25-Hydroxy Vitamin D Assay Kit (Cloned Enzyme Donor Immunoassay)
The 25-Hydroxy Vitamin D Assay Kit is composed of several key components: a diluent containing phosphate sodium, potassium chloride, sodium chloride, sodium azide, and vitamin D monoclonal antibody; Reagent 1 (R1) with acetic acid, NPG substrate, and Tween 20; Reagent 2 (R2) with phosphate sodium and sodium azide; Reagent 3 (R3) containing Tris-HCL, sodium chloride, glycerol, sodium azide, and enzyme acceptor. Additionally, a calibration solution with a specific quantity of 25-OH Vitamin D in human serum is optionally provided.
Product English Name:
25-Hydroxy Vitamin D Assay Kit (Cloned Enzyme Donor Immunoassay)
Alias:
25-OH Vitamin D Test Kit,CEDIA Vitamin D Kit
Intended Use:
This kit is designed for the in vitro quantitative determination of 25-hydroxyvitamin D (25-OH VD) levels in human serum. It is widely used in clinical laboratories to assess vitamin D status, which is crucial for diagnosing and managing conditions related to vitamin D deficiency or excess.
Product Introduction

The 25-Hydroxy Vitamin D Assay Kit is a sophisticated diagnostic tool used to measure the concentration of 25-hydroxyvitamin D in human serum. This kit employs the Cloned Enzyme Donor Immunoassay (CEDIA) technology, which offers high sensitivity and specificity. It is essential for evaluating vitamin D levels, which play a critical role in bone health, immune function, and overall well-being.

1. The kit features a highly sensitive and specific immunoassay method, ensuring accurate detection of 25-hydroxyvitamin D levels. The use of monoclonal antibodies enhances the precision of the assay.
2. The composition includes a diluent, three reagents, and an optional calibration solution. Each component is carefully formulated to ensure stability and reliability during the assay process.
3. The primary use of this kit is to quantitatively measure 25-hydroxyvitamin D in human serum, aiding in the diagnosis and management of vitamin D-related disorders.

The 25-Hydroxy Vitamin D Assay Kit, also known as the CEDIA Vitamin D Kit, is a vital tool in clinical diagnostics. Its precise measurement capabilities and robust composition make it indispensable for assessing vitamin D levels, which are crucial for maintaining optimal health.

Main Features

The 25-Hydroxy Vitamin D Assay Kit offers high sensitivity and specificity, utilizing CEDIA technology for accurate detection of vitamin D levels. It is designed for ease of use and reliability in clinical settings.

1. High Sensitivity: The kit can detect low levels of 25-hydroxyvitamin D, making it suitable for diagnosing vitamin D deficiency.
2. Specificity: The use of monoclonal antibodies ensures that the assay specifically targets 25-hydroxyvitamin D, reducing the risk of cross-reactivity.
3. Stability: The reagents are formulated to maintain stability over a wide range of storage conditions, ensuring consistent performance.
4. Ease of Use: The kit is designed for straightforward operation, with clear instructions and minimal preparation required.
5. Reliability: The inclusion of a calibration solution allows for accurate standardization, enhancing the reliability of the results.

The 25-Hydroxy Vitamin D Assay Kit stands out for its high sensitivity, specificity, and reliability. Its user-friendly design and robust performance make it a preferred choice for clinical laboratories.

Clinical Applications

The 25-Hydroxy Vitamin D Assay Kit is widely used in clinical laboratories to assess vitamin D status, which is crucial for diagnosing and managing conditions related to vitamin D deficiency or excess.

1. Diagnosis of Vitamin D Deficiency: The kit is used to identify individuals with low levels of 25-hydroxyvitamin D, which can lead to conditions such as rickets and osteoporosis.
2. Monitoring Vitamin D Therapy: It helps in tracking the effectiveness of vitamin D supplementation in patients with deficiency.
3. Research Applications: The kit is also used in clinical research to study the role of vitamin D in various diseases.
4. Public Health Screening: It is employed in large-scale screening programs to assess the vitamin D status of populations.
5. Personalized Medicine: The kit aids in tailoring vitamin D supplementation based on individual needs, promoting personalized healthcare.

The 25-Hydroxy Vitamin D Assay Kit is a versatile tool in clinical practice, essential for diagnosing, monitoring, and researching vitamin D-related conditions. Its applications extend from individual patient care to public health initiatives.

Purchasing Guide

When purchasing the 25-Hydroxy Vitamin D Assay Kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your laboratory's needs.

1. Product Specifications: Evaluate the kit's sensitivity, specificity, and stability to ensure it aligns with your laboratory's requirements.
2. Product Types: Choose between different kit formats, such as manual or automated, based on your laboratory's workflow.
3. Budget: Consider the cost of the kit, including any additional reagents or calibration solutions, to stay within your budget.
4. Intended Use: Ensure the kit is suitable for your specific applications, whether for routine diagnostics, research, or large-scale screening.

Selecting the right 25-Hydroxy Vitamin D Assay Kit involves careful consideration of specifications, types, budget, and intended use. Making an informed choice ensures optimal performance and value for your laboratory.

 Precautions

Proper handling and storage of the 25-Hydroxy Vitamin D Assay Kit are essential to maintain its performance and ensure accurate results.

1. Storage Conditions: Store the kit at the recommended temperature to preserve the stability of the reagents.
2. Handling: Follow the manufacturer's instructions for handling the reagents to avoid contamination or degradation.
3. Calibration: Regularly calibrate the assay using the provided calibration solution to ensure accuracy.
4. Safety: Use appropriate personal protective equipment when handling the reagents to prevent exposure to hazardous chemicals.
5. Disposal: Dispose of used reagents and materials according to local regulations to minimize environmental impact.

Adhering to proper storage, handling, and safety precautions is crucial for the optimal performance of the 25-Hydroxy Vitamin D Assay Kit. Following these guidelines ensures reliable results and protects both the user and the environment.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files