25-Hydroxy Vitamin D Assay Kit (Latex Immunoturbidimetric Method)
The kit consists of Reagent 1: Phosphate buffer (pH 7.2) 50mmol/L, Reagent 2: 25-Hydroxy Vitamin D antibody-bound latex, Calibrators: HEPES buffer (pH 7.0), human serum (≥5%), 25-Hydroxy Vitamin D with target concentrations at levels 1: 0ng/mL, 2: 15-35ng/mL, 3: 45-70ng/mL, 4: 85-115ng/mL, 5: 135-165ng/mL. Controls: HEPES buffer (pH 7.0), human serum (≥5%), 25-Hydroxy Vitamin D with control target ranges at levels 1: 20-30ng/mL, 2: 40-60ng/mL. Calibrators and controls are batch-specific, with specific concentrations indicated on the bottle labels.
Product English Name:
25-Hydroxy Vitamin D Assay Kit (Latex Immunoturbidimetric Method)
Alias:
Vitamin D Test Kit,25-OH-VD Assay Kit
Intended Use:
This kit is used for the quantitative in vitro determination of 25-Hydroxy Vitamin D (25-OH-VD) in human serum. It is primarily used in clinical settings for the auxiliary diagnosis of diseases related to Vitamin D deficiency.
Product Introduction

The 25-Hydroxy Vitamin D Assay Kit is a sophisticated diagnostic tool designed to measure the levels of 25-OH-VD in human serum accurately. Utilizing the latex immunoturbidimetric method, this kit offers a reliable and efficient means of assessing Vitamin D status, which is crucial for diagnosing and managing Vitamin D deficiency-related conditions.

1. The kit features a high sensitivity and specificity, ensuring accurate detection of 25-OH-VD levels. It employs a latex immunoturbidimetric method, which is known for its precision and reliability in clinical diagnostics.
2. The composition includes a phosphate buffer, 25-Hydroxy Vitamin D antibody-bound latex, and a series of calibrators and controls. These components are meticulously formulated to ensure consistent and reproducible results.
3. The primary use of this kit is in clinical laboratories for the quantitative assessment of 25-OH-VD in human serum. It aids in the diagnosis and management of Vitamin D deficiency, which is linked to various health conditions such as osteoporosis, rickets, and certain autoimmune diseases.

The 25-Hydroxy Vitamin D Assay Kit, also known as the Vitamin D Test Kit, is an essential tool in modern clinical diagnostics. Its high sensitivity and specificity, combined with a robust composition, make it a reliable choice for assessing Vitamin D status. This kit plays a pivotal role in the diagnosis and management of Vitamin D deficiency-related diseases, ensuring that patients receive timely and accurate care.

Main Features

The main features of the 25-Hydroxy Vitamin D Assay Kit include high sensitivity, specificity, and reliability in detecting 25-OH-VD levels in human serum. It is designed for ease of use in clinical laboratories.

1. High Sensitivity: The kit can detect low levels of 25-OH-VD, making it suitable for early diagnosis of Vitamin D deficiency.
2. Specificity: The antibody-bound latex ensures that only 25-OH-VD is detected, minimizing cross-reactivity with other substances.
3. Reliability: The kit provides consistent and reproducible results, essential for clinical decision-making.
4. Ease of Use: Designed for clinical laboratories, the kit is straightforward to use, with clear instructions and minimal preparation required.
5. Comprehensive Calibration: The kit includes multiple calibrators and controls, ensuring accurate quantification across a wide range of 25-OH-VD concentrations.

The 25-Hydroxy Vitamin D Assay Kit stands out for its high sensitivity, specificity, and reliability. Its ease of use and comprehensive calibration make it an indispensable tool in clinical laboratories, ensuring accurate and timely diagnosis of Vitamin D deficiency.

Clinical Applications

The 25-Hydroxy Vitamin D Assay Kit is widely used in clinical settings for the diagnosis and management of Vitamin D deficiency-related diseases. It is particularly valuable in assessing bone health and immune function.

1. Diagnosis of Vitamin D Deficiency: The kit is used to measure 25-OH-VD levels, aiding in the diagnosis of conditions such as osteoporosis and rickets.
2. Monitoring Treatment: It helps in monitoring the effectiveness of Vitamin D supplementation in patients with deficiency.
3. Research Applications: The kit is also used in clinical research to study the role of Vitamin D in various diseases.
4. Public Health Screening: It is employed in large-scale screening programs to assess Vitamin D status in populations.
5. Pediatric Care: The kit is used in pediatric settings to diagnose and manage Vitamin D deficiency in children.

The 25-Hydroxy Vitamin D Assay Kit is a versatile tool in clinical practice, used for diagnosing and managing Vitamin D deficiency-related diseases. Its applications extend from individual patient care to large-scale public health screening, making it a valuable asset in modern healthcare.

Purchasing Guide

When purchasing the 25-Hydroxy Vitamin D Assay Kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your clinical laboratory needs.

1. Product Specifications: Review the kit's sensitivity, specificity, and range of detection to ensure it aligns with your diagnostic requirements.
2. Product Types: Choose between different kit formats, such as single-use or multi-use, based on your laboratory's workflow and volume of tests.
3. Budget: Consider the cost of the kit, including any additional reagents or equipment required, to ensure it fits within your budget.
4. Usage Scenarios: Evaluate the kit's suitability for your specific clinical applications, such as routine diagnostics or research purposes.

Purchasing the 25-Hydroxy Vitamin D Assay Kit requires careful consideration of product specifications, types, budget, and usage scenarios. By aligning these factors with your clinical laboratory's needs, you can ensure that the kit will effectively support your diagnostic and research activities.

 Precautions

Proper handling and storage of the 25-Hydroxy Vitamin D Assay Kit are essential to ensure accurate results and maintain the integrity of the reagents.

1. Storage Conditions: Store the kit at the recommended temperature to prevent degradation of the reagents.
2. Handling: Follow the manufacturer's instructions for handling the reagents to avoid contamination and ensure accurate results.
3. Calibration: Regularly calibrate the kit using the provided calibrators to maintain accuracy.
4. Quality Control: Use the included controls to monitor the performance of the kit and ensure consistent results.
5. Disposal: Dispose of used reagents and materials according to local regulations to prevent environmental contamination.

The 25-Hydroxy Vitamin D Assay Kit requires careful handling and storage to ensure accurate and reliable results. By adhering to the recommended precautions, you can maintain the integrity of the reagents and support effective clinical diagnostics.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files