The α-Hydroxybutyrate Dehydrogenase (DGKC Recommended Method) Kit is a high-quality diagnostic tool used to measure the activity of α-HBDH in human serum. This enzyme is crucial in the metabolism of hydroxybutyrate and is often used as a biomarker in clinical settings. The kit offers exceptional accuracy and precision, making it a reliable choice for laboratories.
1. The kit features a robust formulation that ensures stability and consistency across different batches. The inclusion of Tris buffer and NADH provides a controlled environment for accurate enzyme activity measurement.
2. The composition of the kit includes Tris buffer, α-ketobutyrate, and NADH, which are essential for the enzymatic reaction. These components are carefully balanced to ensure optimal performance and reliability.
3. The primary use of the kit is to measure α-HBDH activity in human serum, which is vital for diagnosing and monitoring various medical conditions. Its high linear range and precision make it suitable for both research and clinical applications.
The α-Hydroxybutyrate Dehydrogenase Kit, also known as the HBDH Kit, is a well-designed diagnostic tool that offers high accuracy and precision. Its carefully balanced composition ensures reliable results, making it an essential tool in clinical diagnostics.
The kit provides accurate and precise measurement of α-HBDH activity, with a wide linear range and high correlation coefficient, ensuring reliable results in clinical diagnostics.
1. The kit offers high accuracy with a deviation of no more than ±5% from the target value, ensuring reliable results in clinical settings.
2. It features excellent intra-assay precision with an RSD of ≤5%, making it suitable for repeated measurements within the same batch.
3. The inter-assay precision is also high, with an RSD of ≤6%, ensuring consistency across different batches and laboratories.
4. The linear range of the assay is between 5 to 1000 U/L, providing a broad spectrum for accurate measurement of enzyme activity.
5. The correlation coefficient (r²) of ≥0.995 ensures a strong linear relationship, making the kit highly reliable for quantitative analysis.
The α-Hydroxybutyrate Dehydrogenase Kit stands out for its high accuracy, precision, and broad linear range. These features make it an indispensable tool for clinical diagnostics, ensuring reliable and consistent results.
The kit is widely used in clinical laboratories for the quantitative determination of α-HBDH activity in human serum, aiding in the diagnosis and monitoring of various medical conditions.
1. The kit is used in the diagnosis of myocardial infarction, where elevated levels of α-HBDH can indicate heart muscle damage.
2. It is also employed in the assessment of liver diseases, as α-HBDH levels can be indicative of liver function and damage.
3. The kit is useful in monitoring the progression of certain cancers, where enzyme activity can serve as a biomarker.
4. It is used in research settings to study the metabolic pathways involving hydroxybutyrate and its derivatives.
5. The kit is also applied in the evaluation of muscle disorders, where changes in enzyme activity can reflect muscle health.
The α-Hydroxybutyrate Dehydrogenase Kit is a versatile tool in clinical diagnostics, aiding in the diagnosis and monitoring of various conditions such as myocardial infarction, liver diseases, and muscle disorders. Its reliability and precision make it a valuable asset in both clinical and research settings.
When purchasing the α-Hydroxybutyrate Dehydrogenase Kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your laboratory's needs.
1. Evaluate the product specifications, including accuracy, precision, and linear range, to ensure it aligns with your diagnostic requirements.
2. Consider the different types of kits available, such as those with varying buffer compositions or additional components, to find the best fit for your application.
3. Assess your budget and compare prices from different suppliers to ensure cost-effectiveness without compromising on quality.
4. Determine the intended use of the kit, whether for clinical diagnostics or research, to select the most appropriate product.
Purchasing the α-Hydroxybutyrate Dehydrogenase Kit requires careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can ensure that the kit meets your laboratory's needs and provides reliable results.
Proper handling and storage of the α-Hydroxybutyrate Dehydrogenase Kit are essential to maintain its performance and ensure accurate results.
1. Store the kit at the recommended temperature to preserve the stability of the reagents and ensure consistent performance.
2. Handle the reagents with care, avoiding contamination, to prevent any interference with the assay results.
3. Follow the manufacturer's instructions for reconstitution and use of the reagents to ensure accurate and reliable measurements.
4. Regularly calibrate the equipment used with the kit to maintain accuracy and precision in the assay results.
5. Dispose of used reagents and materials according to laboratory safety guidelines to prevent any potential hazards.
To ensure the optimal performance of the α-Hydroxybutyrate Dehydrogenase Kit, it is crucial to follow proper handling, storage, and disposal procedures. By adhering to these precautions, you can maintain the kit's reliability and accuracy in clinical diagnostics.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.