Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
PTCA Guide Wire
The PTCA Guide Wire consists of two main parts: the PTCA guide wire and the extension wire. The PTCA guide wire includes the AG and AGH series, which are composed of a core wire (Austenitic stainless steel SUS304), a radiopaque coil wire (Platinum-Nickel alloy), and a stainless steel coil wire (Austenitic stainless steel SUS316). The AG and AGH wires are coated with PTFE (Polytetrafluoroethylene) at the proximal end, and the AGH series additionally features a hydrophilic coating. The extension wire is made of a coil wire (Austenitic stainless steel SUS304) and an extension tube (Nickel-Titanium alloy), also coated with PTFE. The product is sterilized with ethylene oxide, intended for single use, and has a shelf life of 3 years.
Product English Name:
PTCA Guide Wire
Alias:
Coronary Guide Wire,Interventional Guide Wire
Intended Use:
The PTCA Guide Wire is designed to guide diagnostic or interventional devices within coronary arteries. The extension wire is used in coronary artery procedures (PTCA) and angioplasty (PTA) to connect with an already inserted guide wire if its length is less than 300cm, thereby extending its working length without direct contact with the human body.
Product Introduction

The PTCA Guide Wire is a critical component in cardiovascular interventions, specifically designed to navigate and position diagnostic and therapeutic devices within the coronary arteries. Its construction ensures flexibility, durability, and radiopacity, making it indispensable in complex coronary procedures.

1. The PTCA Guide Wire is characterized by its high flexibility and torque control, which are essential for navigating through tortuous coronary arteries. The AG and AGH series offer different levels of hydrophilicity, with the AGH series providing enhanced lubricity for smoother navigation.
2. Structurally, the guide wire is composed of a core wire made from Austenitic stainless steel SUS304, ensuring strength and flexibility. The radiopaque coil wire, made from Platinum-Nickel alloy, provides visibility under X-ray, while the stainless steel coil wire adds durability. The PTFE coating on the AG and AGH series reduces friction, and the AGH series includes a hydrophilic coating for improved performance.
3. The primary use of the PTCA Guide Wire is to guide diagnostic or interventional devices within the coronary arteries. The extension wire is particularly useful in procedures where the initial guide wire is too short, allowing for extended reach without compromising safety or performance.

The PTCA Guide Wire, with its AG and AGH series, stands out for its advanced design and material composition, ensuring optimal performance in coronary interventions. Its ability to navigate complex vascular structures with precision makes it a trusted tool in cardiovascular procedures.

Main Features

The PTCA Guide Wire is renowned for its precision, flexibility, and radiopacity, making it an essential tool in coronary interventions. Its design ensures smooth navigation through complex vascular structures.

1. The PTCA Guide Wire offers exceptional torque control, allowing physicians to navigate through tortuous coronary arteries with ease. This feature is crucial for precise placement of diagnostic and therapeutic devices.
2. The radiopaque coil wire, made from Platinum-Nickel alloy, provides excellent visibility under X-ray, ensuring accurate positioning during procedures. This is particularly important in complex interventions where precision is paramount.
3. The AG and AGH series are coated with PTFE, reducing friction and enhancing the wire's ability to glide through the vasculature. The AGH series also includes a hydrophilic coating, which further improves lubricity and performance.
4. The core wire, made from Austenitic stainless steel SUS304, provides the necessary strength and flexibility, ensuring the guide wire can withstand the rigors of coronary interventions without compromising performance.
5. The extension wire, made from Nickel-Titanium alloy, is designed to extend the working length of the guide wire, making it suitable for procedures where longer reach is required. Its PTFE coating ensures smooth operation and reduces the risk of complications.

The PTCA Guide Wire's main features, including its torque control, radiopacity, and advanced coatings, make it an indispensable tool in coronary interventions. Its design ensures both safety and efficacy, providing physicians with the confidence to perform complex procedures.

Clinical Applications

The PTCA Guide Wire is widely used in coronary interventions, including diagnostic procedures and therapeutic interventions such as angioplasty. Its design ensures precise navigation and placement of devices within the coronary arteries.

1. In diagnostic procedures, the PTCA Guide Wire is used to guide catheters and other diagnostic devices to specific locations within the coronary arteries, allowing for accurate assessment of vascular conditions.
2. During angioplasty, the guide wire is essential for positioning balloons and stents within the coronary arteries. Its flexibility and torque control ensure precise placement, which is critical for successful outcomes.
3. The AGH series, with its hydrophilic coating, is particularly useful in complex interventions where smooth navigation through tortuous vessels is required. This reduces the risk of vessel trauma and improves procedural efficiency.
4. The extension wire is used in procedures where the initial guide wire is too short, allowing for extended reach without the need for additional devices. This is particularly useful in long or complex interventions.
5. The PTCA Guide Wire is also used in conjunction with other interventional devices, such as atherectomy catheters, to facilitate the removal of plaque from coronary arteries. Its design ensures compatibility and smooth operation with these devices.

The PTCA Guide Wire's clinical applications are vast, ranging from diagnostic procedures to complex therapeutic interventions. Its design ensures precise navigation and placement, making it a trusted tool in the field of interventional cardiology.

Purchasing Guide

When purchasing the PTCA Guide Wire, it is important to consider factors such as product specifications, types, budget, and intended use. This guide provides essential information to help make an informed decision.

1. Product specifications, including length, diameter, and coating type, should be carefully considered to ensure the guide wire meets the specific needs of the procedure. The AG and AGH series offer different features, so selecting the appropriate series is crucial.
2. The type of guide wire, whether it is the AG or AGH series, should be chosen based on the procedure's requirements. The AGH series, with its hydrophilic coating, is ideal for complex interventions, while the AG series is suitable for standard procedures.
3. Budget considerations are important, as the cost of the guide wire can vary depending on the series and specifications. It is essential to balance cost with the need for advanced features to ensure optimal outcomes.
4. The intended use of the guide wire, whether for diagnostic or therapeutic procedures, should guide the selection process. Understanding the specific requirements of the procedure will help in choosing the most appropriate guide wire.

Purchasing the PTCA Guide Wire requires careful consideration of product specifications, types, budget, and intended use. This guide aims to provide the necessary information to make an informed decision, ensuring the selected guide wire meets the specific needs of the procedure.

 Precautions

When using the PTCA Guide Wire, it is important to follow specific precautions to ensure safety and efficacy. These include proper handling, storage, and disposal, as well as adherence to procedural guidelines.

1. Proper handling of the guide wire is essential to prevent damage or contamination. It should be handled with care, avoiding sharp bends or kinks that could compromise its integrity.
2. The guide wire should be stored in a clean, dry environment, away from direct sunlight and extreme temperatures. This ensures the product remains in optimal condition until use.
3. Disposal of the guide wire should be done in accordance with local regulations for medical waste. Since the product is intended for single use, it should not be reused under any circumstances.
4. Adherence to procedural guidelines is crucial to ensure the safe and effective use of the guide wire. This includes proper sterilization techniques and the use of compatible devices.
5. It is important to monitor the patient closely during and after the procedure to detect any potential complications related to the use of the guide wire. Prompt action should be taken if any issues arise.

The PTCA Guide Wire requires careful handling, storage, and disposal to ensure safety and efficacy. Adherence to procedural guidelines and close patient monitoring are essential to minimize risks and achieve successful outcomes.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files