The Factor VIII (FVIII) Assay Kit (Coagulation Method) STA®–DEFICIENT VIII is a specialized diagnostic tool used to quantify Factor VIII levels in human plasma. It is essential for diagnosing hemophilia A and monitoring treatment efficacy. The kit includes lyophilized plasma with Factor VIII removed, ensuring accurate and reliable results.
1. The kit is characterized by its high precision and sensitivity, making it suitable for clinical laboratories. It uses a coagulation method to ensure accurate measurement of Factor VIII levels.
2. The composition includes lyophilized anticoagulated human plasma with Factor VIII selectively removed by immunoadsorption. This ensures that the plasma is free from Factor VIII, providing a reliable baseline for testing.
3. The primary use of this kit is to measure Factor VIII levels in plasma, which is crucial for diagnosing hemophilia A and other coagulation disorders. It is also used in monitoring the effectiveness of treatment in patients with these conditions.
The Factor VIII (FVIII) Assay Kit (Coagulation Method) STA®–DEFICIENT VIII is a vital tool in the diagnosis and management of hemophilia A. Its precision and reliability make it a trusted choice for clinical laboratories. The kit's unique composition ensures accurate results, making it indispensable in the field of coagulation diagnostics.
The main features of the Factor VIII Assay Kit include high precision, sensitivity, and reliability in measuring Factor VIII levels in plasma.
1. High precision: The kit uses a coagulation method that ensures accurate measurement of Factor VIII levels, reducing the risk of errors.
2. Sensitivity: The kit is highly sensitive, capable of detecting even low levels of Factor VIII in plasma, which is crucial for early diagnosis.
3. Reliability: The lyophilized plasma with Factor VIII removed provides a consistent and reliable baseline for testing.
4. Ease of use: The kit is designed for ease of use in clinical laboratories, with clear instructions and barcode labels for efficient tracking.
5. Versatility: The kit can be used for both diagnostic purposes and monitoring treatment efficacy in patients with hemophilia A.
The Factor VIII Assay Kit stands out for its precision, sensitivity, and reliability. Its ease of use and versatility make it a valuable tool in clinical laboratories, ensuring accurate diagnosis and effective monitoring of hemophilia A.
The Factor VIII Assay Kit is widely used in clinical settings for diagnosing hemophilia A and monitoring treatment efficacy.
1. Diagnosis of hemophilia A: The kit is used to measure Factor VIII levels in plasma, which is essential for diagnosing hemophilia A.
2. Monitoring treatment: It is used to monitor the effectiveness of treatment in patients with hemophilia A, ensuring that Factor VIII levels are within the desired range.
3. Research applications: The kit is also used in research settings to study coagulation disorders and develop new treatments.
4. Quality control: Clinical laboratories use the kit for quality control purposes, ensuring that their testing methods are accurate and reliable.
5. Patient management: The kit aids in the management of patients with hemophilia A, providing crucial data for treatment decisions.
The Factor VIII Assay Kit is indispensable in clinical settings, providing accurate data for the diagnosis and management of hemophilia A. Its applications extend to research and quality control, making it a versatile tool in the field of coagulation diagnostics.
The purchasing guide for the Factor VIII Assay Kit includes considerations for product parameters, types, budget, and usage scenarios.
1. Product parameters: When purchasing the kit, consider the sensitivity, precision, and reliability of the product to ensure it meets your laboratory's needs.
2. Product types: There are different types of Factor VIII Assay Kits available, so choose one that aligns with your specific diagnostic requirements.
3. Budget: Consider your budget when purchasing the kit, as prices may vary depending on the supplier and the quantity ordered.
4. Usage scenarios: Evaluate the intended use of the kit, whether for diagnostic purposes, research, or quality control, to ensure it is suitable for your needs.
Purchasing the Factor VIII Assay Kit requires careful consideration of product parameters, types, budget, and usage scenarios. Ensuring that the kit meets your laboratory's needs will guarantee accurate and reliable results.
When using the Factor VIII Assay Kit, it is important to follow the instructions carefully to ensure accurate results and avoid potential risks.
1. Proper storage: Store the kit at the recommended temperature to maintain the integrity of the lyophilized plasma and other components.
2. Handling: Handle the kit components with care to avoid contamination, which could affect the accuracy of the results.
3. Calibration: Ensure that the coagulation analyzer is properly calibrated before using the kit to measure Factor VIII levels.
4. Disposal: Follow proper disposal procedures for used kit components to prevent environmental contamination.
5. Training: Ensure that laboratory personnel are properly trained in using the kit to avoid errors and ensure accurate results.
Using the Factor VIII Assay Kit requires attention to proper storage, handling, calibration, disposal, and training. Following these precautions will ensure accurate results and maintain the integrity of the testing process.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.