Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
Sterling Monorail PTA Balloon Dilatation Catheter
The Sterling Monorail PTA Balloon Dilatation Catheter is a rapid-exchange balloon catheter designed for peripheral vascular interventions. It features a semi-compliant balloon fixed at its distal end and a coaxial shaft design. The outer lumen is used for balloon inflation, while the inner lumen, made of HDPE and dye, accommodates guidewires of 0.014in/0.018in (0.36mm/0.46mm) diameter, facilitating smooth catheter advancement through narrow lesions. The catheter has a tapered tip for easier navigation and two radiopaque markers for precise balloon positioning under X-ray guidance. It is sterilized with ethylene oxide and intended for single use.
Product English Name:
Sterling Monorail PTA Balloon Dilatation Catheter
Alias:
PTA Balloon Catheter,Monorail Balloon Catheter
Intended Use:
The Sterling Monorail PTA Balloon Dilatation Catheter is used for percutaneous transluminal angioplasty (PTA) in the peripheral vascular system, including the iliac, femoral, popliteal, infrapopliteal, renal, and carotid arteries. It is also suitable for treating obstructive lesions in native or synthetic dialysis arteriovenous fistulas and for post-dilation of balloon-expandable or self-expanding stents in peripheral vessels.
Product Introduction

The Sterling Monorail PTA Balloon Dilatation Catheter is a state-of-the-art medical device designed for minimally invasive vascular interventions. Its rapid-exchange design and semi-compliant balloon make it highly effective in treating peripheral vascular diseases. The catheter's coaxial shaft and tapered tip ensure smooth navigation through narrow and tortuous vessels, while the radiopaque markers provide precise positioning under X-ray guidance. This product is a reliable tool for interventional radiologists and vascular surgeons.

1. The Sterling Monorail PTA Balloon Dilatation Catheter features a semi-compliant balloon that allows for controlled expansion and minimizes the risk of vessel trauma. Its rapid-exchange design enables quick and efficient catheter exchanges, reducing procedure time.
2. The catheter's coaxial shaft consists of an outer lumen for balloon inflation and an inner lumen made of HDPE and dye, which accommodates guidewires of 0.014in/0.018in diameter. This design ensures smooth catheter advancement and precise placement in narrow lesions.
3. The Sterling Monorail PTA Balloon Dilatation Catheter is used for percutaneous transluminal angioplasty in the peripheral vascular system, including the iliac, femoral, popliteal, infrapopliteal, renal, and carotid arteries. It is also effective in treating obstructive lesions in dialysis arteriovenous fistulas and for post-dilation of stents.

The Sterling Monorail PTA Balloon Dilatation Catheter, also known as the PTA Balloon Catheter or Monorail Balloon Catheter, is a versatile and reliable tool for peripheral vascular interventions. Its innovative design and advanced features make it a preferred choice for interventional radiologists and vascular surgeons. Whether treating obstructive lesions or performing post-dilation of stents, this catheter delivers consistent performance and excellent clinical outcomes.

Main Features

The Sterling Monorail PTA Balloon Dilatation Catheter offers several key features, including a semi-compliant balloon, rapid-exchange design, coaxial shaft, and radiopaque markers. These features ensure precise, efficient, and safe vascular interventions.

1. The semi-compliant balloon allows for controlled expansion, reducing the risk of vessel trauma and ensuring optimal dilation of stenotic lesions.
2. The rapid-exchange design enables quick and efficient catheter exchanges, minimizing procedure time and improving workflow in the catheterization lab.
3. The coaxial shaft design, with an outer lumen for balloon inflation and an inner lumen for guidewire passage, ensures smooth catheter advancement and precise placement in narrow and tortuous vessels.
4. Two radiopaque markers, located at the proximal and distal ends of the balloon, provide precise positioning under X-ray guidance, enhancing the accuracy of the procedure.
5. The tapered tip of the catheter facilitates easier navigation through narrow lesions, reducing the risk of vessel injury and improving procedural success rates.

