The 25-Hydroxy Vitamin D Assay Kit (Fluorescence Immunochromatography) is a state-of-the-art diagnostic tool designed for the accurate and rapid quantification of 25-hydroxy vitamin D levels in biological samples. This kit employs advanced fluorescence immunochromatography technology, ensuring high sensitivity and specificity. It is an essential tool for healthcare professionals to evaluate vitamin D deficiency or excess, which can have significant implications for patient health.
1. Features: The kit offers high sensitivity and specificity due to its advanced fluorescence immunochromatography technology. It provides rapid results, typically within 15 minutes, making it suitable for both clinical and research settings. The kit is easy to use, requiring minimal sample preparation, and is compatible with various sample types, including serum, plasma, and whole blood.
2. Composition: The kit includes test cards, diluent, and calibration information cards. The test card is composed of a nitrocellulose membrane with T-line and C-line, a conjugate pad with fluorescein-labeled antibodies, absorbent paper, and a backing card. The diluent is a phosphate buffer solution, and the calibration information card contains essential calibration data.
3. Use: This kit is primarily used for the quantitative detection of 25-hydroxy vitamin D in serum, plasma, or whole blood samples. It is widely utilized in clinical laboratories to assess vitamin D status, which is critical for diagnosing and managing conditions related to vitamin D deficiency or excess.
The 25-Hydroxy Vitamin D Assay Kit is a reliable and efficient tool for measuring vitamin D levels. Its advanced technology ensures accurate results, while its user-friendly design makes it accessible for various healthcare settings. Whether you're a clinician or a researcher, this kit provides the precision and speed needed for effective vitamin D assessment.
The main features of the 25-Hydroxy Vitamin D Assay Kit include high sensitivity, rapid results, and ease of use. It is designed for accurate quantification of vitamin D levels in various biological samples.
1. High Sensitivity: The kit utilizes fluorescence immunochromatography, which provides high sensitivity in detecting 25-hydroxy vitamin D levels, even at low concentrations.
2. Rapid Results: Results are typically available within 15 minutes, making it ideal for clinical settings where quick decision-making is crucial.
3. Ease of Use: The kit requires minimal sample preparation and is straightforward to operate, reducing the likelihood of user error.
4. Compatibility: It is compatible with serum, plasma, and whole blood samples, offering flexibility in sample collection and processing.
5. Calibration: The kit includes a calibration information card that ensures accurate and traceable results, adhering to national standards.
The 25-Hydroxy Vitamin D Assay Kit stands out for its high sensitivity, rapid results, and user-friendly design. These features make it an indispensable tool for healthcare professionals aiming to accurately assess vitamin D levels in patients.
The 25-Hydroxy Vitamin D Assay Kit is widely used in clinical settings to assess vitamin D status, which is crucial for diagnosing and managing conditions related to vitamin D deficiency or excess.
1. Diagnosis of Vitamin D Deficiency: The kit is used to diagnose vitamin D deficiency, which can lead to conditions such as rickets in children and osteomalacia in adults.
2. Monitoring Vitamin D Therapy: It is employed to monitor the effectiveness of vitamin D supplementation in patients with diagnosed deficiencies.
3. Research Applications: The kit is also used in research settings to study the role of vitamin D in various health conditions, including immune function and chronic diseases.
4. Public Health Screening: It is utilized in public health programs to screen populations at risk of vitamin D deficiency, such as the elderly or those with limited sun exposure.
5. Clinical Trials: The kit is used in clinical trials to assess the impact of vitamin D on various health outcomes, providing valuable data for medical research.
The 25-Hydroxy Vitamin D Assay Kit is a versatile tool in clinical practice, essential for diagnosing and managing vitamin D-related conditions. Its applications extend from patient care to research, making it a valuable asset in the medical field.
When purchasing the 25-Hydroxy Vitamin D Assay Kit, consider product parameters, types, budget, and usage scenarios to ensure it meets your specific needs.
1. Product Parameters: Evaluate the kit's sensitivity, specificity, and compatibility with different sample types to ensure it meets your laboratory's requirements.
2. Product Types: Choose between different kit formats, such as single-use or multi-use, based on your laboratory's volume and workflow.
3. Budget: Consider the cost per test and the overall budget for your laboratory to ensure the kit is cost-effective.
4. Usage Scenarios: Assess the kit's suitability for your specific clinical or research applications, ensuring it aligns with your operational needs.
Purchasing the 25-Hydroxy Vitamin D Assay Kit requires careful consideration of various factors, including product parameters, types, budget, and usage scenarios. By evaluating these aspects, you can ensure the kit meets your laboratory's specific needs and provides reliable results.
Proper handling and storage of the 25-Hydroxy Vitamin D Assay Kit are essential to ensure accurate results and maintain the integrity of the components.
1. Storage Conditions: Store the kit at the recommended temperature to prevent degradation of the components, ensuring the accuracy of the results.
2. Handling: Follow the manufacturer's instructions for handling the kit to avoid contamination or damage to the components.
3. Calibration: Ensure that the calibration information card is used correctly and that test cards from different batches are not mixed.
4. Sample Preparation: Properly prepare samples according to the kit's instructions to avoid errors in the assay results.
5. Disposal: Dispose of used components according to local regulations to ensure safety and environmental compliance.
Adhering to the proper handling, storage, and disposal guidelines for the 25-Hydroxy Vitamin D Assay Kit is crucial for obtaining accurate results and maintaining the kit's integrity. By following these precautions, you can ensure the reliability of your vitamin D assessments.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.