The Alpha-1 Acid Glycoprotein (AAG) Assay Kit is a sophisticated diagnostic tool designed to measure the concentration of AAG in human serum. AAG is an acute-phase protein that increases in response to inflammation and other pathological conditions. This kit employs the immunoturbidimetric method, which is known for its accuracy and reliability. The kit includes all necessary reagents, calibrators, and controls to ensure precise and consistent results.
1. The kit features a highly specific anti-human alpha-1 acid glycoprotein antibody, ensuring accurate detection of AAG levels. The immunoturbidimetric method used in this kit is known for its high sensitivity and specificity, making it a reliable choice for clinical diagnostics.
2. The kit's composition includes two main reagents: Reagent 1, which contains phosphate buffer, polyethylene glycol 6000, and sodium chloride; and Reagent 2, which consists of Tris buffer, anti-human alpha-1 acid glycoprotein antibody, and sodium chloride. These components work together to provide a stable and accurate assay environment.
3. The primary use of this kit is for the quantitative determination of AAG in human serum. It is particularly useful in clinical settings for monitoring inflammatory conditions, liver diseases, and other conditions where AAG levels are indicative of disease progression or response to treatment.
The Alpha-1 Acid Glycoprotein (AAG) Assay Kit is a reliable and accurate tool for measuring AAG levels in human serum. Its high specificity and sensitivity make it an essential diagnostic tool in clinical settings. The kit's comprehensive composition ensures consistent and precise results, making it a valuable asset for healthcare professionals.
The AAG Assay Kit offers high sensitivity and specificity in detecting AAG levels, making it a reliable tool for clinical diagnostics. It includes all necessary components for accurate measurement and quality assurance.
1. The kit employs the immunoturbidimetric method, known for its high sensitivity and specificity, ensuring accurate detection of AAG levels in human serum.
2. It includes two main reagents: Reagent 1, containing phosphate buffer, polyethylene glycol 6000, and sodium chloride; and Reagent 2, consisting of Tris buffer, anti-human alpha-1 acid glycoprotein antibody, and sodium chloride.
3. The kit also includes calibrators and controls, which are essential for accurate measurement and quality assurance, ensuring consistent and reliable results.
4. The primary use of this kit is for the quantitative determination of AAG in human serum, particularly useful in monitoring inflammatory conditions and liver diseases.
5. The kit is designed for ease of use, with clear instructions and a straightforward protocol, making it accessible for healthcare professionals.
The AAG Assay Kit is a comprehensive and reliable tool for measuring AAG levels in human serum. Its high sensitivity, specificity, and ease of use make it an essential diagnostic tool in clinical settings. The inclusion of calibrators and controls ensures consistent and accurate results, making it a valuable asset for healthcare professionals.
The AAG Assay Kit is widely used in clinical settings for monitoring inflammatory conditions, liver diseases, and other conditions where AAG levels are indicative of disease progression or response to treatment.
1. The kit is used in clinical laboratories for the quantitative determination of AAG levels in human serum, providing valuable information for diagnosing and monitoring inflammatory conditions.
2. It is particularly useful in monitoring liver diseases, where AAG levels can indicate disease progression or response to treatment.
3. The kit is also used in research settings to study the role of AAG in various pathological conditions, providing insights into disease mechanisms and potential therapeutic targets.
4. In clinical practice, the kit is used to monitor patients with chronic inflammatory conditions, such as rheumatoid arthritis, to assess disease activity and response to therapy.
5. The kit is also used in emergency settings to quickly assess AAG levels in patients with acute inflammatory conditions, providing critical information for immediate medical intervention.
The AAG Assay Kit is a versatile tool used in various clinical and research settings. Its ability to accurately measure AAG levels makes it invaluable for diagnosing and monitoring inflammatory conditions, liver diseases, and other pathological states. The kit's reliability and ease of use ensure that healthcare professionals can quickly and accurately assess patient conditions, leading to better outcomes.
When purchasing the AAG Assay Kit, consider product specifications, types, budget, and intended use to ensure it meets your clinical or research needs.
1. Product parameters: Ensure the kit includes all necessary components, such as reagents, calibrators, and controls, and check the sensitivity and specificity of the assay.
2. Product types: Choose the appropriate kit type based on your specific needs, such as high-throughput or manual assays, and consider the volume of samples you will be processing.
3. Budget: Consider the cost of the kit, including any additional equipment or reagents needed, and ensure it fits within your budget while meeting your quality requirements.
4. Usage scenarios: Determine the intended use of the kit, whether for clinical diagnostics, research, or both, and ensure it is suitable for your specific application.
Purchasing the AAG Assay Kit requires careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can ensure that the kit meets your clinical or research needs, providing accurate and reliable results for your diagnostic or investigative purposes.
Proper handling and storage of the AAG Assay Kit are essential to ensure accurate results and maintain the integrity of the components.
1. Storage: Store the kit at the recommended temperature, typically 2-8°C, and ensure all components are properly sealed to prevent contamination or degradation.
2. Handling: Follow the manufacturer's instructions for handling the reagents and samples, and use appropriate personal protective equipment to avoid exposure to hazardous materials.
3. Calibration: Regularly calibrate the assay using the provided calibrators to ensure accurate and consistent results.
4. Quality Control: Use the provided controls to monitor the performance of the assay and ensure it is functioning correctly.
5. Disposal: Dispose of all waste materials according to local regulations and guidelines to prevent environmental contamination.
Proper handling, storage, and disposal of the AAG Assay Kit are crucial for maintaining the accuracy and reliability of the assay. By following the manufacturer's instructions and adhering to safety guidelines, you can ensure the integrity of the components and obtain consistent, accurate results for your diagnostic or research purposes.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.