Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
Sterling SL OTW PTA Balloon Dilatation Catheter
The Sterling SL OTW PTA Balloon Dilatation Catheter is a coaxial device designed for peripheral vascular interventions. It features a handle made of polycarbonate, a buffer of polyurethane, an outer shaft of nylon 12, and a triple-layer inner shaft composed of Pebax 7233, polyethylene copolymer, and high-density polyethylene. The balloon is made of Pebax 7233, with an 18K gold marker band, a proximal marker of hot-stamped foil, a buffer tip of nylon elastomer, and a balloon protector of PTFE. The catheter's distal end is coated with hydrophilic (Bioslide) and hydrophobic (Xtra) coatings. It is sterilized with ethylene oxide, intended for single use, and has a two-year shelf life.
Product English Name:
Sterling SL OTW PTA Balloon Dilatation Catheter
Alias:
PTA Balloon Catheter,Peripheral Balloon Catheter
Intended Use:
The Sterling SL OTW PTA Balloon Dilatation Catheter is used for percutaneous transluminal angioplasty (PTA) in the peripheral vascular system, including the iliac, femoral, iliofemoral, popliteal, infrapopliteal, and renal arteries. It is also suitable for treating occlusive lesions in natural or synthetic dialysis arteriovenous fistulas.
Product Introduction

The Sterling SL OTW PTA Balloon Dilatation Catheter is a state-of-the-art medical device designed for minimally invasive vascular procedures. Its advanced coaxial design and high-quality materials ensure precise and effective treatment of peripheral vascular diseases. The catheter's hydrophilic and hydrophobic coatings enhance maneuverability and reduce friction during insertion, making it a reliable tool for interventional radiologists and vascular surgeons.

1. The Sterling SL OTW PTA Balloon Dilatation Catheter is known for its exceptional flexibility and pushability, allowing for smooth navigation through complex vascular structures. Its coaxial design ensures optimal performance during angioplasty procedures.
2. The catheter is composed of multiple layers, including a polycarbonate handle, a polyurethane buffer, and a triple-layer inner shaft made of Pebax 7233, polyethylene copolymer, and high-density polyethylene. These materials provide durability and precision during use.
3. The Sterling SL OTW PTA Balloon Dilatation Catheter is specifically designed for treating occlusive lesions in peripheral arteries and dialysis arteriovenous fistulas. Its hydrophilic and hydrophobic coatings facilitate easy insertion and reduce the risk of vessel trauma.

The Sterling SL OTW PTA Balloon Dilatation Catheter, also known as the PTA Balloon Catheter, is a versatile and reliable tool for vascular interventions. Its innovative design and high-quality materials make it a preferred choice for treating peripheral vascular diseases and dialysis-related occlusions.

Main Features

The Sterling SL OTW PTA Balloon Dilatation Catheter offers exceptional performance in peripheral vascular interventions. Its key features include a coaxial design, hydrophilic and hydrophobic coatings, and a durable construction for precise and effective treatment.

1. The catheter's coaxial design ensures optimal pushability and flexibility, enabling smooth navigation through tortuous vessels.
2. The hydrophilic coating (Bioslide) reduces friction during insertion, while the hydrophobic coating (Xtra) enhances durability and performance.
3. The triple-layer inner shaft, made of Pebax 7233, polyethylene copolymer, and high-density polyethylene, provides excellent kink resistance and torque control.
4. The 18K gold marker band and proximal hot-stamped foil marker ensure accurate positioning during procedures.
5. The PTFE balloon protector and nylon elastomer buffer tip enhance safety and ease of use.

The Sterling SL OTW PTA Balloon Dilatation Catheter stands out for its advanced features, including its coaxial design, dual coatings, and durable construction. These attributes make it a reliable and effective tool for vascular interventions.

Clinical Applications

The Sterling SL OTW PTA Balloon Dilatation Catheter is widely used in clinical settings for treating peripheral vascular diseases and dialysis-related occlusions. Its precision and ease of use make it a valuable tool for interventional radiologists and vascular surgeons.

1. The catheter is commonly used for percutaneous transluminal angioplasty (PTA) in the iliac, femoral, and popliteal arteries, providing effective treatment for occlusive lesions.
2. It is also employed in the treatment of infrapopliteal and renal artery stenosis, offering a minimally invasive solution for complex vascular conditions.
3. The Sterling SL OTW PTA Balloon Dilatation Catheter is particularly useful in managing occlusions in dialysis arteriovenous fistulas, ensuring uninterrupted dialysis treatment.
4. Its hydrophilic and hydrophobic coatings reduce the risk of vessel trauma, making it suitable for patients with fragile or calcified vessels.
5. The catheter's precise markers and durable construction ensure accurate and safe deployment during procedures.

The Sterling SL OTW PTA Balloon Dilatation Catheter is a versatile and reliable tool in clinical practice. Its ability to treat a wide range of peripheral vascular conditions and dialysis-related occlusions makes it an essential device for vascular interventions.

Purchasing Guide

When purchasing the Sterling SL OTW PTA Balloon Dilatation Catheter, it is essential to consider product specifications, types, budget, and intended use to ensure optimal performance and cost-effectiveness.

1. Product parameters such as balloon diameter, length, and rated burst pressure should align with the specific clinical requirements.
2. The catheter is available in various types, including over-the-wire (OTW) and rapid exchange (RX) models, each suited for different procedural needs.
3. Budget considerations should include not only the initial purchase cost but also the potential for reduced procedure times and improved patient outcomes.
4. The catheter is ideal for use in interventional radiology and vascular surgery settings, particularly for complex peripheral vascular cases.

Purchasing the Sterling SL OTW PTA Balloon Dilatation Catheter requires careful consideration of product specifications, types, and budget. Its versatility and performance make it a valuable investment for vascular interventions.

 Precautions

Proper handling and use of the Sterling SL OTW PTA Balloon Dilatation Catheter are crucial to ensure patient safety and device effectiveness. Key precautions include avoiding excessive force, ensuring proper sterilization, and adhering to single-use guidelines.

1. Avoid applying excessive force during insertion or inflation, as this may cause vessel damage or catheter rupture.
2. Ensure the catheter is properly sterilized and stored according to manufacturer guidelines to maintain its integrity.
3. The catheter is intended for single use only; reusing it may compromise patient safety and device performance.
4. Monitor the patient for signs of adverse reactions, such as vessel dissection or thrombosis, during and after the procedure.
5. Follow all local regulations and hospital protocols for the safe disposal of used catheters.

The Sterling SL OTW PTA Balloon Dilatation Catheter requires careful handling and adherence to safety protocols. By following these precautions, healthcare providers can ensure optimal outcomes and patient safety during vascular interventions.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files