α1-Antitrypsin Detection Kit (Immunoturbidimetric Method)
The α1-Antitrypsin Detection Kit is composed of Reagent R1, Reagent R2, Calibrator, and Control. Reagent R1 contains a phosphate buffer (50 mmoL/L) and polyethylene glycol (6%). Reagent R2 includes α1-antitrypsin antibody (100mL/L) and a phosphate buffer (50 mmoL/L). The Calibrator and Control both contain α1-antitrypsin antigen with specified values and a phosphate buffer (50 mmoL/L).
Product English Name:
α1-Antitrypsin Detection Kit (Immunoturbidimetric Method)
Alias:
AAT Kit,Alpha-1 Antitrypsin Test Kit
Intended Use:
This kit is designed for the quantitative detection of α1-antitrypsin levels in human serum, primarily used in clinical settings to assess and monitor conditions related to α1-antitrypsin deficiency.
Product Introduction

The α1-Antitrypsin Detection Kit is a vital tool in clinical diagnostics, specifically designed to measure the concentration of α1-antitrypsin in human serum. This protein plays a crucial role in protecting tissues from enzymes released by inflammatory cells. The kit employs an immunoturbidimetric method, ensuring high accuracy and reliability in results. It is widely used in hospitals and diagnostic laboratories to aid in the diagnosis and management of conditions such as emphysema and liver disease.

1. The kit features a highly sensitive immunoturbidimetric method, which allows for precise measurement of α1-antitrypsin levels. This method is known for its accuracy and reproducibility, making it a preferred choice in clinical diagnostics.
2. The composition of the kit includes Reagent R1, Reagent R2, a Calibrator, and a Control. Each component is carefully formulated to ensure optimal performance. Reagent R1 contains a phosphate buffer and polyethylene glycol, while Reagent R2 includes α1-antitrypsin antibody and a phosphate buffer. The Calibrator and Control both contain α1-antitrypsin antigen with specified values.
3. The primary use of this kit is for the quantitative detection of α1-antitrypsin in human serum. It is particularly useful in diagnosing and monitoring conditions related to α1-antitrypsin deficiency, such as emphysema and liver disease. The kit is designed for use in clinical laboratories and is an essential tool for healthcare professionals.

The α1-Antitrypsin Detection Kit, also known as the AAT Kit, is a critical diagnostic tool in clinical settings. It is designed to measure the levels of α1-antitrypsin in human serum, which is essential for diagnosing and managing conditions like emphysema and liver disease. The kit's composition and method ensure high accuracy and reliability, making it a trusted choice for healthcare professionals.

Main Features

The α1-Antitrypsin Detection Kit offers high sensitivity and accuracy in measuring α1-antitrypsin levels. It is designed for ease of use in clinical laboratories, providing reliable results for diagnosing and monitoring α1-antitrypsin deficiency-related conditions.

1. The kit utilizes an immunoturbidimetric method, which is highly sensitive and specific for detecting α1-antitrypsin levels. This method ensures accurate and reproducible results, making it ideal for clinical diagnostics.
2. The kit includes Reagent R1 and Reagent R2, both of which are essential for the detection process. Reagent R1 contains a phosphate buffer and polyethylene glycol, while Reagent R2 includes α1-antitrypsin antibody and a phosphate buffer. These components work together to ensure optimal performance.
3. The Calibrator and Control included in the kit are crucial for standardizing the test results. They contain α1-antitrypsin antigen with specified values, allowing for accurate calibration and quality control during the testing process.
4. The kit is designed for use in clinical laboratories and is easy to use. It provides clear instructions and requires minimal training, making it accessible to a wide range of healthcare professionals.
5. The primary function of the kit is to measure α1-antitrypsin levels in human serum. This is particularly important for diagnosing and monitoring conditions related to α1-antitrypsin deficiency, such as emphysema and liver disease.

The α1-Antitrypsin Detection Kit is a reliable and accurate tool for measuring α1-antitrypsin levels in human serum. Its main features include high sensitivity, ease of use, and the ability to provide reproducible results. These features make it an essential tool for diagnosing and managing α1-antitrypsin deficiency-related conditions.

Clinical Applications

The α1-Antitrypsin Detection Kit is widely used in clinical settings for the diagnosis and monitoring of α1-antitrypsin deficiency-related conditions, such as emphysema and liver disease.

1. The kit is primarily used in clinical laboratories for the quantitative detection of α1-antitrypsin in human serum. This is essential for diagnosing conditions related to α1-antitrypsin deficiency.
2. In clinical practice, the kit is used to monitor patients with known α1-antitrypsin deficiency. Regular testing helps healthcare professionals assess the progression of the disease and adjust treatment plans accordingly.
3. The kit is also used in research settings to study the role of α1-antitrypsin in various diseases. Researchers use the kit to measure α1-antitrypsin levels in different patient populations, providing valuable insights into disease mechanisms.
4. In addition to its diagnostic and monitoring applications, the kit is used in quality control processes in clinical laboratories. The Calibrator and Control included in the kit ensure that test results are accurate and reliable.
5. The kit is also used in epidemiological studies to assess the prevalence of α1-antitrypsin deficiency in different populations. This information is crucial for public health planning and resource allocation.

The α1-Antitrypsin Detection Kit has a wide range of clinical applications, from diagnosing and monitoring α1-antitrypsin deficiency to supporting research and quality control in clinical laboratories. Its versatility and reliability make it an indispensable tool in healthcare.

Purchasing Guide

When purchasing the α1-Antitrypsin Detection Kit, it is important to consider product specifications, types, budget, and usage scenarios to ensure it meets your clinical needs.

1. Product specifications are crucial when selecting the kit. Ensure that the kit includes all necessary components, such as Reagent R1, Reagent R2, Calibrator, and Control, and that they meet the required standards for clinical use.
2. There are different types of α1-Antitrypsin Detection Kits available, each designed for specific applications. Choose a kit that aligns with your clinical needs, whether for routine diagnostics, research, or quality control.
3. Budget considerations are important when purchasing the kit. While cost is a factor, it is essential to balance it with the kit's quality and reliability to ensure accurate and reproducible results.
4. Consider the usage scenarios when selecting the kit. Ensure that the kit is suitable for your laboratory's workflow and that it can be easily integrated into your existing processes.

Purchasing the α1-Antitrypsin Detection Kit requires careful consideration of product specifications, types, budget, and usage scenarios. By taking these factors into account, you can ensure that the kit meets your clinical needs and provides reliable results.

 Precautions

When using the α1-Antitrypsin Detection Kit, it is important to follow all safety and handling precautions to ensure accurate results and prevent contamination.

1. Always wear appropriate personal protective equipment (PPE), such as gloves and lab coats, when handling the kit components. This helps prevent contamination and ensures safety.
2. Follow the manufacturer's instructions carefully when preparing and using the kit. Improper handling or preparation can lead to inaccurate results.
3. Store the kit components according to the manufacturer's recommendations. Proper storage conditions are essential for maintaining the integrity and performance of the reagents.
4. Dispose of all used materials and waste according to local regulations and laboratory protocols. Proper disposal helps prevent contamination and ensures safety.
5. Regularly calibrate and maintain the equipment used with the kit to ensure accurate and reliable results. This includes pipettes, centrifuges, and analyzers.

Using the α1-Antitrypsin Detection Kit requires adherence to safety and handling precautions to ensure accurate results and prevent contamination. By following these guidelines, you can maintain the integrity of the kit and ensure the safety of laboratory personnel.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files