Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
25-Hydroxy Vitamin D Detection Kit (Dry Immunofluorescence Method)
The kit consists of a detection card, an ID card, and an instruction manual. The detection card includes a test strip and a card shell. The test strip is composed of a conjugate pad (coated with fluorescent microsphere-labeled mouse anti-25-OH-VD monoclonal antibody), a nitrocellulose membrane (with 25-OH-VD antigen coated on the T line and goat anti-mouse IgG polyclonal antibody on the C line), a PVC board, a sample pad, and absorbent paper. The ID card contains built-in calibration curve information.
Product English Name:
25-Hydroxy Vitamin D Detection Kit (Dry Immunofluorescence Method)
Alias:
25-OH-VD Test Kit,Vitamin D Assay Kit
Intended Use:
This kit is designed for the in vitro quantitative detection of 25-hydroxy vitamin D (25-OH-VD) levels in human samples, including serum, whole blood, or plasma.
Product Introduction

The 25-Hydroxy Vitamin D Detection Kit (Dry Immunofluorescence Method) is a state-of-the-art diagnostic tool designed to accurately measure the levels of 25-OH-VD in human samples. This kit is essential for assessing vitamin D status, which is crucial for bone health, immune function, and overall well-being. The kit's innovative design ensures high sensitivity and specificity, making it a reliable choice for clinical and research applications.

1. The kit features a unique dry immunofluorescence method, which enhances the accuracy and reliability of the test results. The use of fluorescent microspheres allows for precise detection of 25-OH-VD levels, even at low concentrations.
2. The test strip is composed of multiple layers, including a conjugate pad, nitrocellulose membrane, PVC board, sample pad, and absorbent paper. Each component is carefully designed to ensure optimal performance and ease of use.
3. The kit is primarily used for the quantitative detection of 25-OH-VD in human samples. It is widely used in clinical settings to diagnose vitamin D deficiency, monitor treatment efficacy, and conduct research on vitamin D metabolism.

The 25-Hydroxy Vitamin D Detection Kit, also known as the 25-OH-VD Test Kit, is a highly specialized tool for measuring vitamin D levels. Its advanced design and precise detection capabilities make it an indispensable resource for healthcare professionals and researchers alike.

Main Features

The main features of the 25-Hydroxy Vitamin D Detection Kit include its high sensitivity, specificity, and ease of use. The kit employs a dry immunofluorescence method, which ensures accurate and reliable results.

1. The kit utilizes fluorescent microspheres for detection, which enhances sensitivity and allows for the detection of low concentrations of 25-OH-VD.
2. The test strip is designed with multiple layers, each contributing to the overall accuracy and reliability of the test. The conjugate pad, nitrocellulose membrane, and other components work together to ensure optimal performance.
3. The kit is easy to use, with a straightforward procedure that can be performed in clinical or research settings. The included ID card simplifies the calibration process, ensuring accurate results every time.
4. The kit is highly specific, with minimal cross-reactivity with other substances. This ensures that the results are accurate and reliable, even in complex biological samples.
5. The kit is designed for use with a variety of human samples, including serum, whole blood, and plasma. This versatility makes it a valuable tool for a wide range of applications.

The 25-Hydroxy Vitamin D Detection Kit stands out for its precision, ease of use, and versatility. Its advanced features make it a top choice for professionals seeking reliable vitamin D level measurements.

Clinical Applications

The 25-Hydroxy Vitamin D Detection Kit is widely used in clinical settings to diagnose and monitor vitamin D deficiency. It is also used in research to study vitamin D metabolism and its impact on health.

1. The kit is commonly used in clinical diagnostics to assess vitamin D status in patients. It helps in diagnosing vitamin D deficiency, which is linked to various health issues, including osteoporosis and immune dysfunction.
2. In research settings, the kit is used to study the role of vitamin D in various physiological processes. It provides accurate data that can be used to understand the impact of vitamin D on health and disease.
3. The kit is also used to monitor the efficacy of vitamin D supplementation. By measuring 25-OH-VD levels before and after treatment, healthcare providers can assess the effectiveness of the intervention.
4. In epidemiological studies, the kit is used to measure vitamin D levels in large populations. This data can be used to identify trends and risk factors associated with vitamin D deficiency.
5. The kit is also used in clinical trials to evaluate new treatments for vitamin D deficiency. Its high sensitivity and specificity make it an ideal tool for assessing the impact of new therapies.

The 25-Hydroxy Vitamin D Detection Kit is a versatile tool with a wide range of clinical and research applications. Its ability to provide accurate and reliable data makes it an essential resource for healthcare professionals and researchers.

Purchasing Guide

When purchasing the 25-Hydroxy Vitamin D Detection Kit, it is important to consider factors such as product specifications, types, budget, and intended use. This guide provides essential information to help you make an informed decision.

1. Product specifications: Ensure that the kit meets your specific requirements, including sensitivity, specificity, and compatibility with your laboratory equipment.
2. Product types: There are different types of kits available, each designed for specific applications. Choose the one that best suits your needs, whether for clinical diagnostics or research.
3. Budget: Consider your budget when selecting a kit. While high-quality kits may be more expensive, they often provide better performance and reliability.
4. Intended use: Determine the primary use of the kit, whether for routine clinical testing, research, or large-scale epidemiological studies. This will help you select the most appropriate kit for your needs.

Purchasing the right 25-Hydroxy Vitamin D Detection Kit requires careful consideration of various factors. By understanding your needs and the available options, you can make a well-informed decision that ensures optimal results.

 Precautions

When using the 25-Hydroxy Vitamin D Detection Kit, it is important to follow all safety and handling precautions to ensure accurate results and prevent contamination.

1. Always wear appropriate personal protective equipment (PPE), including gloves and lab coats, when handling the kit components.
2. Ensure that all samples are handled and stored according to the manufacturer's instructions to prevent degradation and ensure accurate results.
3. Follow the calibration and quality control procedures outlined in the instruction manual to maintain the accuracy and reliability of the test results.
4. Dispose of all used materials, including test strips and sample containers, in accordance with local regulations and laboratory safety protocols.
5. Regularly check the expiration date of the kit components and replace any expired items to ensure the integrity of the test results.

Proper handling and adherence to safety protocols are essential when using the 25-Hydroxy Vitamin D Detection Kit. By following these precautions, you can ensure accurate results and maintain a safe laboratory environment.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files