Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
Coyote MONORAIL PTA Balloon Dilatation Catheters
The Coyote MONORAIL PTA Balloon Dilatation Catheter is an RX-type balloon catheter designed for peripheral vascular interventions. It consists of a tip, balloon, shaft, strain relief, and handle. The balloon is constructed with an outer layer of Vestamid L2101F and an inner layer of Pebax 7233-SA01. The tip and balloon are coated with a hydrophilic coating, while the shaft has a hydrophobic coating. The product is sterilized using ethylene oxide, is for single use, and has a shelf life of three years.
Product English Name:
Coyote MONORAIL PTA Balloon Dilatation Catheters
Alias:
PTA Balloon Catheter,MONORAIL Catheter
Intended Use:
This product is intended for percutaneous transluminal angioplasty (PTA) in the peripheral vascular system, including the iliac, femoral, popliteal, and infrapopliteal arteries, as well as the renal arteries. It is also suitable for treating stenotic lesions in natural or synthetic dialysis arteriovenous fistulas.
Product Introduction

The Coyote MONORAIL PTA Balloon Dilatation Catheter is a specialized medical device designed for minimally invasive vascular procedures. It is engineered to provide precise and controlled dilation of narrowed or blocked blood vessels, facilitating improved blood flow. The catheter's unique design and material composition ensure flexibility, durability, and ease of use, making it a reliable tool for interventional cardiologists and vascular surgeons.

1. The Coyote MONORAIL PTA Balloon Dilatation Catheter features a low-profile design, allowing for easy navigation through tortuous vascular pathways. Its hydrophilic coating on the tip and balloon enhances lubricity, reducing friction during insertion and withdrawal.
2. The catheter's construction includes a multi-layered balloon with an outer layer of Vestamid L2101F and an inner layer of Pebax 7233-SA01, providing excellent flexibility and burst resistance. The shaft is coated with a hydrophobic material to minimize friction and improve handling.
3. This catheter is specifically designed for use in peripheral vascular interventions, including the treatment of stenotic lesions in arteries and dialysis access sites. Its versatility and reliability make it a preferred choice for vascular surgeons.

The Coyote MONORAIL PTA Balloon Dilatation Catheter, also known as the PTA Balloon Catheter or MONORAIL Catheter, is a highly effective tool for vascular interventions. Its advanced design and material composition ensure optimal performance in challenging vascular environments, making it an indispensable device for modern interventional procedures.

Main Features

The Coyote MONORAIL PTA Balloon Dilatation Catheter offers several key features, including a low-profile design, multi-layered balloon construction, and specialized coatings for enhanced performance.

1. The low-profile design of the catheter allows for easy navigation through narrow and tortuous vessels, reducing the risk of vessel trauma.
2. The multi-layered balloon construction provides excellent flexibility and burst resistance, ensuring safe and effective dilation of stenotic lesions.
3. The hydrophilic coating on the tip and balloon enhances lubricity, facilitating smooth insertion and withdrawal of the catheter.
4. The hydrophobic coating on the shaft minimizes friction, improving handling and control during the procedure.
5. The catheter is designed for single use and is sterilized using ethylene oxide, ensuring patient safety and reducing the risk of infection.

The Coyote MONORAIL PTA Balloon Dilatation Catheter is a versatile and reliable device, offering a range of features that enhance its performance in vascular interventions. Its design and material composition make it a preferred choice for interventional cardiologists and vascular surgeons.

Clinical Applications

The Coyote MONORAIL PTA Balloon Dilatation Catheter is widely used in clinical settings for the treatment of peripheral vascular diseases and dialysis access stenoses.

1. The catheter is used in percutaneous transluminal angioplasty (PTA) procedures to treat stenotic lesions in the iliac, femoral, popliteal, and infrapopliteal arteries.
2. It is also employed in the treatment of renal artery stenosis, helping to restore blood flow to the kidneys.
3. The catheter is effective in treating stenotic lesions in natural or synthetic dialysis arteriovenous fistulas, improving dialysis access.
4. Its low-profile design and specialized coatings make it suitable for use in challenging vascular anatomies, including tortuous and calcified vessels.
5. The catheter's versatility and reliability have made it a valuable tool in interventional radiology and vascular surgery.

The Coyote MONORAIL PTA Balloon Dilatation Catheter is a highly effective device for a range of clinical applications, including the treatment of peripheral vascular diseases and dialysis access stenoses. Its advanced design and material composition ensure optimal performance in challenging vascular environments.

Purchasing Guide

When purchasing the Coyote MONORAIL PTA Balloon Dilatation Catheter, it is important to consider product specifications, types, budget, and intended use.

1. Product specifications, including balloon diameter, length, and rated burst pressure, should be carefully evaluated to ensure compatibility with the intended procedure.
2. Different types of catheters are available, including those with varying balloon sizes and coatings, to suit different clinical needs.
3. Budget considerations should include not only the initial purchase cost but also the potential for reduced procedure times and improved patient outcomes.
4. The intended use of the catheter, whether for peripheral vascular interventions or dialysis access procedures, should guide the selection process.

Purchasing the Coyote MONORAIL PTA Balloon Dilatation Catheter requires careful consideration of product specifications, types, budget, and intended use. By selecting the appropriate catheter, healthcare providers can ensure optimal outcomes for their patients.

 Precautions

When using the Coyote MONORAIL PTA Balloon Dilatation Catheter, it is important to follow proper handling and usage guidelines to ensure patient safety and device effectiveness.

1. The catheter should only be used by trained medical professionals familiar with vascular interventions.
2. Proper sterilization and handling techniques should be followed to prevent contamination and infection.
3. The catheter should be inspected for damage or defects before use, and any compromised devices should not be used.
4. The catheter is for single use only and should not be resterilized or reused.
5. Patients should be monitored for adverse reactions during and after the procedure, and appropriate measures should be taken to manage any complications.

The Coyote MONORAIL PTA Balloon Dilatation Catheter is a safe and effective device when used correctly. By following proper handling and usage guidelines, healthcare providers can ensure optimal outcomes for their patients.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files