Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
α-Amylase Assay Kit (EPS-G7 Method)
The α-Amylase Assay Kit consists of two main reagents. Reagent 1 includes a HEPES buffer (pH 7.1, 50 mmol/L), sodium chloride (NaCl, 70 mmol/L), and calcium chloride (CaCl2, 1 mmol/L). Reagent 2 contains α-glucosidase (8 KU/L) and ethylene-blocked 4-nitrophenol (EPS, 5 mmol/L). These components are designed to work together to accurately measure α-amylase activity in human serum.
Product English Name:
α-Amylase Assay Kit (EPS-G7 Method)
Alias:
Amylase Test Kit,EPS-G7 Amylase Kit
Intended Use:
This kit is specifically designed for the in vitro quantitative determination of α-amylase (α-AMY) activity in human serum. It is widely used in clinical laboratories to assess pancreatic function and diagnose related disorders.
Product Introduction

The α-Amylase Assay Kit (EPS-G7 Method) is a sophisticated diagnostic tool used to measure the activity of α-amylase in human serum. This enzyme plays a crucial role in carbohydrate metabolism, and its levels can indicate various health conditions. The kit employs a unique EPS-G7 method, ensuring high sensitivity and accuracy in detecting α-amylase activity.

1. The kit features a highly sensitive EPS-G7 method, which allows for precise measurement of α-amylase activity. This method is known for its reliability and consistency in clinical settings.
2. The composition of the kit includes two reagents: Reagent 1, which contains a HEPES buffer, sodium chloride, and calcium chloride, and Reagent 2, which includes α-glucosidase and ethylene-blocked 4-nitrophenol. These components work synergistically to ensure accurate results.
3. The primary use of this kit is to quantitatively determine α-amylase activity in human serum. This is essential for diagnosing pancreatic disorders and monitoring treatment efficacy.

The α-Amylase Assay Kit (EPS-G7 Method) is a vital tool in clinical diagnostics, offering a reliable and accurate way to measure α-amylase activity. Its unique composition and method ensure that healthcare professionals can trust the results, making it an indispensable part of modern medical practice.

Main Features

The α-Amylase Assay Kit (EPS-G7 Method) offers high sensitivity and accuracy in measuring α-amylase activity, making it a reliable choice for clinical diagnostics.

1. The kit utilizes the EPS-G7 method, which is known for its high sensitivity and precision in detecting α-amylase activity.
2. It includes two reagents that are specifically formulated to work together, ensuring consistent and reliable results.
3. The kit is designed for ease of use, with clear instructions and a straightforward protocol that can be easily followed in a clinical laboratory setting.
4. It provides quantitative results, allowing for precise measurement of α-amylase activity, which is crucial for accurate diagnosis and monitoring of pancreatic disorders.
5. The kit is compatible with a wide range of laboratory equipment, making it a versatile choice for various clinical settings.

The α-Amylase Assay Kit (EPS-G7 Method) stands out for its precision, ease of use, and compatibility with standard laboratory equipment. Its ability to provide accurate quantitative results makes it an essential tool for diagnosing and monitoring pancreatic disorders.

Clinical Applications

The α-Amylase Assay Kit (EPS-G7 Method) is widely used in clinical settings to diagnose and monitor pancreatic disorders by measuring α-amylase activity in human serum.

1. The kit is used in the diagnosis of acute pancreatitis, where elevated levels of α-amylase are a key indicator.
2. It is also employed in monitoring the progression of chronic pancreatitis, helping clinicians assess the effectiveness of treatment.
3. The kit is useful in diagnosing other conditions that affect α-amylase levels, such as salivary gland disorders and certain types of cancer.
4. It is used in research settings to study the role of α-amylase in various metabolic processes and diseases.
5. The kit is also utilized in routine health check-ups to screen for potential pancreatic issues in asymptomatic individuals.

The α-Amylase Assay Kit (EPS-G7 Method) is a versatile tool in clinical diagnostics, offering valuable insights into pancreatic health and aiding in the diagnosis and monitoring of various disorders. Its application extends beyond routine diagnostics, making it a valuable asset in both clinical and research settings.

Purchasing Guide

When purchasing the α-Amylase Assay Kit (EPS-G7 Method), it is important to consider product specifications, types, budget, and intended use to ensure it meets your laboratory's needs.

1. Product Parameters: Ensure the kit's sensitivity, accuracy, and compatibility with your laboratory equipment align with your diagnostic requirements.
2. Product Types: Consider whether you need a standard kit or a specialized version for specific applications, such as high-throughput screening or research purposes.
3. Budget: Evaluate the cost-effectiveness of the kit, taking into account the number of tests it can perform and the overall value it provides.
4. Usage Scenarios: Assess the kit's suitability for your laboratory's workflow, including ease of use, storage requirements, and the availability of technical support.

Choosing the right α-Amylase Assay Kit (EPS-G7 Method) involves careful consideration of various factors, including product specifications, types, budget, and intended use. By taking these into account, you can ensure that the kit meets your laboratory's needs and provides reliable results.

 Precautions

Proper handling and storage of the α-Amylase Assay Kit (EPS-G7 Method) are crucial to ensure accurate results and maintain the integrity of the reagents.

1. Storage: Store the kit at the recommended temperature to prevent degradation of the reagents. Avoid exposure to extreme temperatures or direct sunlight.
2. Handling: Use aseptic techniques when handling the reagents to prevent contamination. Ensure all equipment used is clean and properly calibrated.
3. Expiration: Always check the expiration date before use. Do not use expired reagents as they may yield inaccurate results.
4. Disposal: Dispose of used reagents and materials according to local regulations and laboratory protocols to ensure safety and environmental compliance.
5. Training: Ensure that all personnel using the kit are properly trained in its use and understand the importance of following the protocol precisely.

Taking the necessary precautions when using the α-Amylase Assay Kit (EPS-G7 Method) is essential for obtaining reliable results. Proper storage, handling, and disposal, along with adequate training, will help maintain the kit's effectiveness and ensure the safety of laboratory personnel.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files