The VascuTrak PTA Dilatation Catheter is a specialized medical device designed for the treatment of vascular stenoses and obstructions. It features a semi-compliant balloon and a robust shaft construction, allowing for precise and effective dilation of narrowed or blocked arteries. The catheter is engineered to accommodate various guidewire sizes and includes radiopaque markers for accurate positioning during procedures. Its single-use design ensures sterility and safety in clinical applications.
1. The VascuTrak PTA Dilatation Catheter is characterized by its semi-compliant balloon, which allows for controlled expansion and minimizes the risk of vessel injury. The catheter's soft shaft ensures flexibility and ease of navigation through complex vascular structures.
2. The catheter's construction includes a stainless steel core wire that runs parallel to the expansion lumen, providing structural integrity and support during dilation. The radiopaque marker bands on the outer core wire facilitate precise positioning and visualization under fluoroscopy.
3. The primary use of the VascuTrak PTA Dilatation Catheter is to treat stenoses in peripheral arteries and dialysis arteriovenous fistulas. It is also employed in the re-expansion of various types of stents, making it a versatile tool in interventional radiology and vascular surgery.
The VascuTrak PTA Dilatation Catheter, also known as the Balloon Catheter, is a highly effective device for treating vascular stenoses and obstructions. Its design, featuring a semi-compliant balloon and a robust shaft, ensures precise and safe dilation. The catheter's versatility in treating various arterial conditions and its compatibility with different stents make it an indispensable tool in modern vascular interventions.
The VascuTrak PTA Dilatation Catheter offers precise dilation of stenosed arteries, compatibility with various guidewires, and radiopaque markers for accurate positioning. Its semi-compliant balloon ensures controlled expansion, minimizing vessel trauma.
1. The semi-compliant balloon allows for controlled and gradual expansion, reducing the risk of vessel injury and ensuring effective dilation of stenoses.
2. The catheter's compatibility with 0.018″ and 0.014″ guidewires provides flexibility in navigating through complex vascular structures, enhancing procedural success.
3. Radiopaque marker bands on the outer core wire enable precise positioning and visualization under fluoroscopy, ensuring accurate placement of the balloon during dilation.
4. The robust construction of the catheter, including a stainless steel core wire, provides structural support and durability during the dilation process.
5. The single-use design of the catheter ensures sterility and safety, reducing the risk of infection and contamination in clinical settings.
The VascuTrak PTA Dilatation Catheter stands out for its precise dilation capabilities, compatibility with various guidewires, and robust construction. Its semi-compliant balloon and radiopaque markers ensure safe and effective treatment of vascular stenoses, making it a reliable choice for interventional procedures.
The VascuTrak PTA Dilatation Catheter is widely used in interventional radiology and vascular surgery for the treatment of arterial stenoses and obstructions. Its applications include dilation of peripheral arteries, treatment of dialysis arteriovenous fistulas, and re-expansion of stents.
1. The catheter is commonly used in the dilation of stenosed iliac, femoral, and renal arteries, restoring blood flow and alleviating symptoms of peripheral artery disease.
2. It is effective in treating obstructions in dialysis arteriovenous fistulas, ensuring the patency of the access site for hemodialysis.
3. The catheter is employed in the re-expansion of balloon-expandable stents, self-expanding stents, and covered stents, maintaining the structural integrity of the stents and preventing restenosis.
4. In complex vascular interventions, the catheter's flexibility and compatibility with various guidewires facilitate navigation through tortuous vessels, enhancing procedural success.
5. The single-use design of the catheter ensures sterility and safety, making it suitable for use in a wide range of clinical settings, including hospitals and outpatient clinics.
The VascuTrak PTA Dilatation Catheter is a versatile tool in the treatment of arterial stenoses and obstructions. Its applications in peripheral artery disease, dialysis access maintenance, and stent re-expansion make it an essential device in interventional radiology and vascular surgery. The catheter's design ensures safe and effective treatment, contributing to improved patient outcomes.
When purchasing the VascuTrak PTA Dilatation Catheter, consider factors such as product specifications, types, budget, and intended use. Ensure compatibility with existing equipment and adherence to clinical requirements.
1. Evaluate the product specifications, including balloon size, guidewire compatibility, and shaft length, to ensure the catheter meets the specific needs of your clinical procedures.
2. Consider the different types of PTA catheters available, such as those with varying balloon diameters and lengths, to select the most appropriate option for your patients.
3. Establish a procurement budget that accounts for the cost of the catheter, as well as any additional accessories or equipment required for its use.
4. Assess the intended use of the catheter, including the types of vascular interventions it will be used for, to ensure it aligns with your clinical objectives and patient needs.
Purchasing the VascuTrak PTA Dilatation Catheter requires careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can ensure that the catheter meets your clinical needs and contributes to successful patient outcomes.
When using the VascuTrak PTA Dilatation Catheter, it is essential to follow proper handling and sterilization procedures to ensure patient safety and device efficacy. Adhere to clinical guidelines and manufacturer instructions.
1. Ensure the catheter is properly sterilized and stored before use to prevent contamination and infection.
2. Follow the manufacturer's instructions for guidewire insertion and balloon inflation to avoid vessel injury or catheter malfunction.
3. Monitor the patient's vital signs and vascular response during the procedure to detect any adverse reactions or complications.
4. Dispose of the catheter according to medical waste disposal regulations after single use to prevent cross-contamination.
5. Train clinical staff on the proper use and handling of the catheter to ensure safe and effective procedures.
Using the VascuTrak PTA Dilatation Catheter requires adherence to proper handling, sterilization, and procedural guidelines. By following these precautions, you can ensure patient safety, device efficacy, and successful clinical outcomes.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.