The Sterling Monorail PTA Balloon Dilatation Catheter is a highly effective tool for peripheral vascular interventions, thanks to its semi-compliant balloon, rapid-exchange design, and coaxial shaft. Its radiopaque markers and tapered tip further enhance its performance, making it a reliable choice for interventional radiologists and vascular surgeons. Whether treating obstructive lesions or performing post-dilation of stents, this catheter delivers consistent and excellent results.

Clinical Applications

The Sterling Monorail PTA Balloon Dilatation Catheter is widely used in clinical settings for percutaneous transluminal angioplasty in the peripheral vascular system. It is also effective in treating obstructive lesions in dialysis arteriovenous fistulas and for post-dilation of stents.

1. The catheter is used for percutaneous transluminal angioplasty (PTA) in the iliac, femoral, popliteal, infrapopliteal, renal, and carotid arteries, providing effective treatment for peripheral vascular diseases.
2. It is also used to treat obstructive lesions in native or synthetic dialysis arteriovenous fistulas, improving blood flow and dialysis efficiency.
3. The Sterling Monorail PTA Balloon Dilatation Catheter is effective for post-dilation of balloon-expandable or self-expanding stents in peripheral vessels, ensuring optimal stent deployment and vessel patency.
4. Its rapid-exchange design and semi-compliant balloon make it a preferred choice for interventional radiologists and vascular surgeons, reducing procedure time and improving clinical outcomes.
5. The catheter's radiopaque markers and tapered tip enhance its performance in complex vascular interventions, providing precise positioning and smooth navigation through narrow lesions.

The Sterling Monorail PTA Balloon Dilatation Catheter is a versatile and reliable tool for a wide range of clinical applications in peripheral vascular interventions. Its advanced features, including the semi-compliant balloon, rapid-exchange design, and radiopaque markers, make it a preferred choice for treating obstructive lesions and performing post-dilation of stents. Whether used in the iliac, femoral, or renal arteries, or in dialysis arteriovenous fistulas, this catheter delivers consistent and excellent clinical outcomes.

Purchasing Guide

When purchasing the Sterling Monorail PTA Balloon Dilatation Catheter, consider factors such as product specifications, types, budget, and intended use to ensure the best fit for your clinical needs.

1. Product specifications: Ensure the catheter's diameter, length, and balloon size match the requirements of your procedures. The Sterling Monorail PTA Balloon Dilatation Catheter is available in various sizes to accommodate different vascular interventions.
2. Product types: Choose between different models based on your specific clinical needs, such as the type of vessel being treated and the complexity of the procedure.
3. Budget: Consider the cost-effectiveness of the catheter, balancing its advanced features with your institution's budget constraints.
4. Intended use: Evaluate the catheter's suitability for your intended applications, such as percutaneous transluminal angioplasty, treatment of dialysis arteriovenous fistulas, or post-dilation of stents.

Purchasing the Sterling Monorail PTA Balloon Dilatation Catheter requires careful consideration of product specifications, types, budget, and intended use. By selecting the right catheter for your clinical needs, you can ensure optimal performance and cost-effectiveness in your vascular interventions.

 Precautions

When using the Sterling Monorail PTA Balloon Dilatation Catheter, follow proper handling and procedural guidelines to ensure patient safety and optimal outcomes.

1. Ensure the catheter is properly sterilized and intended for single use only. Do not reuse or reprocess the catheter, as this may compromise its safety and effectiveness.
2. Carefully inspect the catheter for any damage or defects before use. Do not use if the packaging is compromised or if the catheter appears damaged.
3. Follow the manufacturer's instructions for proper catheter handling, insertion, and inflation. Avoid excessive force during catheter advancement to prevent vessel injury.
4. Monitor the patient closely during and after the procedure for any signs of complications, such as bleeding, vessel dissection, or allergic reactions to contrast media.
5. Dispose of the used catheter and related materials according to local regulations and institutional protocols for medical waste disposal.

Using the Sterling Monorail PTA Balloon Dilatation Catheter requires adherence to proper handling and procedural guidelines to ensure patient safety and optimal outcomes. By following the manufacturer's instructions and monitoring the patient closely, you can minimize the risk of complications and achieve successful vascular interventions.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files