Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
25-Hydroxy Vitamin D Detection Kit (Quantum Dot Fluorescence Immunoassay)
The kit includes detection cards, aluminum foil bags, desiccants, test strips, and plastic cards. Each test strip consists of absorbent paper, nitrocellulose membrane, sample pad, quantum dot-labeled pad, and PVC backing. The nitrocellulose membrane has a T-line (test line) coated with 1 mg/mL mouse anti-human 25-hydroxy vitamin D monoclonal antibody and a C-line (control line) coated with 0.5 mg/mL internal control antibody (mouse-derived). The labeled pad contains 0.3 mg/mL 25-hydroxy vitamin D hapten quantum dot conjugate (E. coli). The kit is available in 20 or 50 test formats.
Product English Name:
25-Hydroxy Vitamin D Detection Kit (Quantum Dot Fluorescence Immunoassay)
Alias:
25-OH-VD Test Kit,Vitamin D Assay Kit
Intended Use:
This kit is designed for the quantitative detection of 25-hydroxy vitamin D (25-OH-VD) in human serum, plasma, and whole blood. It is used in clinical settings to assess vitamin D levels, which are crucial for diagnosing and managing conditions related to vitamin D deficiency or excess.
Product Introduction

The 25-Hydroxy Vitamin D Detection Kit utilizes quantum dot fluorescence immunoassay technology to provide accurate and reliable measurements of 25-OH-VD levels in human samples. This kit is essential for clinical diagnostics, offering a robust solution for assessing vitamin D status, which is vital for bone health, immune function, and overall well-being.

1. The kit features advanced quantum dot fluorescence technology, ensuring high sensitivity and specificity in detecting 25-OH-VD levels. This makes it a reliable tool for clinical diagnostics.
2. The test strip's structure includes multiple layers, such as the absorbent paper, nitrocellulose membrane, and quantum dot-labeled pad, each playing a critical role in the accurate detection of 25-OH-VD.
3. The kit is primarily used in clinical laboratories to measure 25-OH-VD levels in serum, plasma, and whole blood, aiding in the diagnosis and management of vitamin D-related disorders.

The 25-Hydroxy Vitamin D Detection Kit, also known as the 25-OH-VD Test Kit, is a cutting-edge diagnostic tool designed for precise measurement of vitamin D levels. Its advanced technology and robust design make it an indispensable resource for healthcare professionals.

Main Features

This kit offers high sensitivity, specificity, and ease of use, making it an ideal choice for clinical laboratories. Its quantum dot fluorescence technology ensures accurate and reliable results.

1. High sensitivity: The kit can detect low concentrations of 25-OH-VD, making it suitable for early diagnosis of vitamin D deficiency.
2. Specificity: The use of monoclonal antibodies ensures that the kit accurately identifies 25-OH-VD without cross-reactivity with other substances.
3. Ease of use: The kit is designed for straightforward operation, with clear instructions and minimal training required.
4. Stability: The components are stable under various storage conditions, ensuring consistent performance over time.
5. Versatility: The kit can be used with different sample types, including serum, plasma, and whole blood.

The 25-Hydroxy Vitamin D Detection Kit stands out for its high sensitivity, specificity, and user-friendly design. These features make it a reliable and efficient tool for clinical diagnostics, ensuring accurate assessment of vitamin D levels.

Clinical Applications

This kit is widely used in clinical settings to measure 25-OH-VD levels, aiding in the diagnosis and management of vitamin D-related conditions such as osteoporosis, rickets, and immune disorders.

1. Diagnosis of vitamin D deficiency: The kit helps identify individuals with low vitamin D levels, enabling timely intervention.
2. Monitoring vitamin D therapy: It is used to track the effectiveness of vitamin D supplementation in patients.
3. Research applications: The kit is also utilized in clinical studies to investigate the role of vitamin D in various health conditions.
4. Pediatric care: It is particularly useful in assessing vitamin D levels in children, who are at higher risk of deficiency.
5. Geriatric care: The kit aids in managing vitamin D levels in elderly patients, who often have reduced sun exposure and dietary intake.

The 25-Hydroxy Vitamin D Detection Kit is a versatile tool in clinical practice, essential for diagnosing and managing vitamin D-related conditions across different patient populations. Its accuracy and reliability make it a trusted choice for healthcare providers.

Purchasing Guide

When purchasing this kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your clinical needs.

1. Product specifications: Evaluate the kit's sensitivity, specificity, and compatibility with your laboratory equipment.
2. Product types: Choose between 20-test and 50-test formats based on your laboratory's volume and requirements.
3. Budget: Consider the cost per test and overall budget to ensure cost-effectiveness.
4. Usage scenarios: Assess the kit's suitability for different sample types and clinical applications.

Selecting the right 25-Hydroxy Vitamin D Detection Kit involves careful consideration of product specifications, types, budget, and usage scenarios. Making an informed choice ensures optimal performance and cost-effectiveness in clinical settings.

 Precautions

Proper handling and storage of the kit are essential to maintain its performance and ensure accurate results. Follow all instructions carefully to avoid errors.

1. Storage conditions: Store the kit at the recommended temperature to preserve the stability of its components.
2. Handling: Avoid contamination by using sterile techniques when handling samples and kit components.
3. Expiration date: Always check the expiration date before use to ensure the kit's effectiveness.
4. Calibration: Regularly calibrate your equipment to maintain accuracy in measurements.
5. Disposal: Dispose of used components according to local regulations to prevent environmental contamination.

Adhering to proper storage, handling, and disposal practices is crucial for the effective use of the 25-Hydroxy Vitamin D Detection Kit. Following these precautions ensures reliable results and prolongs the kit's shelf life.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files