The Coyote ES Monorail PTA Balloon Dilatation Catheter is a cutting-edge medical device designed for minimally invasive vascular procedures. It combines advanced materials and coatings to ensure smooth navigation and effective treatment of peripheral vascular diseases. The catheter's unique coaxial design allows for rapid exchange, making it a versatile tool for interventional cardiologists and radiologists.
1. The Coyote ES catheter features a Bioslide and XTRA Slipcoat coating, which reduces friction and enhances maneuverability during procedures. This ensures smooth passage through narrow and tortuous vessels, minimizing the risk of vessel trauma.
2. The catheter's construction includes a Pebax balloon and a multi-layered shaft made from materials like Vestamid, Grilamid, and stainless steel. This combination provides the necessary flexibility and strength for effective balloon inflation and precise control during angioplasty.
3. The Coyote ES catheter is specifically designed for use in the peripheral vascular system, including arteries like the iliac, femoral, and renal arteries. It is also effective in treating occlusive lesions in dialysis arteriovenous fistulas and is suitable for post-dilation of stents in peripheral vessels.
The Coyote ES Monorail PTA Balloon Dilatation Catheter is a reliable and efficient tool for peripheral vascular interventions. Its advanced coatings and materials ensure smooth navigation and effective treatment, while its coaxial design allows for rapid exchange. Whether treating occlusive lesions or performing post-dilation of stents, this catheter offers precision and versatility.
The Coyote ES Monorail PTA Balloon Dilatation Catheter is designed for precision and efficiency in peripheral vascular interventions. Its key features include advanced coatings, a coaxial design, and a robust construction that ensures smooth navigation and effective treatment.
1. The Bioslide and XTRA Slipcoat coatings reduce friction, allowing the catheter to navigate through narrow and tortuous vessels with ease. This minimizes the risk of vessel trauma and ensures a smoother procedure.
2. The coaxial design of the catheter enables rapid exchange, making it easier for clinicians to switch between devices during complex procedures. This feature enhances procedural efficiency and reduces overall procedure time.
3. The catheter's multi-layered shaft, made from materials like Pebax, Vestamid, and Grilamid, provides the necessary flexibility and strength for effective balloon inflation and precise control during angioplasty.
4. The Coyote ES catheter is compatible with a 0.014in guidewire, allowing for precise placement and navigation through challenging vascular anatomy. This compatibility ensures accurate treatment of target lesions.
5. The catheter is available in various sizes, including 2.00mm-4.00mm balloon diameters, making it suitable for a wide range of peripheral vascular interventions, from angioplasty to stent post-dilation.
The Coyote ES Monorail PTA Balloon Dilatation Catheter stands out for its advanced coatings, rapid exchange design, and robust construction. These features make it an indispensable tool for clinicians performing peripheral vascular interventions, offering precision, efficiency, and versatility in treating a wide range of vascular conditions.
The Coyote ES Monorail PTA Balloon Dilatation Catheter is widely used in clinical settings for the treatment of peripheral vascular diseases. Its applications include angioplasty, stent post-dilation, and the treatment of occlusive lesions in dialysis arteriovenous fistulas.
1. The catheter is primarily used for percutaneous transluminal angioplasty (PTA) in the peripheral vascular system, including the iliac, femoral, and renal arteries. It is effective in treating stenosis and improving blood flow in these vessels.
2. In addition to angioplasty, the Coyote ES catheter is used for post-dilation of peripheral vascular stents. Its 2.00mm-4.00mm balloon sizes are particularly suitable for this application, ensuring optimal stent expansion and vessel patency.
3. The catheter is also used in the treatment of occlusive lesions in natural or synthetic dialysis arteriovenous fistulas. Its precise navigation and effective balloon inflation make it a valuable tool in maintaining fistula patency.
4. The Coyote ES catheter's compatibility with a 0.014in guidewire allows for precise placement in challenging vascular anatomy, making it suitable for complex cases where accuracy is critical.
5. The catheter's advanced coatings and materials ensure minimal vessel trauma during procedures, reducing the risk of complications and improving patient outcomes.
The Coyote ES Monorail PTA Balloon Dilatation Catheter is a versatile tool in the clinical treatment of peripheral vascular diseases. Its applications range from angioplasty to stent post-dilation and the treatment of dialysis fistula occlusions. With its precision and efficiency, it is a trusted choice for clinicians aiming to improve vascular health.
When purchasing the Coyote ES Monorail PTA Balloon Dilatation Catheter, it is important to consider factors such as product specifications, types, budget, and intended use. This guide provides essential information to help make an informed decision.
1. Product specifications: The Coyote ES catheter is available in various sizes, including balloon diameters ranging from 2.00mm to 4.00mm. It is compatible with a 0.014in guidewire and features a coaxial design for rapid exchange.
2. Product types: The catheter is designed for single use and is sterilized with ethylene oxide. It has a shelf life of 3 years and is available in different configurations to suit various clinical needs.
3. Budget considerations: The cost of the Coyote ES catheter may vary depending on the size and quantity purchased. It is important to balance budget constraints with the need for high-quality, reliable medical devices.
4. Usage scenarios: The catheter is suitable for a wide range of peripheral vascular interventions, including angioplasty, stent post-dilation, and the treatment of dialysis fistula occlusions. Understanding the specific clinical needs will help in selecting the appropriate product.
Purchasing the Coyote ES Monorail PTA Balloon Dilatation Catheter requires careful consideration of product specifications, types, budget, and intended use. By understanding these factors, healthcare providers can make informed decisions that ensure the best outcomes for their patients.
When using the Coyote ES Monorail PTA Balloon Dilatation Catheter, it is important to follow specific precautions to ensure patient safety and optimal outcomes. These include proper handling, storage, and adherence to clinical guidelines.
1. Proper handling: The catheter should be handled with care to avoid damage to the balloon or shaft. Ensure that the device is inspected for any defects before use.
2. Storage conditions: The catheter should be stored in a cool, dry place, away from direct sunlight and extreme temperatures. It is important to check the expiration date before use.
3. Sterilization and single use: The Coyote ES catheter is sterilized with ethylene oxide and is intended for single use only. Reuse or reprocessing of the device is strictly prohibited.
4. Clinical guidelines: Follow established clinical protocols for peripheral vascular interventions. Ensure that the catheter is used by trained professionals in appropriate clinical settings.
5. Patient monitoring: During and after the procedure, closely monitor the patient for any signs of complications, such as vessel dissection, thrombosis, or allergic reactions to materials used in the catheter.
Using the Coyote ES Monorail PTA Balloon Dilatation Catheter requires adherence to specific precautions to ensure patient safety and procedural success. Proper handling, storage, and clinical guidelines are essential for achieving the best outcomes. By following these precautions, healthcare providers can minimize risks and enhance the effectiveness of vascular interventions.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.