The 25-Hydroxy Vitamin D Assay Kit is a sophisticated diagnostic tool that employs time-resolved fluorescence immunochromatography to accurately measure vitamin D levels in human samples. This method ensures high sensitivity and specificity, making it a reliable choice for clinical laboratories. The kit is designed for ease of use, with a straightforward procedure that yields quick and accurate results.
1. The kit features a unique test card design that integrates multiple components to ensure precise and reliable results. The test strip is engineered with a sample pad, conjugate pad, nitrocellulose membrane, absorbent pad, and PVC backing, all working in harmony to facilitate the detection process.
2. The composition of the kit includes a sample processing solution and an ID card. The sample processing solution is a 0.02M Tris buffer that aids in the preparation of samples, while the ID card stores essential information such as the project name, batch number, and calibration curve, ensuring traceability and accuracy.
3. The primary use of this kit is to quantitatively detect 25-hydroxy vitamin D levels in human serum, plasma, or whole blood. This is crucial for diagnosing and monitoring conditions related to vitamin D deficiency or excess, such as osteoporosis, rickets, and hypervitaminosis D.
The 25-Hydroxy Vitamin D Assay Kit, also known as the Vitamin D Assay Kit, is a comprehensive diagnostic tool that combines advanced technology with user-friendly design. Its unique composition and precise detection method make it an indispensable resource for clinical laboratories aiming to assess vitamin D status accurately.
The 25-Hydroxy Vitamin D Assay Kit offers high sensitivity and specificity in detecting vitamin D levels, making it a reliable choice for clinical diagnostics. Its user-friendly design and quick results make it a preferred tool in laboratories.
1. High Sensitivity: The kit employs time-resolved fluorescence immunochromatography, ensuring accurate detection of even low levels of 25-hydroxy vitamin D.
2. Specificity: The use of monoclonal antibodies and specific antigens ensures that the kit detects only 25-hydroxy vitamin D, minimizing cross-reactivity with other substances.
3. Ease of Use: The kit is designed for straightforward operation, with clear instructions and minimal steps required for sample processing.
4. Quick Results: The assay provides results in a short time frame, allowing for rapid diagnosis and treatment decisions.
5. Traceability: The inclusion of an ID card with project name, batch number, and calibration curve ensures that each test is traceable and reliable.
The 25-Hydroxy Vitamin D Assay Kit stands out for its high sensitivity, specificity, and ease of use. Its ability to provide quick and accurate results makes it an essential tool in clinical diagnostics, particularly for assessing vitamin D status.
The 25-Hydroxy Vitamin D Assay Kit is widely used in clinical settings to diagnose and monitor vitamin D-related conditions. Its accuracy and reliability make it a valuable tool for healthcare professionals.
1. Diagnosis of Vitamin D Deficiency: The kit is used to identify individuals with low levels of 25-hydroxy vitamin D, which is crucial for diagnosing conditions like osteoporosis and rickets.
2. Monitoring Vitamin D Therapy: Healthcare providers use the kit to monitor the effectiveness of vitamin D supplementation in patients with deficiency.
3. Research Applications: The kit is also used in clinical research to study the role of vitamin D in various health conditions.
4. Public Health Screening: The kit is employed in large-scale screening programs to assess the vitamin D status of populations.
5. Personalized Medicine: The kit aids in tailoring vitamin D supplementation to individual needs, ensuring optimal health outcomes.
The 25-Hydroxy Vitamin D Assay Kit is a versatile tool in clinical practice, used for diagnosing, monitoring, and researching vitamin D-related conditions. Its accuracy and reliability make it indispensable in healthcare settings.
When purchasing the 25-Hydroxy Vitamin D Assay Kit, consider factors such as product specifications, types, budget, and intended use to ensure you select the right kit for your needs.
1. Product Specifications: Evaluate the kit's sensitivity, specificity, and detection range to ensure it meets your diagnostic requirements.
2. Product Types: Choose between different kit formats, such as single-use or multi-use, based on your laboratory's workflow and sample volume.
3. Budget: Consider the cost per test and the overall budget for your laboratory when selecting a kit.
4. Intended Use: Ensure the kit is suitable for your specific application, whether it's clinical diagnostics, research, or public health screening.
Selecting the right 25-Hydroxy Vitamin D Assay Kit involves careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can ensure that the kit meets your laboratory's needs and provides reliable results.
Proper handling and storage of the 25-Hydroxy Vitamin D Assay Kit are essential to ensure accurate results and maintain the integrity of the components.
1. Storage Conditions: Store the kit at the recommended temperature to prevent degradation of the components.
2. Handling: Follow the manufacturer's instructions for handling the kit to avoid contamination or damage to the test strips.
3. Sample Preparation: Ensure that samples are prepared correctly to avoid errors in the assay results.
4. Calibration: Regularly calibrate the kit using the provided ID card to maintain accuracy.
5. Disposal: Dispose of used components according to local regulations to ensure safety and environmental compliance.
To ensure the accuracy and reliability of the 25-Hydroxy Vitamin D Assay Kit, it is crucial to follow proper storage, handling, and disposal procedures. Adhering to these precautions will help maintain the integrity of the kit and provide consistent results.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.