Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
α-Amylase Assay Kit (p-Nitrophenyl Maltotriose Method)
The α-Amylase Assay Kit is composed of two main reagents. Reagent 1 contains HEPES buffer, calcium chloride, and α-glucosidase, while Reagent 2 includes p-nitrophenyl maltotriose and HEPES buffer. These components work together to facilitate the accurate measurement of α-amylase activity in human serum or plasma samples.
Product English Name:
α-Amylase Assay Kit (p-Nitrophenyl Maltotriose Method)
Alias:
Amylase Test Kit,α-Amylase Detection Kit
Intended Use:
This kit is specifically designed for the in vitro quantitative determination of α-amylase activity in human serum or plasma samples. It is widely used in clinical laboratories to assess pancreatic function and diagnose related disorders.
Product Introduction

The α-Amylase Assay Kit is a highly reliable and efficient tool for measuring α-amylase activity in biological samples. It utilizes the p-nitrophenyl maltotriose method, which is known for its precision and sensitivity. The kit is essential for clinical diagnostics, particularly in evaluating pancreatic health and detecting conditions such as pancreatitis.

1. The kit features a two-reagent system that ensures accurate and reproducible results. Reagent 1 contains HEPES buffer, calcium chloride, and α-glucosidase, while Reagent 2 includes p-nitrophenyl maltotriose and HEPES buffer. This combination allows for the precise measurement of α-amylase activity.
2. The structure of the kit is designed for ease of use, with clear instructions and stable reagents that maintain their efficacy over time. The inclusion of α-glucosidase in Reagent 1 ensures that the substrate is fully hydrolyzed, leading to accurate results.
3. The primary use of this kit is in clinical laboratories for the quantitative determination of α-amylase activity in human serum or plasma. It is particularly useful in diagnosing pancreatic disorders and monitoring treatment efficacy.

The α-Amylase Assay Kit, also known as the Amylase Test Kit, is a vital tool in clinical diagnostics. Its two-reagent system, composed of HEPES buffer, calcium chloride, α-glucosidase, and p-nitrophenyl maltotriose, ensures accurate and reliable results. This kit is indispensable for assessing pancreatic function and diagnosing related conditions.

Main Features

The α-Amylase Assay Kit offers precise measurement of α-amylase activity, essential for diagnosing pancreatic disorders. Its two-reagent system ensures accuracy and reproducibility.

1. The kit provides a highly sensitive and specific method for measuring α-amylase activity, crucial for accurate clinical diagnostics.
2. It includes a stable reagent system that maintains its efficacy over time, ensuring reliable results even after prolonged storage.
3. The kit is designed for ease of use, with clear instructions and a straightforward protocol that minimizes the risk of user error.
4. It offers a wide dynamic range, allowing for the measurement of α-amylase activity across a broad spectrum of sample concentrations.
5. The kit is compatible with a variety of automated analyzers, making it suitable for high-throughput clinical laboratories.

The α-Amylase Assay Kit stands out for its precision, ease of use, and compatibility with automated systems. Its stable reagents and wide dynamic range make it an essential tool for clinical laboratories focused on pancreatic health.

Clinical Applications

The α-Amylase Assay Kit is widely used in clinical settings to diagnose and monitor pancreatic disorders, such as pancreatitis, through the measurement of α-amylase activity in serum or plasma.

1. In clinical diagnostics, the kit is used to assess pancreatic function by measuring α-amylase activity, which is a key indicator of pancreatic health.
2. It is particularly useful in the diagnosis of acute pancreatitis, where elevated α-amylase levels are a common symptom.
3. The kit is also employed in monitoring the efficacy of treatment for pancreatic disorders, providing clinicians with valuable data on patient progress.
4. In research settings, the kit is used to study the role of α-amylase in various physiological and pathological processes.
5. The kit's compatibility with automated analyzers makes it a valuable tool in high-throughput clinical laboratories, where efficiency and accuracy are paramount.

The α-Amylase Assay Kit is a cornerstone in clinical diagnostics, particularly for pancreatic disorders. Its ability to provide accurate and reliable measurements of α-amylase activity makes it indispensable in both clinical and research settings.

Purchasing Guide

When purchasing the α-Amylase Assay Kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your laboratory's needs.

1. Product specifications: Ensure the kit's sensitivity, specificity, and dynamic range align with your laboratory's requirements for α-amylase activity measurement.
2. Product types: Choose between manual and automated versions based on your laboratory's workflow and equipment capabilities.
3. Budget: Consider the cost per test and the overall budget for reagents and consumables when selecting the kit.
4. Usage scenarios: Evaluate the kit's compatibility with your laboratory's existing equipment and protocols to ensure seamless integration.

Selecting the right α-Amylase Assay Kit involves careful consideration of specifications, types, budget, and usage scenarios. Ensuring compatibility with your laboratory's needs will lead to more accurate and efficient diagnostics.

 Precautions

Proper handling and storage of the α-Amylase Assay Kit are crucial to maintain its efficacy and ensure accurate results. Follow all instructions carefully to avoid contamination and ensure reliable performance.

1. Store the kit at the recommended temperature to preserve the stability of the reagents and ensure accurate results.
2. Avoid contamination by using sterile techniques when handling samples and reagents.
3. Follow the protocol precisely to minimize variability and ensure reproducible results.
4. Regularly calibrate and maintain equipment used with the kit to ensure accurate measurements.
5. Dispose of used reagents and samples according to local regulations to prevent environmental contamination.

The α-Amylase Assay Kit requires careful handling and storage to maintain its performance. Adhering to proper protocols and precautions will ensure accurate and reliable results, making it a valuable tool in clinical diagnostics.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files