Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
PTFE Coated Angiography Guidewire
The PTFE Coated Angiography Guidewire is a specialized medical device designed for vascular procedures. It consists of a core wire, safety wire, and an outer coil wire. The core wire can be either fixed or movable, and the distal tip of the guidewire comes in 'J' or straight configurations. Made from stainless steel with a PTFE (Polytetrafluoroethylene) coating, the guidewire ensures smooth movement during procedures. It is sterilized using ethylene oxide and is intended for single use.
Product English Name:
PTFE Coated Angiography Guidewire
Alias:
Fluoropolymer Coated Guidewire,Teflon Coated Guidewire
Intended Use:
This product is used in angiography or interventional procedures to access blood vessels percutaneously using the Seldinger technique. It facilitates the introduction of catheters and other devices into the vascular system, aiding in diagnostic imaging and therapeutic interventions.
Product Introduction

The PTFE Coated Angiography Guidewire is a critical tool in modern vascular interventions. Its design ensures smooth navigation through blood vessels, reducing friction and enhancing procedural efficiency. The guidewire's PTFE coating provides excellent lubricity, making it ideal for complex vascular pathways. It is available in various configurations to suit different clinical needs, ensuring versatility and reliability in medical settings.

1. The guidewire features a PTFE coating, which significantly reduces friction, allowing for smooth and precise movement within blood vessels. This coating also enhances the guidewire's durability and resistance to wear.
2. The structure includes a core wire, safety wire, and outer coil wire. The core wire can be fixed or movable, offering flexibility in handling. The distal tip is available in 'J' or straight forms, catering to different procedural requirements.
3. Primarily used in angiography and interventional procedures, the guidewire facilitates the introduction of catheters and other devices into the vascular system. Its design ensures minimal trauma to the vessel walls, making it a preferred choice for complex vascular interventions.

The PTFE Coated Angiography Guidewire, also known as the Fluoropolymer Coated Guidewire, is a versatile and reliable tool in vascular procedures. Its unique design and PTFE coating ensure smooth navigation and reduced friction, making it indispensable in modern medical interventions.

Main Features

The PTFE Coated Angiography Guidewire is designed for smooth navigation and precise control in vascular procedures. Its key features include a PTFE coating for reduced friction, a flexible core wire, and a choice of distal tip configurations.

1. The PTFE coating ensures minimal friction, allowing the guidewire to glide smoothly through blood vessels, reducing the risk of vessel damage.
2. The core wire can be fixed or movable, providing flexibility in handling and adaptability to different procedural needs.
3. The distal tip is available in 'J' or straight forms, catering to various anatomical structures and procedural requirements.
4. The guidewire is made from high-quality stainless steel, ensuring strength and durability during procedures.
5. It is sterilized using ethylene oxide, making it safe for single-use applications in sterile environments.

The PTFE Coated Angiography Guidewire stands out for its smooth navigation, flexibility, and durability. Its PTFE coating and versatile design make it an essential tool for vascular interventions, ensuring precision and safety in medical procedures.

Clinical Applications

The PTFE Coated Angiography Guidewire is widely used in clinical settings for vascular imaging and interventions. It is particularly valuable in complex procedures requiring precise navigation through intricate vascular pathways.

1. In diagnostic angiography, the guidewire facilitates the introduction of catheters for imaging contrast agents, aiding in the visualization of blood vessels.
2. During interventional procedures, it assists in the placement of stents, balloons, and other devices, ensuring accurate positioning within the vascular system.
3. The guidewire is used in percutaneous coronary interventions (PCI) to navigate through coronary arteries, enabling the treatment of blockages and stenoses.
4. It is also employed in peripheral vascular interventions, where precise navigation through narrow or tortuous vessels is required.
5. The guidewire's smooth movement and flexibility make it suitable for use in pediatric and geriatric patients, where delicate handling is crucial.

The PTFE Coated Angiography Guidewire is a versatile tool in clinical practice, essential for both diagnostic and therapeutic vascular procedures. Its ability to navigate complex vascular pathways with precision makes it invaluable in modern medicine.

Purchasing Guide

When purchasing the PTFE Coated Angiography Guidewire, consider factors such as product specifications, types, budget, and intended use to ensure the best fit for your clinical needs.

1. Evaluate the product parameters, including length, diameter, and tip configuration, to match the specific requirements of your procedures.
2. Choose between different types of guidewires, such as fixed or movable core wires, and 'J' or straight tips, based on the anatomical structures you will be navigating.
3. Consider your budget and the cost-effectiveness of the guidewire, ensuring it provides the necessary features without exceeding financial constraints.
4. Assess the intended use scenarios, such as diagnostic angiography or interventional procedures, to select a guidewire that offers the required performance and safety features.

Selecting the right PTFE Coated Angiography Guidewire involves careful consideration of product specifications, types, and intended use. By aligning these factors with your clinical needs, you can ensure optimal performance and cost-effectiveness in your medical procedures.

 Precautions

Proper handling and usage of the PTFE Coated Angiography Guidewire are crucial to ensure patient safety and procedural success. Adhering to guidelines and precautions can prevent complications and enhance outcomes.

1. Always inspect the guidewire for any signs of damage or defects before use. A compromised guidewire can lead to procedural complications.
2. Ensure that the guidewire is used within its intended scope, avoiding applications for which it is not designed, to prevent adverse events.
3. Follow proper sterilization and handling protocols to maintain the guidewire's integrity and prevent infections.
4. Monitor the guidewire's movement during procedures to avoid excessive force, which can cause vessel trauma or guidewire breakage.
5. Dispose of the guidewire properly after single use, adhering to medical waste disposal regulations to ensure environmental and patient safety.

Using the PTFE Coated Angiography Guidewire safely requires attention to detail and adherence to best practices. By following precautions and handling guidelines, healthcare providers can ensure successful outcomes and minimize risks in vascular procedures.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files