Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
α-Amylase Assay Kit (EPS-G7 Method)
The α-Amylase Assay Kit (EPS-G7 Method) is composed of two main reagents. Reagent 1 contains α-AMY Base Solution 1, which includes HEPES buffer (pH 7.10) at 100 mmol/L, glucosidase at 4.5 KU/L, magnesium sulfate at 10 mmol/L, and Krovin500 at 0.5%. Reagent 2 contains α-AMY Base Solution 2, which includes HEPES buffer (pH 7.10) at 100 mmol/L, sodium chloride at 60 mmol/L, ethylene-pNP-G7 at 5 mmol/L, and Krovin500 at 0.5%.
Product English Name:
α-Amylase Assay Kit (EPS-G7 Method)
Alias:
Amylase Test Kit,EPS-G7 Amylase Kit
Intended Use:
This kit is designed to measure the activity of α-amylase in human serum and urine samples. It is primarily used in clinical settings to assist in the diagnosis of pancreatic diseases.
Product Introduction

The α-Amylase Assay Kit (EPS-G7 Method) is a specialized diagnostic tool used to measure the activity of α-amylase in biological samples. This enzyme plays a crucial role in carbohydrate metabolism, and its levels can be indicative of various health conditions, particularly those related to the pancreas. The kit is designed for use in clinical laboratories and provides accurate and reliable results.

1. The kit features a highly sensitive and specific assay method, ensuring precise measurement of α-amylase activity. It is optimized for use with both serum and urine samples, making it versatile for different diagnostic needs.
2. The composition of the kit includes two main reagents, each formulated with specific buffers and enzymes to ensure optimal reaction conditions. The inclusion of Krovin500 enhances the stability and performance of the reagents.
3. The primary use of this kit is in the clinical diagnosis of pancreatic diseases. By measuring α-amylase activity, healthcare providers can gain valuable insights into the patient's pancreatic health and make informed decisions regarding treatment and management.

The α-Amylase Assay Kit (EPS-G7 Method) is a reliable and efficient tool for measuring α-amylase activity in clinical samples. Its well-designed composition and specific application make it an essential resource for diagnosing pancreatic diseases. Whether you're a clinician or a researcher, this kit offers the precision and reliability you need for accurate diagnostics.

Main Features

The α-Amylase Assay Kit (EPS-G7 Method) offers a range of features designed to ensure accurate and reliable measurement of α-amylase activity. Its key features include high sensitivity, specificity, and ease of use.

1. High Sensitivity: The kit is designed to detect even low levels of α-amylase activity, ensuring accurate results in a wide range of clinical samples.
2. Specificity: The assay method is highly specific to α-amylase, reducing the risk of cross-reactivity with other enzymes and ensuring precise measurements.
3. Ease of Use: The kit comes with clear instructions and is easy to set up, making it suitable for use in busy clinical laboratories.
4. Stability: The reagents are formulated to maintain stability over a long period, ensuring consistent performance even after extended storage.
5. Versatility: The kit can be used with both serum and urine samples, providing flexibility in diagnostic applications.

The α-Amylase Assay Kit (EPS-G7 Method) stands out for its high sensitivity, specificity, and ease of use. These features make it an invaluable tool for clinicians and researchers alike, ensuring accurate and reliable results in the measurement of α-amylase activity.

Clinical Applications

The α-Amylase Assay Kit (EPS-G7 Method) is widely used in clinical settings for the diagnosis and monitoring of pancreatic diseases. Its accurate measurement of α-amylase activity provides valuable insights into patient health.

1. Diagnosis of Pancreatic Diseases: The kit is primarily used to diagnose conditions such as pancreatitis, where α-amylase levels are often elevated.
2. Monitoring Treatment: It can be used to monitor the effectiveness of treatment in patients with pancreatic diseases, providing real-time feedback on patient progress.
3. Research Applications: The kit is also used in research settings to study the role of α-amylase in various metabolic processes and diseases.
4. Emergency Medicine: In emergency settings, the kit can be used to quickly assess α-amylase levels, aiding in the rapid diagnosis of acute pancreatitis.
5. Routine Health Checks: The kit can be incorporated into routine health screenings to detect early signs of pancreatic dysfunction.

The α-Amylase Assay Kit (EPS-G7 Method) is a versatile tool with a wide range of clinical applications. From diagnosing pancreatic diseases to monitoring treatment and conducting research, this kit provides reliable and accurate results that are essential for patient care.

Purchasing Guide

When purchasing the α-Amylase Assay Kit (EPS-G7 Method), it is important to consider factors such as product specifications, types, budget, and intended use to ensure you select the right product for your needs.

1. Product Specifications: Review the technical specifications of the kit, including sensitivity, specificity, and storage requirements, to ensure it meets your laboratory's standards.
2. Product Types: Consider the different types of kits available, such as those designed for specific sample types or with varying reagent formulations, to find the best fit for your application.
3. Budget: Evaluate the cost of the kit in relation to your budget, keeping in mind that higher-priced kits may offer additional features or better performance.
4. Intended Use: Determine the primary use of the kit, whether for clinical diagnostics, research, or routine health checks, to ensure it aligns with your goals.

Purchasing the α-Amylase Assay Kit (EPS-G7 Method) requires careful consideration of various factors, including product specifications, types, budget, and intended use. By taking these factors into account, you can select a kit that best meets your needs and ensures accurate and reliable results.

 Precautions

When using the α-Amylase Assay Kit (EPS-G7 Method), it is important to follow certain precautions to ensure accurate results and maintain safety in the laboratory.

1. Proper Storage: Store the kit according to the manufacturer's instructions to maintain the stability and performance of the reagents.
2. Handling: Handle the reagents with care, using appropriate personal protective equipment to avoid contamination and ensure safety.
3. Calibration: Regularly calibrate the equipment used with the kit to ensure accurate and consistent results.
4. Sample Preparation: Follow the recommended procedures for sample preparation to avoid errors that could affect the assay results.
5. Disposal: Dispose of used reagents and samples according to local regulations to minimize environmental impact and ensure safety.

Using the α-Amylase Assay Kit (EPS-G7 Method) requires attention to detail and adherence to safety protocols. By following proper storage, handling, calibration, sample preparation, and disposal procedures, you can ensure accurate results and maintain a safe laboratory environment.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files