Alpha-1 Antitrypsin Detection Kit (Immunoturbidimetric Method)
The Alpha-1 Antitrypsin Detection Kit is composed of two main reagents: R1 and R2. R1 contains Tris buffer (pH 8.3), polyethylene glycol 6000, and sodium azide. R2 includes goat anti-human α1-AT antiserum and sodium azide. These components work together to ensure accurate and reliable detection of α1-antitrypsin levels in human serum.
Product English Name:
Alpha-1 Antitrypsin Detection Kit (Immunoturbidimetric Method)
Alias:
A1AT Test Kit,Alpha-1 Antitrypsin Assay Kit
Intended Use:
This kit is designed for the in vitro quantitative detection of α1-antitrypsin (α1-AT) levels in human serum. It is widely used in clinical laboratories to assist in the diagnosis and monitoring of conditions related to α1-antitrypsin deficiency, such as liver disease and chronic obstructive pulmonary disease (COPD).
Product Introduction

The Alpha-1 Antitrypsin Detection Kit is a sophisticated diagnostic tool used to measure the concentration of α1-antitrypsin in human serum. This protein plays a crucial role in protecting tissues from enzymes released by inflammatory cells. The kit employs an immunoturbidimetric method, ensuring high sensitivity and specificity. It is an essential tool for clinicians and researchers studying α1-antitrypsin-related disorders.

1. The kit is characterized by its high precision and reliability, making it a trusted choice for clinical diagnostics. It utilizes advanced immunoturbidimetric technology to ensure accurate results.
2. The kit consists of two main reagents: R1 and R2. R1 contains Tris buffer, polyethylene glycol 6000, and sodium azide, while R2 includes goat anti-human α1-AT antiserum and sodium azide. These components are carefully formulated to optimize the detection process.
3. The primary use of this kit is to quantitatively detect α1-antitrypsin levels in human serum. It is particularly useful in diagnosing and monitoring conditions such as α1-antitrypsin deficiency, liver disease, and COPD.

The Alpha-1 Antitrypsin Detection Kit, also known as the A1AT Test Kit, is a vital tool in clinical diagnostics. Its precise and reliable detection capabilities make it indispensable for healthcare professionals. The kit's carefully formulated components ensure accurate results, aiding in the diagnosis and management of α1-antitrypsin-related conditions.

Main Features

The Alpha-1 Antitrypsin Detection Kit offers high sensitivity and specificity in detecting α1-antitrypsin levels. Its immunoturbidimetric method ensures reliable results, making it a preferred choice for clinical laboratories.

1. High Sensitivity: The kit is designed to detect even low levels of α1-antitrypsin, ensuring accurate diagnosis of deficiency-related conditions.
2. Specificity: The use of goat anti-human α1-AT antiserum ensures that the kit specifically targets α1-antitrypsin, reducing the risk of cross-reactivity.
3. Ease of Use: The kit is user-friendly, with clear instructions and straightforward procedures, making it accessible to laboratory technicians.
4. Stability: The reagents are stable under recommended storage conditions, ensuring consistent performance over time.
5. Comprehensive Results: The kit provides quantitative results, allowing for precise monitoring of α1-antitrypsin levels in patients.

The Alpha-1 Antitrypsin Detection Kit stands out for its high sensitivity, specificity, and ease of use. Its stable reagents and comprehensive results make it an essential tool for clinical diagnostics, particularly in the management of α1-antitrypsin-related disorders.

Clinical Applications

The Alpha-1 Antitrypsin Detection Kit is widely used in clinical settings to diagnose and monitor α1-antitrypsin deficiency and related conditions such as liver disease and COPD.

1. Diagnosis of α1-Antitrypsin Deficiency: The kit is crucial for identifying individuals with α1-antitrypsin deficiency, a condition that can lead to severe liver and lung disease.
2. Monitoring Disease Progression: Clinicians use the kit to monitor α1-antitrypsin levels in patients with chronic conditions, helping to assess disease progression and response to treatment.
3. Research Applications: The kit is also used in research settings to study the role of α1-antitrypsin in various diseases and to develop new therapeutic strategies.
4. Screening Programs: The kit is employed in screening programs to identify individuals at risk of α1-antitrypsin deficiency, enabling early intervention and management.
5. Quality Control: Clinical laboratories use the kit as part of their quality control processes to ensure accurate and reliable test results.

The Alpha-1 Antitrypsin Detection Kit is a versatile tool in clinical practice, essential for diagnosing and monitoring α1-antitrypsin deficiency and related conditions. Its applications extend to research and quality control, making it a valuable asset in healthcare and scientific studies.

Purchasing Guide

When purchasing the Alpha-1 Antitrypsin Detection Kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your laboratory's needs.

1. Product Specifications: Review the kit's specifications, including sensitivity, specificity, and storage requirements, to ensure it aligns with your laboratory's standards.
2. Product Types: Choose the appropriate kit type based on your laboratory's volume and testing frequency. Some kits are designed for high-throughput labs, while others are suitable for smaller facilities.
3. Budget Considerations: Evaluate the cost of the kit in relation to your laboratory's budget. Consider the long-term value and reliability of the product.
4. Intended Use: Ensure the kit is suitable for your specific applications, whether for clinical diagnostics, research, or quality control purposes.

Purchasing the Alpha-1 Antitrypsin Detection Kit requires careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can select a kit that meets your laboratory's needs and ensures accurate and reliable results.

 Precautions

Proper handling and storage of the Alpha-1 Antitrypsin Detection Kit are essential to ensure accurate results and maintain the integrity of the reagents.

1. Storage Conditions: Store the kit at the recommended temperature to maintain reagent stability. Avoid exposure to extreme temperatures or direct sunlight.
2. Handling Precautions: Use aseptic techniques when handling the reagents to prevent contamination. Follow the manufacturer's instructions for proper use.
3. Expiration Date: Always check the expiration date before using the kit. Do not use expired reagents, as they may yield inaccurate results.
4. Disposal: Dispose of used reagents and materials according to local regulations and laboratory safety protocols.
5. Training: Ensure that laboratory personnel are properly trained in the use of the kit to avoid errors and ensure consistent results.

The Alpha-1 Antitrypsin Detection Kit requires careful handling and storage to ensure accurate and reliable results. By following proper precautions, laboratory personnel can maintain the integrity of the reagents and achieve consistent performance in clinical diagnostics.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files