25-Hydroxy Vitamin D Detection Kit (Dry Fluorescence Immunochromatography)
The 25-Hydroxy Vitamin D Detection Kit is composed of a reagent card, which includes a reagent strip and a card shell. The reagent strip consists of five main components: a nitrocellulose membrane, a conjugate pad, a sample pad, an absorbent pad, and a tip. The nitrocellulose membrane contains 25-Hydroxy Vitamin D antigen and goat anti-chicken IgY. The conjugate pad is embedded with fluorescent microspheres labeled with 25-Hydroxy Vitamin D monoclonal antibody and chicken IgY. The kit also includes a diluent, which is primarily composed of PBS, a dissociating agent, and ProClin 300, with a pH of 7.4±1. Additional components include an instruction manual, optional pipettes, and anticoagulant tubes.
Product English Name:
25-Hydroxy Vitamin D Detection Kit (Dry Fluorescence Immunochromatography)
Alias:
Vitamin D Assay Kit,25(OH)D Test Kit
Intended Use:
This kit is designed for the in vitro quantitative detection of 25-Hydroxy Vitamin D levels in human serum, plasma, and whole blood. It is widely used in clinical laboratories to assess vitamin D status, which is crucial for bone health, immune function, and overall well-being.
Product Introduction

The 25-Hydroxy Vitamin D Detection Kit is a state-of-the-art diagnostic tool that utilizes dry fluorescence immunochromatography to accurately measure vitamin D levels in human samples. This kit is essential for healthcare providers to diagnose and monitor vitamin D deficiency or excess, which can have significant implications for patient health.

1. The kit features a highly sensitive and specific detection method, ensuring accurate and reliable results. The use of fluorescent microspheres enhances the detection sensitivity, making it suitable for low-concentration samples.
2. The reagent strip is composed of multiple layers, each serving a specific function in the detection process. The nitrocellulose membrane captures the target antigen, while the conjugate pad releases fluorescently labeled antibodies that bind to the antigen, producing a measurable signal.
3. The kit is designed for ease of use, with a straightforward procedure that can be performed in clinical settings. It includes all necessary components, such as the diluent and optional accessories, to ensure a smooth and efficient testing process.

The 25-Hydroxy Vitamin D Detection Kit, also known as the Vitamin D Assay Kit, is a comprehensive solution for measuring vitamin D levels in human samples. Its advanced technology and user-friendly design make it an indispensable tool for healthcare professionals.

Main Features

The main features of the 25-Hydroxy Vitamin D Detection Kit include high sensitivity, specificity, and ease of use. It is designed to provide accurate and reliable results in a clinical setting.

1. High Sensitivity: The kit utilizes fluorescent microspheres, which significantly enhance the detection sensitivity, allowing for the accurate measurement of low-concentration vitamin D levels.
2. Specificity: The kit is highly specific to 25-Hydroxy Vitamin D, ensuring that other compounds do not interfere with the results.
3. Ease of Use: The kit is designed for straightforward operation, with a simple procedure that can be easily performed by laboratory personnel.
4. Comprehensive Components: The kit includes all necessary components, such as the reagent card, diluent, and optional accessories, ensuring a complete testing solution.
5. Reliable Results: The kit provides consistent and reliable results, making it a trusted tool for clinical diagnostics.

The 25-Hydroxy Vitamin D Detection Kit stands out for its high sensitivity, specificity, and user-friendly design. It is a reliable and efficient tool for healthcare professionals to assess vitamin D levels in patients.

Clinical Applications

The 25-Hydroxy Vitamin D Detection Kit is widely used in clinical settings to diagnose and monitor vitamin D deficiency or excess. It is an essential tool for assessing bone health, immune function, and overall well-being.

1. Diagnosis of Vitamin D Deficiency: The kit is used to diagnose vitamin D deficiency, which can lead to bone disorders such as osteoporosis and rickets.
2. Monitoring Vitamin D Levels: The kit is used to monitor vitamin D levels in patients undergoing treatment for vitamin D deficiency or excess.
3. Research Applications: The kit is also used in research studies to investigate the role of vitamin D in various health conditions.
4. Public Health Screening: The kit is used in public health programs to screen populations for vitamin D deficiency, particularly in regions with limited sunlight exposure.
5. Clinical Trials: The kit is used in clinical trials to assess the efficacy of vitamin D supplements and treatments.

The 25-Hydroxy Vitamin D Detection Kit is a versatile tool used in clinical diagnostics, research, and public health. Its ability to accurately measure vitamin D levels makes it invaluable for assessing and managing vitamin D-related health conditions.

Purchasing Guide

When purchasing the 25-Hydroxy Vitamin D Detection Kit, it is important to consider product specifications, types, budget, and intended use to ensure the best fit for your clinical needs.

1. Product Specifications: Evaluate the kit's sensitivity, specificity, and detection range to ensure it meets your laboratory's requirements.
2. Product Types: Consider the different types of kits available, such as those designed for specific sample types (serum, plasma, or whole blood).
3. Budget: Determine your budget and compare the cost of different kits, taking into account the number of tests per kit and any additional accessories required.
4. Intended Use: Consider the intended use of the kit, whether for routine clinical diagnostics, research, or public health screening, to ensure it aligns with your needs.

Purchasing the 25-Hydroxy Vitamin D Detection Kit requires careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can select the best kit for your clinical needs.

 Precautions

When using the 25-Hydroxy Vitamin D Detection Kit, it is important to follow all instructions and precautions to ensure accurate results and safe handling of the kit components.

1. Proper Storage: Store the kit at the recommended temperature to maintain the stability and effectiveness of the reagents.
2. Sample Handling: Handle samples with care to avoid contamination, which can affect the accuracy of the results.
3. Reagent Preparation: Follow the instructions for preparing and using the reagents to ensure proper functioning of the kit.
4. Disposal: Dispose of used components according to local regulations to prevent environmental contamination.
5. Training: Ensure that laboratory personnel are properly trained in the use of the kit to avoid errors and ensure consistent results.

Using the 25-Hydroxy Vitamin D Detection Kit requires attention to proper storage, sample handling, reagent preparation, disposal, and training. By following these precautions, you can ensure accurate results and safe handling of the kit.