ensures the detection of low concentrations of 25-OH-VD, making it suitable for early diagnosis and monitoring.
2. Specificity: The kit is highly specific to 25-OH-VD, minimizing cross-reactivity with other substances and ensuring accurate results.
3. User-Friendly: The kit is designed for easy operation, with clear instructions and a straightforward workflow, making it accessible for both experienced and novice users.
4. Reliable Performance: The kit provides consistent and reproducible results, ensuring confidence in clinical decision-making.
5. Comprehensive Calibration: The included calibration card with standard curve data ensures accurate quantification across a wide range of concentrations.

The 25-Hydroxy Vitamin D Assay Kit stands out for its high sensitivity, specificity, and user-friendly design. Its reliable performance and comprehensive calibration make it an indispensable tool for clinical diagnostics and research.

Clinical Applications

The 25-Hydroxy Vitamin D Assay Kit is widely used in clinical settings to assess vitamin D status, which is crucial for diagnosing and managing conditions related to vitamin D deficiency or excess.

1. Diagnosis of Vitamin D Deficiency: The kit is used to diagnose vitamin D deficiency, which is associated with conditions such as osteoporosis, rickets, and osteomalacia.
2. Monitoring Vitamin D Therapy: It is used to monitor the effectiveness of vitamin D supplementation or therapy in patients with deficiency or related conditions.
3. Research Applications: The kit is also used in research studies to investigate the role of vitamin D in various diseases and health conditions.
4. Public Health Screening: It is employed in large-scale screening programs to assess the vitamin D status of populations and identify at-risk groups.
5. Clinical Trials: The kit is used in clinical trials to evaluate the impact of new treatments or interventions on vitamin D levels.

The 25-Hydroxy Vitamin D Assay Kit is a versatile tool in clinical practice and research. Its applications range from diagnosing vitamin D deficiency to monitoring therapy and conducting research, making it an essential component of modern healthcare.

Purchasing Guide

When purchasing the 25-Hydroxy Vitamin D Assay Kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your needs.

1. Product Specifications: Review the kit's performance indicators, including sensitivity, specificity, and accuracy, to ensure it meets your laboratory's standards.
2. Product Types: Choose the appropriate kit type based on your sample type (serum, plasma, or whole blood) and testing requirements.
3. Budget: Consider the cost of the kit, including any additional reagents or equipment needed, and ensure it fits within your budget.
4. Usage Scenarios: Evaluate the kit's suitability for your intended use, whether for clinical diagnostics, research, or public health screening.

Purchasing the 25-Hydroxy Vitamin D Assay Kit requires careful consideration of product specifications, types, budget, and usage scenarios. By evaluating these factors, you can ensure the kit meets your needs and delivers reliable results.

 Precautions

When using the 25-Hydroxy Vitamin D Assay Kit, it is important to follow the instructions carefully and take necessary precautions to ensure accurate and safe results.

1. Proper Storage: Store the kit at the recommended temperature to maintain its stability and performance.
2. Sample Handling: Handle samples with care to avoid contamination or degradation, which could affect the results.
3. Calibration: Ensure the calibration card is used correctly to maintain the accuracy of the standard curve.
4. Safety Measures: Follow laboratory safety protocols when handling reagents and samples to prevent exposure or accidents.
5. Quality Control: Perform regular quality control checks to ensure the kit is functioning properly and delivering reliable results.

Using the 25-Hydroxy Vitamin D Assay Kit requires attention to storage, sample handling, calibration, safety, and quality control. By following these precautions, you can ensure accurate and safe results, making the kit a reliable tool in clinical and research settings.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list