Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
α-Amylase (α-AMY) Assay Kit (EPS Substrate Method)
The kit consists of two main reagents. Reagent 1 contains Good’s buffer (100mmol/L), sodium chloride (50mmol/L), magnesium chloride (10mmol/L), and α-glucosidase (≥2kU/L). Reagent 2 includes Good’s buffer (100mmol/L) and 4,6-ethylidene-4-nitrophenyl-α-heptoside (1.6mmol/L). These components are designed to work together to measure α-amylase activity accurately.
Product English Name:
α-Amylase (α-AMY) Assay Kit (EPS Substrate Method)
Alias:
EPS Method α-Amylase Kit,α-AMY Test Kit
Intended Use:
This kit is used for the in vitro quantitative determination of α-amylase (α-AMY) activity in human serum, plasma, or urine. It is essential for diagnosing and monitoring conditions related to pancreatic and salivary gland function.
Product Introduction

The α-Amylase (α-AMY) Assay Kit (EPS Substrate Method) is a highly reliable and efficient tool for measuring α-amylase activity in biological samples. It is widely used in clinical laboratories for its precision and ease of use. The kit employs a colorimetric method to detect enzyme activity, providing accurate and reproducible results.

1. The kit features a unique EPS substrate method, which ensures high sensitivity and specificity in detecting α-amylase activity. This method is less prone to interference from other enzymes, making it ideal for clinical diagnostics.
2. The composition of the kit includes two reagents that work synergistically. Reagent 1 contains essential buffers and enzymes, while Reagent 2 provides the substrate necessary for the enzymatic reaction. This combination ensures optimal performance and reliability.
3. The primary use of this kit is to measure α-amylase activity in human serum, plasma, or urine. It is particularly useful in diagnosing pancreatic disorders, salivary gland diseases, and other conditions where α-amylase levels are indicative of health status.

The α-Amylase (α-AMY) Assay Kit (EPS Substrate Method) is a robust and reliable tool for clinical diagnostics. Its unique EPS substrate method and well-balanced reagent composition make it a preferred choice for measuring α-amylase activity. Whether you're diagnosing pancreatic disorders or monitoring salivary gland function, this kit delivers consistent and accurate results.

Main Features

The α-Amylase (α-AMY) Assay Kit offers high sensitivity, specificity, and ease of use, making it a top choice for clinical laboratories.

1. High Sensitivity: The EPS substrate method ensures that even low levels of α-amylase activity can be detected with precision.
2. Specificity: The kit is designed to minimize interference from other enzymes, ensuring accurate results.
3. Ease of Use: The kit comes with clear instructions and requires minimal preparation, making it user-friendly.
4. Reproducibility: The consistent performance of the kit ensures that results are reliable and reproducible across different batches.
5. Wide Application: Suitable for use with serum, plasma, and urine samples, the kit is versatile and adaptable to various clinical settings.

The α-Amylase (α-AMY) Assay Kit stands out for its high sensitivity, specificity, and ease of use. Its ability to deliver reproducible results across different samples makes it an indispensable tool in clinical diagnostics. Whether you're working in a small lab or a large hospital, this kit will meet your needs with reliability and precision.

Clinical Applications

This kit is widely used in clinical settings for diagnosing and monitoring conditions related to α-amylase activity, such as pancreatic and salivary gland disorders.

1. Pancreatic Disorders: The kit is essential for diagnosing acute and chronic pancreatitis, where α-amylase levels are significantly elevated.
2. Salivary Gland Diseases: It is also used to detect salivary gland disorders, such as sialadenitis, where α-amylase activity may be altered.
3. Monitoring Treatment: The kit is useful for monitoring the effectiveness of treatment in patients with pancreatic or salivary gland diseases.
4. Research Applications: Beyond clinical diagnostics, the kit is also used in research settings to study α-amylase activity in various biological samples.
5. Routine Screening: It is often included in routine health check-ups to screen for early signs of pancreatic or salivary gland dysfunction.

The α-Amylase (α-AMY) Assay Kit is a versatile tool in clinical diagnostics, essential for diagnosing and monitoring pancreatic and salivary gland disorders. Its applications extend to research and routine screening, making it a valuable asset in both clinical and laboratory settings.

Purchasing Guide

When purchasing the α-Amylase (α-AMY) Assay Kit, consider product specifications, types, budget, and intended use to ensure you select the right kit for your needs.

1. Product Specifications: Review the kit's sensitivity, specificity, and compatibility with your laboratory equipment.
2. Product Types: Choose between different kit formats, such as single-use or bulk packs, based on your laboratory's volume and needs.
3. Budget: Consider the cost per test and overall budget to ensure the kit is cost-effective for your laboratory.
4. Intended Use: Ensure the kit is suitable for your specific applications, whether for clinical diagnostics, research, or routine screening.

Selecting the right α-Amylase (α-AMY) Assay Kit involves careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can ensure that the kit meets your laboratory's needs and delivers reliable results.

 Precautions

Proper handling and storage of the α-Amylase (α-AMY) Assay Kit are crucial to ensure accurate results and prolong the kit's shelf life.

1. Storage Conditions: Store the kit at the recommended temperature to maintain reagent stability and performance.
2. Handling: Follow proper laboratory protocols when handling reagents to avoid contamination and ensure accurate results.
3. Expiration Date: Always check the expiration date before use to ensure the reagents are still effective.
4. Calibration: Regularly calibrate your equipment to ensure the accuracy of the results obtained with the kit.
5. Disposal: Dispose of used reagents and materials according to local regulations to ensure safety and environmental compliance.

To get the most out of your α-Amylase (α-AMY) Assay Kit, it's essential to follow proper storage, handling, and disposal procedures. By adhering to these precautions, you can ensure the kit's performance and longevity, ultimately leading to reliable and accurate results in your clinical diagnostics.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files